Fast delivery within 72 Hours

IFM CR1141

CR1141

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Powerful, robust HMI with modern 64-bit architecture
RGB backlit function keys with tactile feedback.
High-performance USB interface as service interface
High-performance CAN interface for various communication tasks
Freely programmable to IEC 61131-3 with CODESYS 3.5

Specification

Product characteristics

Communication interfaceCAN; USB
Operating elements6
freely programmable backlit function keys
1
navigation key with central confirmation button
6freely programmable backlit function keys
1navigation key with central confirmation button
Display typecolour display

Application

Applicationfor mobile applications; For use in industrial environments; for use in wet environments

Electrical data

Operating voltage[V] [V]8...32 DC; (to SELV/PELV)
Nominal voltage DC[V] [V]12 / 24
Current consumption[mA] [mA]< 333; (24 V DC)
Power consumption[W] [W]8

Inputs / outputs

Number of inputs and outputsNumber of digital inputs: 1

Inputs

Number of digital inputs1; (non-configurable service input)

Software / programming

Parameter setting optionsCODESYS 3.5; Qt
PLC function to IEC 61131-3yes
Operating systemEmbedded Linux

Interfaces

Communication interfaceCAN; USB
Number of CAN interfaces1
Number of USB interfaces1
Transmission rate< 480 MBit/s
ProtocolCANopen; SAE J1939; free protocol
ProfileCiA DS 301 Version 4.2; CiA DS 401 Version 1.4
InterfaceCAN Interface 2.0 A/B ISO 11898
Factory settingsTransmission rate: 250 kBit/s
Version2.0

Operating conditions

Ambient temperature[°C] [°C]-30...65
Note on ambient temperature2000 m: -30...65 °C
3000 m: -30...61 °C
4000 m: -30...60 °C
5000 m: -30...58 °C
The mainboard temperature must not exceed 80 °C.
for further information please see the operating instructions
Storage temperature[°C] [°C]-30...85
Max. relative air humidity[%] [%]90; (non condensing)
Max. height above sea level[m] [m]5000
ProtectionIP 65; IP 67
Pollution degree2; (before installation and when the device is replaced)
Chemical mediaISO 16750-5
AA, BA, BD, CC, DB, DC, DD, ED
only one chemical permitted at a time
ISO 16750-5AA, BA, BD, CC, DB, DC, DD, ED

Tests / approvals

EMCUN/ECE-R10 noise emission and noise immunity:
100 V/m
DIN EN 61000-6-2
DIN EN 61000-6-4
DIN EN 13766-1
ISO 10605 ESD
immunity ISO 11452-1
ISO 7637-2 pulse 1
severity level 4 / function state C (24 V)
ISO 7637-2 pulse 2a
severity level 4 / function state A (24 V)
ISO 7637-2 pulse 2b
severity level 4 / function state C (24 V)
ISO 7637-2 pulse 3a
severity level 4 / function state A (24 V)
ISO 7637-2 pulse 3b
severity level 4 / function state A (24 V)
ISO 16750-2 pulse 4
severity level 4 / function state A (12 V)
ISO 16750-2 pulse 4
severity level 4 / function state A (24 V)
ISO 16750-2 pulse 5
severity level 3 / function state C (24 V)
ISO 16750-2 pulse 4
severity level 4 / function state A (12 V)
UN/ECE-R10 noise emission and noise immunity:100 V/m
ISO 7637-2 pulse 1severity level 4 / function state C (24 V)
ISO 7637-2 pulse 2aseverity level 4 / function state A (24 V)
ISO 7637-2 pulse 2bseverity level 4 / function state C (24 V)
ISO 7637-2 pulse 3aseverity level 4 / function state A (24 V)
ISO 7637-2 pulse 3bseverity level 4 / function state A (24 V)
ISO 16750-2 pulse 4severity level 4 / function state A (12 V)
ISO 16750-2 pulse 5severity level 3 / function state C (24 V)
Continuous shock resistanceISO 16750-3
30 g 6 ms / 24000 shocks
ISO 16750-330 g 6 ms / 24000 shocks
Fast temperature changeEN 60068-2-30 damp heat: cyclical
55 °C upper temperature limit / 6 cycles
EN 60068-2-78 damp heat: constant
40 °C 93 % rH / test period 21 days
EN 60068-2-30 damp heat: cyclical55 °C upper temperature limit / 6 cycles
EN 60068-2-78 damp heat: constant40 °C 93 % rH / test period 21 days
Vibration resistanceISO 16750-3 Test VII
random, mounting place car body
EN 60068-2-6 sine
10...500 Hz / 0.72 mm / 10 g 10 cycles/axis, sine
ISO 16750-3 Test VIIrandom, mounting place car body
EN 60068-2-6 sine10...500 Hz / 0.72 mm / 10 g 10 cycles/axis, sine
Salt spray testEN 60068-2-52 Salt spray
severity level 3 / motor vehicle
EN 60068-2-52 Salt sprayseverity level 3 / motor vehicle
MTTF[years] [years]112
Railway applicationsDIN EN 50155 Pkt 12.2
EN 50121-3-2
EN 55016

Mechanical data

Weight[g] [g]493.05
Type of mountingpanel / surface; installation in panels or panel cutouts; (panel cutout: 114 x 99 mm)
Dimensions[mm] [mm]125.1 x 110 x 41.3
Materialshousing: diecast aluminium powder-coated; Display: glass anti-reflective and hardened; rear of the housing: plastics; diaphragm: Gore-Tex
Information on service lifepushbuttons:
750000 Betätigungen
navigation key with pushbutton:
750000 Betätigungen
Display LED lifetime:
> 50000 h
pushbuttons:750000 Betätigungen
navigation key with pushbutton:750000 Betätigungen
Display LED lifetime:> 50000 h

Displays / operating elements

Displaystatus LED
1 LED, multi-colour freely programmable
status LED1 LED, multi-colour freely programmable
Operating elements6
freely programmable backlit function keys
1
navigation key with central confirmation button
6freely programmable backlit function keys
1navigation key with central confirmation button
Display resolution800 x 480
Display typecolour display
Display size4.3"
Aspect ratio16:10
Display background illuminationLED
Colour depth24 Bit
Brightness[cd/m²] [cd/m²]1000; (adjustable: 0...100 %; In steps of: 1 %)
Contrast ratio800:1

Hardware

ProcessorARM Dual Core 64 Bit 1,4 GHz
RAM1 GByte RAM
Mass storage4 GByte Flash
Non-volatile memory8 kByte

Data memories

Real-time clockyes; UTC, battery buffered

Remarks

Pack quantity1 pcs.

Electrical connection - CAN

Connector1 x M12; coding: A

Electrical connection - USB

Connector1 x M12; coding: B

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “IFM CR1141”

Your email address will not be published. Required fields are marked *