Description

Multicode reader with standard lens
Internal infrared illumination
Process interface TCP/IP and EtherNet/IP
Several codes and text lines simultaneously
Integrated memory stick

Specification

Product characteristics

Type of lightinfrared light
Image resolution[px] [px]1280 x 960
Max. reading rate [Hz] [Hz]40

Electrical data

Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]< 300; (24V DC typical)
Max. current consumption[mA] [mA]650; (18V DC, with switched outputs, memory stick active)
Protection classIII
Reverse polarity protectionyes
Overvoltage categoryII
Type of lightinfrared light
Wave length[nm] [nm]850
Image sensorCMOS image sensor black/white

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Inputs

Triggerexternal; 24 V PNP/NPN (IEC 61131-2 Typ 3); TCP/IP; EtherNet/IP; internal

Outputs

Total number of outputs2
Electrical designPNP/NPN; (parameterisable)
Number of digital outputs2; (configurable)
Output functionconfigurable
Max. voltage drop switching output DC[V] [V]1
Max. current load per output[mA] [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Detection zone

Field of view size[mm] [mm]Operating distance
field of view
85
28 x 21
300
92 x 69
500
152 x 114
1000
302 x 227
Operating distancefield of view
8528 x 21
30092 x 69
500152 x 114
1000302 x 227
Operating distance[mm] [mm]> 85
Image resolution[px] [px]1280 x 960
Lens typestandard
Readable codesInterleaved 2-of-5; Industrial 2-of-5; Code 39; Code 93; Code 128; Pharmacode; Codabar; EAN8; EAN8 Add-On 2; EAN8 Add-On 5; EAN13; EAN13 Add-On 2; EAN13 Add-On 5; UPC-A; UPC-A Add-On 2; UPC-A Add-On 5; UPC-E; UPC-E Add-On 2; UPC-E Add-On 5; GS1 DataBar Omnidirectional; GS1 DataBar Truncated; GS1 DataBar Stacked; GS1 DataBar Stacked Omnidirectional; GS1 DataBar Limited; GS1 DataBar Expanded; GS1 DataBar Expanded Stacked; GS1 - 128; MSI Barcode; ECC200; PDF-417; QR; Micro-QR; Aztec Code; GS1 ECC200; GS1 QR Code; GS1 Aztec Code
Code quality based onISO / IEC 15415
ISO / IEC 15416
AIM DPM
ISO/IEC TR 29158
SEMI T10
Legible fontsIndustrial; Document; OCR-A; OCR-B; Pharma; Semi; Universal; Dot Print
Text recognitionyes
Omnidirectional readingyes
Max. inclination to the image plane[°] [°]45
Max. reading rate [Hz] [Hz]40

Software / programming

Parameter setting optionsteach button; via PC with ifm Vision Assistant

Interfaces

Communication interfaceEthernet
Number of Ethernet interfaces1
Transmission standard10Base-T; 100Base-TX
Transmission rate10 MBit/s; 100 MBit/s
ProtocolTCP/IP; EtherNet/IP
Factory settingsIP address: 192.168.0.69
subnet mask: 255.255.255.0 (Class C)
gateway IP address: 192.168.0.201
MAC address: see type label
Usage typeparameter setting; data transmission

Operating conditions

Ambient temperature[°C] [°C]-10...50
Storage temperature[°C] [°C]-40...70
Max. relative air humidity[%] [%]90; (non condensing)
Max. height above sea level[m] [m]4000
ProtectionIP 65
Pollution degree3

Tests / approvals

EMCEN IEC 61000-6-4 radiation of interference
industrial environments
EN IEC 61000-6-2 immunity
industrial environments
EN IEC 61000-6-4 radiation of interferenceindustrial environments
EN IEC 61000-6-2 immunityindustrial environments
Shock resistanceEN 60068-2-27
50 g 11 ms / not repetitive
EN 60068-2-27
40 g 6 ms / repetitive
EN 60068-2-2740 g 6 ms / repetitive
Vibration resistanceEN 60068-2-6
2 g (10 ... 150 Hz)
EN 60068-2-62 g (10 ... 150 Hz)
Laser protection class1
Notes on laser protectionCaution:
laser light
laser class:
1
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040.10 except for compliance with IEC 60825-1 Ed. 3, as described in Laser Notice No. 56 dated 8 May 2019.
Caution:laser light
laser class:1
Photobiological safetyexempt group; (EN 62471)
Electrical safetyEN IEC 61010-2-201
electrical supply only via PELV circuits
EN IEC 61010-2-201electrical supply only via PELV circuits
MTTF[years] [years]53
UL approvalTa
-10...50 °C
Enclosure type
1
power supply
Limited Energy
File number UL
E364788
Ta-10...50 °C
Enclosure type1
power supplyLimited Energy
File number ULE364788

Mechanical data

Weight[g] [g]599.5
Type of mountingscrew mounting; (bore hole M4 x 7 mm)
Dimensions[mm] [mm]45 x 45 x 96
Materialshousing: diecast zinc powder-coated; front pane: gorilla glass; LED window: PC; pushbutton: POM
Sealing materialFKM
Tightening torque[Nm] [Nm]2.1

Displays / operating elements

Displayfunction
2 x LED, green
function
2 x LED, yellow
Teach-Funktion
1 x LED, green
Teach-Funktion
1 x LED, yellow
function2 x LED, yellow
Teach-Funktion1 x LED, yellow
Operating elements1 x
Teach-Taste
1 xTeach-Taste

Accessories

Accessories (optional)Operating software
Mounting accessories
Adapter cable
protective panes and filter panes

Remarks

Pack quantity1 pcs.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM O2I501”

Your email address will not be published. Required fields are marked *