IFM MFH219
MFH219
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Adjustable end position monitoring in the hydraulic cylinder
Inline quality control checks to ensure correct assembly of parts
Monitoring of critical hydraulic cylinders via switching cycles counter
High-pressure resistant up to an operating pressure of 500 bar
User-friendly communication and parameterisation via IO-Link
Specification
Product characteristics
| Electrical design | PNP/NPN |
|---|---|
| Output function | normally open / normally closed; (parameterisable) |
| Sensing range[mm] [mm] | 0...2; (Factory setting: 1,65) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M12 x 1 / L = 55 |
Application
| Special feature | Full-metal housing |
|---|---|
| Application | hydraulic cylinders |
| Media | detects ferrous metals |
| Min. burst pressure | 2000 bar 200 MPa |
| 2000 bar | 200 MPa |
| Pressure rating | 500 bar 50 MPa |
| 500 bar | 50 MPa |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
|---|---|
| Rated insulation voltage[V] [V] | 60 |
| Current consumption[mA] [mA] | > 25 |
| Protection class | III |
| Reverse polarity protection | yes |
| Max. power-on delay time[ms] [ms] | 300 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Electrical design | PNP/NPN |
|---|---|
| Number of digital outputs | 2 |
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 1.6 |
| Max. leakage current[mA] [mA] | 0.1 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 200 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 0...2; (Factory setting: 1,65) |
|---|
Accuracy / deviations
| Hysteresis[mm] [mm] | 0.05...0.5; (Factory setting: 0,1) |
|---|---|
| Switch point drift[% of Sr] [% of Sr] | 10 |
| Repeatability[% of Sr] [% of Sr] | 10 |
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1.3 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 4.1.1 Measuring and Switching Sensor, 1 channel Common - I&D Identification and Diagnosis Extension Object detection, switches when value falls below the setpoint Function Locator Function ProductURI Function Teach channel |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel |
| Common - I&D | Identification and Diagnosis |
| Extension | Object detection, switches when value falls below the setpoint |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 4 |
| Supported DeviceIDs | default 1905 |
| default | 1905 |
Operating conditions
| Pressure peak[bar] [bar] | 1000 |
|---|---|
| Ambient temperature[°C] [°C] | -25...85 |
| Protection | IP 65; IP 67; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 (80...2000 Mhz) 10 V/m EN 61000-4-4 2 kV EN 61000-4-6 (0,15...80 Mhz) 10 V EN 55011 class B DIN ISO 11452-5 100 V/m |
|---|---|
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 (80...2000 Mhz) | 10 V/m |
| EN 61000-4-4 | 2 kV |
| EN 61000-4-6 (0,15...80 Mhz) | 10 V |
| EN 55011 | class B |
| DIN ISO 11452-5 | 100 V/m |
| Vibration resistance | EN 60068-2-6 Fc 20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C |
| EN 60068-2-6 Fc | 20 g 50 sweep cycles, 1 octave per minute, in 3 axes / 10...3000 Hz -20...50 °C |
| Shock resistance | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| EN 60068-2-27 Ea | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Continuous shock resistance | EN 60068-2-27 Ea 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Salt spray test | EN 60068-2-52 Kb severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
| UL approval | Ta -25...65 °C Enclosure type Type 1 power supply Limited Voltage/Current UL approval no. C025 File number UL E174191 |
| Ta | -25...65 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | C025 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 94.2 |
|---|---|
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M12 x 1 / L = 55 |
| Thread designation | M12 x 1 |
| Materials | housing: stainless steel (316L / 1.4404); O-ring: FPM; supporting ring: PTFE; plug: PEI |
| Min. pressure cycles | 10 million |
| Tightening torque[Nm] [Nm] | < 25 |
| Full-metal housing | yes |
Displays / operating elements
| Display | switching status LED, yellow |
|---|---|
| switching status | LED, yellow |
Accessories
| Items supplied | lock nuts: 1 x M12 |
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Cable | 2 m, PUR, Ø 4.9 mm; 4 x 0.34 mm² |
|---|