For applications in hazardous areas
With switching output and analogue output
Scalable analogue output with adjustable span and zero point
Resistant to high-pressure cleaning with aggressive cleaning agents
Clearly visible 4-digit LED display
Specification
Product characteristics
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
|---|---|
| Measuring range | -0.0124...0.25 bar -12.4...250 mbar -5...100.4 inH2O -1.24...25 kPa |
| -0.0124...0.25 bar | -12.4...250 mbar |
| Process connection | threaded connection G 1 external thread sealing cone |
Application
| Special feature | Gold-plated contacts |
|---|---|
| Application | food and beverage industry |
| Installation | freely rotatable housing 350° |
| Media | viscous media and liquids with suspended particles; liquids and gases |
| Medium temperature[°C] [°C] | -20...60; (when used outside the hazardous area:; Ambient temperature: -25...85 °C; Medium temperature: -25...125 °C / 145 °C < 1h) |
| Min. burst pressure | 30000 mbar 12044 inH2O 3000 kPa |
| 30000 mbar | 12044 inH2O |
| Pressure rating | 6000 mbar 2400 inH2O 600 kPa |
| 6000 mbar | 2400 inH2O |
| Type of pressure | relative pressure; vacuum |
Electrical data
| Operating voltage[V] [V] | 18...32 DC |
|---|---|
| Current consumption[mA] [mA] | < 50 |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time[s] [s] | 0.5 |
| Integrated watchdog | yes |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; analogue signal; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 1 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2 |
| Permanent current rating of switching output DC[mA] [mA] | 250 |
| Switching frequency DC[Hz] [Hz] | 6 |
| Number of analogue outputs | 1 |
| Analogue current output[mA] [mA] | 4...20, invertible; (scalable 1:4) |
| Max. load[Ω] [Ω] | (Ub - 10 V) / 20 mA |
| Analogue voltage output[V] [V] | 0...10, invertible; (scalable 1:4) |
| Min. load resistance[Ω] [Ω] | 2000 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Measuring/setting range
| Measuring range | -0.0124...0.25 bar -12.4...250 mbar -5...100.4 inH2O -1.24...25 kPa |
|---|---|
| -0.0124...0.25 bar | -12.4...250 mbar |
| Set point SP | -12...250 mbar -4.8...100.4 inH2O -1.2...25 kPa |
| -12...250 mbar | -4.8...100.4 inH2O |
| Reset point rP | -12.4...249.6 mbar -5...100.2 inH2O -1.24...24.96 kPa |
| -12.4...249.6 mbar | -5...100.2 inH2O |
| Analogue start point | -12.4...187.4 mbar -5...75.2 inH2O -1.24...18.74 kPa |
| -12.4...187.4 mbar | -5...75.2 inH2O |
| Analogue end point | 50...250 mbar 20.1...100.4 inH2O 5...25 kPa |
| 50...250 mbar | 20.1...100.4 inH2O |
| In steps of | 0.2 mbar 0.1 inH2O 0.02 kPa |
| 0.2 mbar | 0.1 inH2O |
Accuracy / deviations
| Switch point accuracy[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1) |
|---|---|
| Repeatability[% of the span] [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) |
| Characteristics deviation[% of the span] [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) |
| Linearity deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Hysteresis deviation[% of the span] [% of the span] | < ± 0,15; (Turn down 1:1) |
| Long-term stability[% of the span] [% of the span] | < ± 0,1; (Turn down 1:1; per year) |
| Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K] | < ± 0,05; (0...70 °C) |
| Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K] | < ± 0,15; (0...70 °C) |
Response times
| Response time[ms] [ms] | < 100 |
|---|---|
| Damping process value dAP[s] [s] | 0.1...100 |
| Damping for the analogue output dAA[s] [s] | 0.1...100 |
| Step response time analogue output[ms] [ms] | 25 |
Software / programming
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span |
|---|
Operating conditions
| Ambient temperature[°C] [°C] | -20...60 |
|---|---|
| Storage temperature[°C] [°C] | -40...100 |
| Protection | IP 65 |
Tests / approvals
| ATEX marking | II 3D Ex tc IIIC T90°C Dc X |
|---|---|
| EMC | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5/1 kV EN 61000-4-6 HF conducted 10 V |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5/1 kV |
| EN 61000-4-6 HF conducted | 10 V |
| Shock resistance | DIN IEC 68-2-27 50 g (11 ms) |
| DIN IEC 68-2-27 | 50 g (11 ms) |
| Vibration resistance | DIN IEC 68-2-6 20 g (10...2000 Hz) |
| DIN IEC 68-2-6 | 20 g (10...2000 Hz) |
| MTTF[years] [years] | 163 |
Mechanical data
| Weight[g] [g] | 509 |
|---|---|
| Housing | cylindrical |
| Dimensions[mm] [mm] | Ø 36 / L = 132 |
| Materials | stainless steel (316L/1.4404); PC; PBT; PEI; FKM; PTFE |
| Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (316L/1.4435); stainless steel (316L/1.4404) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFE; EPDM |
| Min. pressure cycles | 100 million |
| Process connection | threaded connection G 1 external thread sealing cone |
Displays / operating elements
| Display | Display unit 6 x, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit |
|---|---|
| Display unit | mbar; kPa; inH2O; mmWS; % of the span |
| switching status | LED, yellow |
| function display | alphanumeric display, 4-digit |
| measured values | alphanumeric display, 4-digit |
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connector | 1 x M12; coding: A; Contacts: gold-plated |
|---|
Customer Reviews