Fast delivery within 72 Hours
IFM CP100S
CP100S
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Programmable via CODESYS V3.5
CODESYS 3.5 safety libraries for mobile controllers from ifm
Specification
Application
| Application | for functionally safe applications with the ecomatBasic and the ecomatController |
|---|---|
| Function | software package for programming in CODESYS 3.5 SP18 |
| Software | CP100S |
| Hardware | CR403S, CR413S CR710S, CR711S CR720S, CR721S |
Inputs / outputs
| Input function | safety inputs 64 Connection IN00xx, IN01xx, IN02xx, IN03xx, IN04xx, IN05xx, IN06xx, IN07xx, IN08xx, IN09xx, IN10xx, IN11xx, IN12xx, IN13xx, IN14xx, IN15xx, IN16xx, IN17xx, IN18xx |
|---|---|
| Output function | safety outputs 68 Connection OUT00xx, OUT01xx, OUT02xx, OUT03xx, OUT04xx, OUT05xx |
Interfaces
| Protocol | CANopen Safety; SAE J1939-76 |
|---|
Tests / approvals
| EMC | DIN EN 61326-3-1 |
|---|
Safety classification
| Complies with the requirements | IEC 61508 SIL 2 ISO 26262 ASIL C |
|---|---|
| Mission time TM | 20 years |
| PFH [1/h] | external one-channel input 4.0E-09 external two-channel input 5.0E-10 logic 1,0E-07 external one-channel output 2.0E-08 external two-channel output 1.0E-09 |
| Total Life Time | 20 Jahre |
| TTrip | 10 h |
| Typical use case | PMFH: 48 Fit this classification applies to the following assumption: TLifetime (Total Operating Hours ) = 40000 h (operating and non-operating phase of the device considered) (this is equivalent to operation for 20 years, 8 h a day on 250 days of the year or 10 h a day on 200 days) |
| Worst case | PMFH: 73 Fit this classification applies to the following assumption: "always on" (non-operating phase of the device not considered) |
Remarks
| Remarks | can be used in applications up to SIL 2 in accordance with IEC 62061 can be used in applications up to PL d in accordance with ISO 13849-1 can be used in applications up to AgPL d in accordance with ISO 25119 can be used in applications in accordance with DIN EN ISO 13766-2 |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM CP100S” Cancel reply

Reviews
Clear filtersThere are no reviews yet.