IFM PE2092

PE2092

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Two switching outputs, one of them programmable as IO-Link and one as analogue output
Red/green display for clear identification of the acceptable range
The process connection can be rotated for optimum alignment
With long-term stability thanks to high overload protection
Robust design for use in harsh industrial environments
Convenient operation via buttons or parameter setting via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0...100 bar
0...1450 psi
0...10 MPa
0...100 bar0...1450 psi
Process connectionthreaded connection G 1/4 internal thread

Application

Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Conditionally suitable foruse in gases at pressures > 25 bar only on request
Medium temperature[°C] [°C]-25...80
Min. burst pressure650 bar
9400 psi
65 MPa
650 bar9400 psi
Pressure rating300 bar
4350 psi
30 MPa
300 bar4350 psi
Vacuum resistance-1000 mbar
-0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 35
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.3
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250
Switching frequency DC[Hz] [Hz]< 500
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable 1:5)
Max. load[Ω] [Ω]500
Analogue voltage output[V] [V]0...10; (scalable 1:5)
Min. load resistance[Ω] [Ω]2000
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0...100 bar
0...1450 psi
0...10 MPa
0...100 bar0...1450 psi
Set point SP0.6...100 bar
10...1450 psi
0.06...10 MPa
0.6...100 bar10...1450 psi
Reset point rP0.2...99.6 bar
4...1444 psi
0.02...9.96 MPa
0.2...99.6 bar4...1444 psi
Analogue start point0...80 bar
0...1160 psi
0...8 MPa
0...80 bar0...1160 psi
Analogue end point20...100 bar
290...1450 psi
2...10 MPa
20...100 bar290...1450 psi
In steps of0.2 bar
2 psi
0.02 MPa
0.2 bar2 psi

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,4; (Turn down 1:1)
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span] [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]0,2; (-25...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]0,2; (-25...80 °C)
Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%

Response times

Response time[ms] [ms]< 1.5
Delay time programmable dS, dr[s] [s]0...50
Damping process value dAP[s] [s]0...4
Damping for the analogue output dAA[s] [s]0...4
Max. response time analogue output[ms] [ms]3

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0
Generic Profiled Sensor
Function
Device identification
Function
Process data variable
Function
Device diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
SIO modeyes
Required master port typeA
Process data analogue1
Process data binary2
Min. process cycle time[ms] [ms]2.3
Supported DeviceIDsdefault
461
default461

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]161
UL approvalUL approval no.
J013
UL approval no.J013
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]253.7
Housingcylindrical
Dimensions[mm] [mm]Ø 34 / L = 90.7
Materialsstainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC
Materials (wetted parts)stainless steel (316L/1.4404); Al2O3 (99.9%; ceramics); EPDM
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 internal thread
Restrictor element integratedno (can be retrofitted)

Displays / operating elements

DisplayDisplay unit
3 x LED, green (bar, psi, MPa)
switching status
2 x LED, yellow
measured values
alphanumeric display, red/green 4-digit
Display unit3 x LED, green (bar, psi, MPa)
switching status2 x LED, yellow
measured valuesalphanumeric display, red/green 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated