E1 type approval by the Kraftfahrt-Bundesamt (German Federal Motor Transport Authority)
Wide operating temperature range
High ingress protection for the requirements of harsh environmental conditions
High EMC resistance according to automotive standards
Large operating voltage range
Specification
Product characteristics
| Electrical design | PNP/NPN |
|---|---|
| Output function | normally open |
| Sensing range[mm] [mm] | 12 |
| Housing | threaded type |
| Dimensions[mm] [mm] | M18 x 1 / L = 81 |
Application
| Special feature | Increased sensing range |
|---|---|
| Application | Use in mobile and harsh applications |
Electrical data
| Operating voltage[V] [V] | 10...36 DC |
|---|---|
| Current consumption[mA] [mA] | < 10; (only in 3-wire operation) |
| Protection class | II |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN |
|---|---|
| Output function | normally open |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Minimum load current[mA] [mA] | 2; (only in 2-wire operation) |
| Max. leakage current[mA] [mA] | 0.5; (only in 2-wire operation) |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 200 |
| Short-circuit protection | yes |
| Type of short-circuit protection | pulsed |
| Overload protection | yes |
Detection zone
| Sensing range[mm] [mm] | 12 |
|---|---|
| Real sensing range Sr[mm] [mm] | 12 ± 10 % |
| Operating distance[mm] [mm] | 0...9.72 |
| Increased sensing range | yes |
Accuracy / deviations
| Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.45 / copper: 0.35 |
|---|---|
| Hysteresis[% of Sr] [% of Sr] | 1...20 |
| Switch point drift[% of Sr] [% of Sr] | -10...10 |
Operating conditions
| Ambient temperature[°C] [°C] | -40...85 |
|---|---|
| Protection | IP 67; IP 69K |
Tests / approvals
| EMC | automotive area noise emission and noise immunity: ECE R10 E1 type approval noise immunity according to DIN ISO 11452-2 100 V/m conducted interference in 24 V networks to ISO 7637-2: 2004 (pulse 1 to 4) and ISO16750-2: 2012 (load dump) pulse 1 2a 2b 3a 3b 4 Load dump severity level III III III III III III Test A failure criterion C A C A A C C EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-5 Surge 0,5 kV mains line to line EN 61000-4-6 HF conducted 10 V EN 55011 class B |
|---|---|
| noise emission and noise immunity: ECE R10 | E1 type approval |
| noise immunity according to DIN ISO 11452-2 | 100 V/m |
| pulse | 1 2a 2b 3a 3b 4 Load dump |
| severity level | III III III III III III Test A |
| failure criterion | C A C A A C C |
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-5 Surge | 0,5 kV mains line to line |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | class B |
| Vibration resistance | EN 60068-2-6 Fc 20 g (10...3000 Hz) / -20...50 °C 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / -20...50 °C |
| Shock resistance | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes / -40...85 °C |
| Continuous shock resistance | EN 60068-2-27 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| EN 60068-2-27 | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes / -20...50 °C |
| Fast temperature change | EN 60068-2-14 Na TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| Salt spray test | EN 60068-2-52 Kb severity level 5 (4 test cycles) |
| EN 60068-2-52 Kb | severity level 5 (4 test cycles) |
| MTTF[years] [years] | 1195 |
| UL approval | Ta 0...40 °C Enclosure type Type 1 File number UL E174191 |
| Ta | 0...40 °C |
| Enclosure type | Type 1 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 307 |
|---|---|
| Housing | threaded type |
| Mounting | non-flush mountable |
| Dimensions[mm] [mm] | M18 x 1 / L = 81 |
| Thread designation | M18 x 1 |
| Materials | housing: stainless steel; sensing face: LCP natural; LED window: PEI; lock nuts: brass |
Displays / operating elements
| Display | switching status 4 x 90° LED, yellow |
|---|---|
| switching status | 4 x 90° LED, yellow |
Accessories
| Items supplied | lock nuts: 2 |
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection
| Cable | 6 m, PUR, Ø 5.4 mm; burning behaviour to ECE R118 rev. 2; 3 x 0.5 mm² |
|---|