Fast delivery within 72 Hours

IFM LMH600

LMH600

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

For the reliable level control in tanks and containers
Hygienegerechtes Design für die Anforderungen in der Lebensmittel- und Pharmaindustrie
Use in liquid and viscous media and bulk materials
Reliable suppression of deposits or foam
For use in high temperatures
User-friendly communication and parameterisation via IO-Link
Temperature as an additional process value via IO-Link

Specification

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Factory settinghydrous media
Process connectionthreaded connection G 1/2

Application

Special featureGold-plated contacts
MediaLiquids; viscous media; powder
Conditionally suitable foruse at pressures > 40…100 bar only on request
Cannot be used forSee the operating instructions, chapter "Function and features".
Medium temperature[°C] [°C]when used under hygienic conditions with accessories: E43030
-15...240
when used under hygienic conditions with accessories: E43033
-15...200
when used under hygienic conditions with accessories: E43031
-40...150
when used under industrial conditions with accessories: E43032
-40...250
when used under hygienic conditions with accessories: E43030-15...240
when used under hygienic conditions with accessories: E43033-15...200
when used under hygienic conditions with accessories: E43031-40...150
when used under industrial conditions with accessories: E43032-40...250
Pressure rating[bar] [bar]40
Vacuum resistance[mbar] [mbar]-1000
Probe length[mm] [mm]13.7

Electrical data

Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]< 30
Protection classIII
Reverse polarity protectionyes
Measuring principlecapacitive

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal; IO-Link
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]100
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Factory settinghydrous media
Measuring range[°C] [°C]-40...250
Resolution[°C] [°C]0.1

Accuracy / deviations

Accuracy[K] [K]± 0,6
Temperature drift per 10 K[K] [K]± 0.055

Response times

Response time[s] [s]< 0.5
Response time T50[s] [s]< 15; (water)
Response time T90[s] [s]< 60; (water)

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 4.1.2
Measuring and Switching Sensor, 2 channel
Common - I&D
Identification and Diagnosis
Extension
Quantity detection, switches when value exceeds the setpoint
Function
Locator
Function
ProductURI
Smart Sensor - SSP 4.1.2Measuring and Switching Sensor, 2 channel
Common - I&DIdentification and Diagnosis
ExtensionQuantity detection, switches when value exceeds the setpoint
FunctionProductURI
SIO modeyes
Required master port typeA
Min. process cycle time[ms] [ms]4.5
Supported DeviceIDsdefault
1475
default1475

Operating conditions

Ambient temperature[°C] [°C]-40...85
Note on ambient temperatureMedium temperature: ≤ 200 °C
-40...60 °C
Medium temperature: ≤ 250 °C
Storage temperature[°C] [°C]-40...85
ProtectionIP 68; IP 69K; (7 days / 3 m water depth / 0.3 bar: IP68)

Tests / approvals

EMCDIN EN 61000-6-2
DIN EN 61000-6-4
: in plastic or open metal tanks
DIN EN 61000-6-3
: in a closed metal tank
DIN EN 61000-6-4: in plastic or open metal tanks
DIN EN 61000-6-3: in a closed metal tank
Shock resistanceDIN EN 60068-2-27
50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6
20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]356

Mechanical data

Weight[g] [g]0.001
Housingcylindrical
Dimensions[mm] [mm]Ø 30 / L = 169
Materialshousing: stainless steel (316L/1.4404); Adapter plug: PEI; O-ring: FKM blue
Materials (wetted parts)probe: ceramics (99.97 % Al2O3) surface characteristics: Ra < 0,38 µm / Rz = 4 µm; O-ring: FFKM grey
Process connectionthreaded connection G 1/2

Displays / operating elements

Displayswitching status
LED, yellow
operating status
LED, green
warning
LED, red
switching statusLED, yellow
operating statusLED, green
warningLED, red

Accessories

Accessory requiredsealing set, E43030
sealing set, E43033
sealing set, E43031
Gasket, E43032

Remarks

RemarksAn overview of the materials, approvals and conformities of the accessories can be found in the respective data sheet.
The E43031 sealing kit slightly increases the sensor sensitivity
see operating instructions
NotesTo ensure secure mounting compatible with the medium, a sealing set suitable for the application must be used. Please refer to chapters Medium temperature and Accessories.; These sealing sets are not included.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM LMH600”

Your email address will not be published. Required fields are marked *