Fast delivery within 72 Hours
IFM AL4342
AL4342
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Fieldbus module with digital inputs and outputs
Direct connection of actuators and sensors to the fieldbus for a clear wiring structure
Connection of large actuators possible
High-frequency counter function with the option of direct switching of the outputs
Daisy-chain power supply with standardised L-coded M12 connection technology
Specification
Application
| Application | I/O modules for field applications |
|---|---|
| Daisy-chain function | power supply; fieldbus interface |
Electrical data
| Operating voltage[V] [V] | 20...30 DC; (US ; to PELV) |
|---|---|
| Current consumption[mA] [mA] | 300...3900 |
| Protection class | III |
| Additional voltage supply[V] [V] | 20...30 DC; (UA) |
| Max. current load total[A] [A] | 3.6 |
| Current rating per port[A] [A] | 3.6 |
Inputs / outputs
| Number of inputs and outputs | Number of digital inputs: 8; Number of digital outputs: 8 |
|---|
Inputs
| Number of digital inputs | 8; (type 2 according to IEC 61131-2) |
|---|---|
| Switching level high[V] [V] | 11...30 |
| Switching level low[V] [V] | 0...5 |
| Digital inputs protected against short circuits | yes |
Outputs
| Number of digital outputs | 8 |
|---|---|
| Short-circuit proof | yes |
| Max. current load per output[mA] [mA] | 3600 |
Software / programming
| Parameter setting options | counter function |
|---|---|
| Functions and parameters | function CTU (Up Counter), CTD (Down Counter), CTUD (Up-Down Counter), CTDIR (Direction Counter) switching function (SSC) single point, two point, window, latch number 4 (1 counter for each input port) count frequency 4500 Hz main counter 32 Bit (0…4.294.967.295) batch counter 16 Bit (0…65.535) |
| function | CTU (Up Counter), CTD (Down Counter), CTUD (Up-Down Counter), CTDIR (Direction Counter) |
| switching function (SSC) | single point, two point, window, latch |
| number | 4 (1 counter for each input port) |
| count frequency | 4500 Hz |
| main counter | 32 Bit (0…4.294.967.295) |
| batch counter | 16 Bit (0…65.535) |
Interfaces
| Communication interface | Ethernet |
|---|---|
| Protocol | Modbus TCP |
| Transmission standard | 10Base-T; 100Base-TX |
| Transmission rate | 10 MBit/s; 100 MBit/s |
| Factory settings | IP address: 192.168.1.250 subnet mask: 255.255.255.0 gateway IP address: 0.0.0.0 MAC address: see type label |
Operating conditions
| Ambient temperature[°C] [°C] | -25...60 |
|---|---|
| Storage temperature[°C] [°C] | -25...85 |
| Max. relative air humidity[%] [%] | 90 |
| Protection | IP 65; IP 66; IP 67 |
| Protection rating (NEMA 250) | 6P |
| Pollution degree | 2 |
| Chemical media | ISO 16750-5 AA, BA, BD, HLP, CC, DB, DC, DD, CA NEMA 250 5.13.1 AA |
| ISO 16750-5 | AA, BA, BD, HLP, CC, DB, DC, DD, CA |
| NEMA 250 5.13.1 | AA |
Tests / approvals
| EMC | EN 61000-6-2 EN 61000-6-4 |
|---|---|
| Shock resistance | DIN EN 60068-2-27 |
| Vibration resistance | DIN EN 60068-2-64 2009-04 DIN EN 60068-2-6 2008-10 |
Mechanical data
| Weight[g] [g] | 423.3 |
|---|---|
| Housing | rectangular |
| Type of mounting | backplane mounting |
| Dimensions[mm] [mm] | 208 x 59.3 x 38.4 |
| Materials | housing: PA orange; socket: brass nickel-plated |
| Sealing material | FKM |
Remarks
| Remarks | For further information please see the operating instructions. Using the device within a system with requirements for functional safety is possible by deactivating the actuator voltage UA without interaction. For further information on functional safety, please refer to the operating instructions supplement under “Downloads”. |
|---|---|
| Pack quantity | 1 pcs. |
Electrical connection - Ethernet
| Connector | M12; coding: D; Sealing: FKM |
|---|
Electrical connection - IO-Link
| Connector | M12; coding: A; Sealing: FKM |
|---|
Electrical connection - power supply IN
| Connector | M12; coding: L |
|---|
Electrical connection - power supply OUT
| Connector | M12; coding: L; Sealing: FKM |
|---|
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “IFM AL4342” Cancel reply

Reviews
Clear filtersThere are no reviews yet.