Fast delivery within 72 Hours
IFM II6913
II6913
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Precise linearised output signal
Very high repeatability
For non-contact distance measurement
Wide operating temperature range
Robust metal housing for use in harsh industrial environments
User-friendly communication and parameterisation via IO-Link
Specification
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
|---|---|
| Output function | normally open / normally closed; (parameterisable) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 65 |
Electrical data
| Operating voltage[V] [V] | 15...30 DC |
|---|---|
| Current consumption[mA] [mA] | < 30 |
| Protection class | II |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
|---|---|
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 300 |
| Analogue current output[mA] [mA] | 4...20; (linear; gradient: 1,143 mA/mm; for frontal approach and for target made of mild steel: 45 x 45 x 1 mm) |
| Max. load[Ω] [Ω] | 500; (Ub <=18 V;; Max. load <=400 Ω) |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Measuring range[mm] [mm] | 1...15 |
|---|---|
| Switch point IO-Link[mm] [mm] | 2.37...13.99 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3 |
|---|---|
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
| Note on hysteresis | parameterisable |
| Linearity error of analogue output[%] [%] | ± 1; (of the final value of the measuring range) |
| Repeatability analogue output[%] [%] | ± 1; (of the final value of the measuring range) |
| Temperature coefficient[%/K vom MEW] [%/K vom MEW] | ±0,15 |
| Temperature drift | ± 5 %; (of the final value of the measuring range) |
Response times
| Response time[ms] [ms] | < 10 |
|---|
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0 Generic Profiled Sensor Common - I&D Identification and Diagnosis Function Multiple switching signal Function Teach channel |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Common - I&D | Identification and Diagnosis |
| Function | Teach channel |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| IO-Link process data (cyclical) | process value 16 device status 4 binary switching information 2 |
| process value | 16 |
| device status | 4 |
| binary switching information | 2 |
| IO-Link functions (acyclical) | switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag |
| Supported DeviceIDs | default 1205 |
| default | 1205 |
| Note | For further information please see the IODD PDF file under "Downloads" |
Operating conditions
| Ambient temperature[°C] [°C] | -25...80 |
|---|---|
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B |
|---|---|
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na TA = -25°C; TB = 80°C; t1 = 30 min; t2 = < 10 s 50 cycles |
| EN 60068-2-14 Na | TA = -25°C; TB = 80°C; t1 = 30 min; t2 = < 10 s 50 cycles |
| MTTF[years] [years] | 522 |
| Embedded software included | yes |
| UL approval | Ta -25...60 °C Enclosure type Type 1 power supply Limited Voltage/Current UL approval no. A023 File number UL E174191 |
| Ta | -25...60 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A023 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 113 |
|---|---|
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | M30 x 1.5 / L = 65 |
| Thread designation | M30 x 1.5 |
| Materials | housing: brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated |
| Tightening torque[Nm] [Nm] | 50 |
Displays / operating elements
| Display | target in measuring range 4 x LED, yellow lights target outside measuring range 4 x LED, yellow flashing |
|---|---|
| target in measuring range | 4 x LED, yellow lights |
| target outside measuring range | 4 x LED, yellow flashing |
Accessories
| Items supplied | lock nuts: 2 |
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection - plug
| Connector | 1 x M12; coding: A |
|---|