Fast delivery within 72 Hours
IFM KI001A
KI001A
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
For applications in hazardous areas
With combined AC/DC output stage
Easy setting of the sensing range via potentiometer
Two-wire technology
Output function normally open / normally closed programmable
Specification
Product characteristics
| Output function | normally open / normally closed; (selectable) |
|---|---|
| Sensing range[mm] [mm] | 15 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 125 |
Electrical data
| Operating voltage[V] [V] | 30...250 AC / 20...250 DC |
|---|---|
| Protection class | II |
| Reverse polarity protection | yes |
| Measuring principle | capacitive |
Outputs
| Output function | normally open / normally closed; (selectable) |
|---|---|
| Max. voltage drop switching output DC[V] [V] | 8 |
| Max. voltage drop switching output AC[V] [V] | 10 |
| Minimum load current[mA] [mA] | 5 |
| Max. leakage current[mA] [mA] | 2.5 (250 V AC) / 1.7 (110 V AC) / 1.5 (24 V DC) |
| Permanent current rating of switching output AC[mA] [mA] | 100; (150 (...40 °C)) |
| Permanent current rating of switching output DC[mA] [mA] | 100; (150 (...40 °C)) |
| Short-time current rating of switching output[mA] [mA] | 1000; (20ms / 0,5Hz) |
| Switching frequency AC[Hz] [Hz] | 10 |
| Switching frequency DC[Hz] [Hz] | 10 |
| Notes on switching frequency[Hz] [Hz] | only for resistive loads; 2 Hz for utilisation category AC-140 |
| Short-circuit proof | no |
| Overload protection | no |
Detection zone
| Sensing range[mm] [mm] | 15 |
|---|---|
| Sensing range adjustable | yes |
| Factory setting sensing range[mm] [mm] | 15 |
| Real sensing range Sr[mm] [mm] | 15 ± 10 % |
Accuracy / deviations
| Correction factor | glass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2 |
|---|---|
| Hysteresis[% of Sr] [% of Sr] | 1...15 |
| Switch point drift[% of Sr] [% of Sr] | -20...20 |
Operating conditions
| Ambient temperature[°C] [°C] | -20...60 |
|---|---|
| Protection | IP 65; IP 67 |
Tests / approvals
| ATEX marking | II 3D Ex tc IIIC T90°C Dc |
|---|---|
| EMC | EN 61000-4-2 ESD kV / 8 kV AD EN 61000-4-3 HF radiated 3 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 1 kV line to line, Ri: 2 Ohm EN 61000-4-6 HF conducted 3 V EN 55011 class B |
| EN 61000-4-2 ESD | kV / 8 kV AD |
| EN 61000-4-3 HF radiated | 3 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 1 kV line to line, Ri: 2 Ohm |
| EN 61000-4-6 HF conducted | 3 V |
| EN 55011 | class B |
| MTTF[years] [years] | 305 |
Mechanical data
| Weight[g] [g] | 156.5 |
|---|---|
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 125 |
| Thread designation | M30 x 1.5 |
| Materials | PBT; PA |
Displays / operating elements
| Display | switching status 1 x LED, yellow |
|---|---|
| switching status | 1 x LED, yellow |
Electrical connection
| Required protection | miniature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area. |
|---|
Accessories
| Items supplied | lock nuts: 2 |
|---|
Remarks
| Remarks | Recommendation: Check the safe functioning of the unit after a short circuit. |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| terminals | 0.34...2.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5 |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0