Fast delivery within 72 Hours

IFM GG854S

GG854S

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Certified to the following standards: EN 60947-5-3, IEC 61508 and ISO 13849
Connection to safety PLC, safe AS-i modules or safe evaluation units
Ensuring operator and machine safety

Specification

Product characteristics

Electrical designPNP
Output function2 x OSSD (A1 and A2)
Enable zone[mm] [mm]> 11.5
Housingthreaded type
Dimensions[mm] [mm]M18 x 1 / L = 60

Application

Special featureGold-plated contacts
Type of operationpermanent operation
Safety-related sub-functionsafe state when damped correctly
ApplicationUse in mobile and harsh applications

Electrical data

Operating voltage[V] [V]8...32 DC
Rated insulation voltage[V] [V]60
Current consumption[mA] [mA]< 20
Protection classIII
Reverse polarity protectionyes
Max. power-on delay time[ms] [ms]1000

Outputs

Electrical designPNP
Output function2 x OSSD (A1 and A2)
Max. voltage drop switching output DC[V] [V]2.5; (30 mA)
Minimum load current[mA] [mA]1
Permanent current rating of switching output DC[mA] [mA]50
Switching frequency DC[Hz] [Hz]10
Output dataInterface type C class 1
Output voltage at 24 Vcompatible with EN 61131-2 inputs type 1, 2
Short-circuit protectionyes
Overload protectionyes
Max. capacitive load CL_max[nF] [nF]20

Detection zone

Enable zone[mm] [mm]> 11.5
Safe switch-off distance s(ao)[mm] [mm]< 6.5

Accuracy / deviations

Correction factorsteel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.4 / copper: 0.3
Hysteresis[% of Sr] [% of Sr]1...10

Response times

Response time to safety request[ms] [ms]5
Response time when approaching the enable zone[ms] [ms]5
Risk time (response time for safety-related faults)[ms] [ms]100

Operating conditions

Ambient temperature[°C] [°C]-40...85
Max. relative air humidity[%] [%]50; (70 °C; <70 °C: >50 %)
Max. height above sea level[m] [m]5000
Ionising radiationnot permissible
ProtectionIP 65; IP 67; IP 68; IP 69K; (with ifm socket duly screwed on)
Chemical mediatest according to ISO 16750-5
the following media were tested for 22 hours at 60 °C
coolants
(HoughtonHocut4480
Oemeta
HYCUT ET 46)
The following media were tested for 22 hours at 75 °C
hydraulic fluids
(Fuchs Renoling B15 VG 46 HLP
Total BiohydranTMP 4HEES
Fuchs Hydrotherm 46 M HFC)
transmission oils
(Fuchs TITAN ATF 3353 Dexron III)
diesel
biodiesel
urea
(AdBlue)
brake fluid
(K2 TURBO DOT 4)
the following media were tested for 22 hours at 23 °C
corrosion protection
(Sonax special preservation wax )
cold cleaner
(Sonax cold cleaner S )
ammonia-based cleaner
(Weco Dr. Webers Salmiak-Konzentrat (concentrated ammonium chloride) )
battery acid
the following media were tested for 2 hours at 23 °C
wheel rim cleaner
(Sonax Xtreme Plus)
the following media were tested for 10 minutes at 23 °C
premium-grade petrol lead-free
the following media were tested for 22 hours at 60 °Ccoolants
The following media were tested for 22 hours at 75 °Chydraulic fluids
the following media were tested for 22 hours at 23 °Ccorrosion protection
the following media were tested for 2 hours at 23 °Cwheel rim cleaner
the following media were tested for 10 minutes at 23 °Cpremium-grade petrol lead-free

Tests / approvals

EMCindustrial environments
EN 60947-5-3
EN 61000-4-2 ESD
6 kV CD / 8 kV AD
EN 61000-4-3 HF radiated
20 V/m
EN 61000-4-4 Burst
2 kV
EN 61000-4-5 Surge
2 kV
EN 61000-4-6 HF conducted
10 V
EN 61000-4-8
30 A/m 50/60 Hz / 1000 A/m 0 Hz
EN 55011
class B
mobile applications
only for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems
ISO 10605 ESD
8 kV CD / 15 kV AD
ISO 11452-2, ISO 11452-5 radiated immunity
100 V/m
ISO 7637-2, ISO 16750-2 conducted immunity
12 V / 24 V
pulse
1 2a 3a 3b 4 5b
severity level
III III III III III III 58V
failure criterion
B B B A A C/B A
EN 55025
EN 61000-4-2 ESD6 kV CD / 8 kV AD
EN 61000-4-3 HF radiated20 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-5 Surge2 kV
EN 61000-4-6 HF conducted10 V
EN 61000-4-830 A/m 50/60 Hz / 1000 A/m 0 Hz
EN 55011class B
mobile applicationsonly for operation with central load-dump suppression (58 V) / not for active operation during motor start phase in 12 V systems
ISO 10605 ESD8 kV CD / 15 kV AD
ISO 11452-2, ISO 11452-5 radiated immunity100 V/m
ISO 7637-2, ISO 16750-2 conducted immunity12 V / 24 V
pulse1 2a 3a 3b 4 5b
severity levelIII III III III III III 58V
failure criterionB B B A A C/B A
Vibration resistanceEN 60068-2-6 Fc
20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes
EN 60068-2-6 Fc20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes
Broadband noiseEN 60068-2-64 h
5,9 g (10...2000 Hz) / effective acceleration for chassis mounting
EN 60068-2-64 h5,9 g (10...2000 Hz) / effective acceleration for chassis mounting
Shock resistanceEN 60068-2-27 Ea
100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
EN 60068-2-27 Ea40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Continuous shock resistanceEN 60068-2-27 Ea
40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature changeEN 60068-2-14 Na
TA = -40°C; TB = 85°C; t1 = 30 min; t2 = 10 s 100 cycles
EN 60068-2-14 NaTA = -40°C; TB = 85°C; t1 = 30 min; t2 = 10 s 100 cycles
Salt spray testEN 60068-2-52 Kb
severity level 5 (4 test cycles)
EN 60068-2-52 Kbseverity level 5 (4 test cycles)

Safety classification

Complies with the requirementsISO 13849-1: 2015 category 2, PL d
IEC 61508 SIL 2
IEC 62061 SIL 2
Mission time TM[h] [h]≤ 87600
Mission time TM (additional indication)industrial environments Temperature range -25...70 °C ≤ 175200
PFH[1/h] [1/h]< 5E-08

Mechanical data

Weight[g] [g]106.8
Housingthreaded type
Mountingnon-flush mountable
Dimensions[mm] [mm]M18 x 1 / L = 60
Thread designationM18 x 1
Materialsthreaded sleeve: brass white bronze coated; sensing face: LCP; LED window: PEI; lock nuts: brass white bronze coated
Tightening torque[Nm] [Nm]< 25

Displays / operating elements

DisplayDisplay switching status
4 LED, yellow
Display switching status4 LED, yellow

Accessories

Items suppliedlock nuts: 2

Remarks

Remarksmaterial for secure mounting not supplied; fixing must be done by the user
meets the environmental and EMC requirements for operation in agricultural and forestry machinery, earthworks and construction machines as well as in industrial trucks
Unless stated otherwise, all data refer to the reference target plate to IEC 60947-5-2 over the whole temperature range.
(FE360 = ST37-2K) 24x24x1 mm
Pack quantity1 pcs.

Electrical connection - plug

Connector1 x M12; coding: A; Contacts: gold-plated