Specification
Product characteristics
| Electrical design | PNP/NPN; (parameterisable) |
|---|---|
| Output function | normally open / normally closed; (parameterisable) |
| Communication interface | IO-Link |
| Housing | threaded type |
| Dimensions[mm] [mm] | M8 x 1 / L = 60 |
Application
| Special feature | Gold-plated contacts; Magnetic-field immune |
|---|---|
| Magnetic-field immune | yes |
| Max. magnetic field immunity[mT] [mT] | 300 |
Electrical data
| Operating voltage[V] [V] | 10...30 DC |
|---|---|
| Current consumption[mA] [mA] | < 20 |
| Protection class | III |
| Reverse polarity protection | yes |
Outputs
| Electrical design | PNP/NPN; (parameterisable) |
|---|---|
| Output function | normally open / normally closed; (parameterisable) |
| Max. voltage drop switching output DC[V] [V] | 2.5 |
| Permanent current rating of switching output DC[mA] [mA] | 100 |
| Switching frequency DC[Hz] [Hz] | 75 |
| Short-circuit protection | yes |
| Overload protection | yes |
Detection zone
| Switch point IO-Link[mm] [mm] | 0.05...1.455 |
|---|---|
| Measuring range IO-Link[mm] [mm] | 0.05...1.5 |
Accuracy / deviations
| Repeatability | < 10 µm |
|---|---|
| Resolution[µm] [µm] | 5 |
| Temperature drift | ± 1,5 µm/K |
| Linearity deviation | ± 50 µm |
Interfaces
| Communication interface | IO-Link |
|---|---|
| Transmission type | COM2 (38,4 kBaud) |
| IO-Link revision | 1.1 |
| SDCI standard | IEC 61131-9 CDV |
| Profiles | Smart Sensor - SSP 4.1.1 Measuring and Switching Sensor, 1 channel Common - I&D Identification and Diagnosis Extension Object detection, switches when value falls below the setpoint Function Locator Function ProductURI |
| Smart Sensor - SSP 4.1.1 | Measuring and Switching Sensor, 1 channel |
| Common - I&D | Identification and Diagnosis |
| Extension | Object detection, switches when value falls below the setpoint |
| Function | ProductURI |
| SIO mode | yes |
| Required master port type | A |
| Min. process cycle time[ms] [ms] | 3.2 |
| Supported DeviceIDs | default 1815 |
| default | 1815 |
Operating conditions
| Ambient temperature[°C] [°C] | -25...70 |
|---|---|
| Protection | IP 65; IP 66; IP 67; IP 68; IP 69K |
Tests / approvals
| EMC | EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V EN 55011 Class A |
|---|---|
| EN 61000-4-2 ESD | 4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated | 10 V/m |
| EN 61000-4-4 Burst | 2 kV |
| EN 61000-4-6 HF conducted | 10 V |
| EN 55011 | Class A |
| Vibration resistance | EN 60068-2-6 Fc 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| EN 60068-2-6 Fc | 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes |
| Shock resistance | EN 60068-2-27 Ea 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Ea | 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes |
| Continuous shock resistance | EN 60068-2-27 Eb 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| EN 60068-2-27 Eb | 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes |
| Fast temperature change | EN 60068-2-14 Na TA = -25 °C; TB = 70 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| EN 60068-2-14 Na | TA = -25 °C; TB = 70 °C; t1 = 30 min; t2 = < 10 s; 50 cycles |
| MTTF[years] [years] | 1347 |
| Embedded software included | yes |
| UL approval | Ta -25...70 °C Enclosure type Type 1 power supply Limited Voltage/Current UL approval no. A031 File number UL E174191 |
| Ta | -25...70 °C |
| Enclosure type | Type 1 |
| power supply | Limited Voltage/Current |
| UL approval no. | A031 |
| File number UL | E174191 |
Mechanical data
| Weight[g] [g] | 46.8 |
|---|---|
| Housing | threaded type |
| Mounting | flush mountable |
| Dimensions[mm] [mm] | M8 x 1 / L = 60 |
| Thread designation | M8 x 1 |
| Materials | housing: stainless steel (316L/1.4404); sensing face: LCP white; LED window: PPSU; lock nuts: stainless steel (316L/1.4404) |
| Tightening torque[Nm] [Nm] | 7 |
Displays / operating elements
| Display | switching status 4 x LED, yellow SIO mode output stage supplied with current LED, yellow lights IO-Link mode target in measuring range LED, yellow lights |
|---|---|
| switching status | 4 x LED, yellow |
| output stage supplied with current | LED, yellow lights |
| target in measuring range | LED, yellow lights |
Accessories
| Items supplied | lock nuts: 2 |
|---|
Remarks
| Pack quantity | 1 pcs. |
|---|
Electrical connection - plug
| Connector | 1 x M8; coding: A; Locking: snap-fit ; Contacts: gold-plated |
|---|