Specification
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
|---|---|
| Output function | normally open / normally closed; (parameterisable) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
Application
| Special feature | Full-metal housing |
|---|---|
| Application | Use in hygienic areas / regular cleaning processes |
| Pressure rating | 100 bar 10 MPa |
| 100 bar | 10 MPa |
| Note on pressure rating | sensing face |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
|---|---|
| Current consumption[mA] [mA] | < 15 |
| Protection class | III |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
|---|---|
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 100 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Switch point IO-Link[mm] [mm] | 1.41...7.01; (parameterisable) |
|---|---|
| Measuring range IO-Link[mm] [mm] | 0.75...7.5 |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.8 / brass: 0.5 / aluminium: 0.4 / copper: 0.2 |
|---|---|
| Hysteresis[% of Sr] [% of Sr] | 3...15 |
| Linearity error IO-Link[%] [%] | ± 2; (of the final value of the measuring range) |
| Repeatability IO-Link[%] [%] | ± 1; (of the final value of the measuring range) |
| Temperature coefficient | ± 0,2 %/K; (of the final value of the measuring range) |
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 |
| Profiles | Smart Sensor - SSP 0 Generic Profiled Sensor Function Multiple switching signal Function Teach channel Common - I&D Identification and Diagnosis |
| Smart Sensor - SSP 0 | Generic Profiled Sensor |
| Function | Teach channel |
| Common - I&D | Identification and Diagnosis |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default 1090 |
| default | 1090 |
Operating conditions
| Ambient temperature[°C] [°C] | 0...100 |
|---|---|
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 class B |
|---|---|
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Impact resistance | 1 J |
| Vibration resistance | EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Nc TA = 0°C; TB = 100°C; t1 = 30 min; t2 = < 10 s 50 cycles |
| EN 60068-2-14 Nc | TA = 0°C; TB = 100°C; t1 = 30 min; t2 = < 10 s 50 cycles |
| Salt spray test | EN 60068-2-52 Kb severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
| MTTF[years] [years] | 635 |
| Embedded software included | yes |
| UL approval | Ta -25...70 °C Enclosure type Type 1 power supply Limited Voltage/Current UL approval no. A008 File number UL E174191 |
| Ta | -25...70 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A008 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 51.1 |
|---|---|
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M18 x 1 / L = 60 |
| Thread designation | M18 x 1 |
| Materials | housing: stainless steel (316L/1.4404); sensing face: stainless steel (316L/1.4404); LED window: PEI; lock nuts: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 50 |
| Full-metal housing | yes |
Displays / operating elements
| Display | switching status 4 x LED, yellow |
|---|---|
| switching status | 4 x LED, yellow |
Accessories
| Items supplied | lock nuts: 2 |
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Connector | 1 x M12; coding: A |
|---|