Fast delivery within 72 Hours

Sick TR4-SAM03PB

Safety switches | TR4 Direct | TR4-SAM03PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Safety switches | TR4 Direct | TR4-SAM03PB | System part: Sensor with actuator | Coding: Universally coded | Assured switch on distance Sao: 15 mm | Connection type Detail: Cable | Length of cable: 3 m | Safe series connection: In control cabinet (with diagnostics) | Status display: yes | Boundary area indication: no

Specification

Features

System partSensor with actuator
Sensor principleRFID
Number of safe outputs2
Assured switch on distance Sao15Â mm
Assured switch off distance Sar25Â mm
Active sensor surfaces2
Actuation directions5
CodingUniversally coded

Safety-related parameters

Safety integrity levelSIL 3Â (IECÂ 61508)
CategoryCategory 4Â (ENÂ ISOÂ 13849)
Performance levelPL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour)6.03Â * 10-10
TM (mission time)20Â years (ENÂ ISOÂ 13849)
TypeType 4Â (ENÂ ISOÂ 14119)
Actuator coding levelLow coding level (ENÂ ISOÂ 14119)
Classification in compliance with IEC/ENÂ 60947-5-3PDF-M
Safe state in the event of a faultAt least one safety-related semiconductor output (OSSD) is in the OFF state.

Functions

Safe series connectionIn control cabinet (with diagnostics)

Interfaces

Connection typeCable
Length of cable3Â m
Long connecting cable≤ 200 m
Cable diameter6.5Â mm
Conductor cross section0.25 mm²
Bend radius (with fixed installation)> 7Â x cable diameter
Bend radius (with moving cable)> 14Â x cable diameter
Cable materialPVC
Conductor materialCopper
Display elementsLEDs
Status display✔

Electronics

Protection classIII (ENÂ 50178)
Classification according to cULusClass 2
Supply voltage Vs24Â VÂ DC (20.4Â VÂ DCÂ ... 26.4Â VÂ DC)
Power consumption≤ 50 mA
Type of outputSelf-monitoring semiconductor outputs (OSSDs)
Output current≤ 200 mA
Response time45 ms 1)
Release time360 ms 2)
Risk time≤ 100 ms 3)
Switch-on time2 s 4)
Electrical life10 x 106 switching cycles

Mechanics

DesignCylindrical
Housing diameter (sensor/actuator)M18Â / M18
Weight218Â g
Housing materialValox® DR48

Ambient data

Enclosure ratingIP67 (IECÂ 60529)IP69K (ISOÂ 20653)
Ambient operating temperature–25 °C ... +70 °C
Vibration resistance10 Hz ... 55 Hz, 3.5 mm (IEC 60068-2-6)
Shock resistance30Â g, 11Â ms (ENÂ 60068-2-27)

Classifications

ECLASS 5.027272403
ECLASS 5.1.427272403
ECLASS 6.027272403
ECLASS 6.227272403
ECLASS 7.027272403
ECLASS 8.027272403
ECLASS 8.127272403
ECLASS 9.027272403
ECLASS 10.027272403
ECLASS 11.027272403
ECLASS 12.027274601
ETIM 5.0EC001829
ETIM 6.0EC001829
ETIM 7.0EC001829
ETIM 8.0EC001829
UNSPSC 16.090139122205

Certificates

EU declaration of conformity✔
UK declaration of conformity✔
ACMA declaration of conformity✔
China RoHS✔
cULus certificate✔
EC-Type-Examination approval✔