Fast delivery within 72 Hours

Sick RLY3-OSSD100

sens:Control – safe control solutions | ReLy | RLY3-OSSD100 | Applications: Output expansion module for OSSDs | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector wi…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

sens:Control – safe control solutions | ReLy | RLY3-OSSD100 | Applications: Output expansion module for OSSDs | Compatible sensor types: Safety sensors with OSSDs | Connection type: Front connector with spring terminals | Restart interlock: no | External device monitoring (EDM): Via path | Outputs: 2 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe) | Housing width: 18 mm

Specification

Features

ApplicationsOutput expansion module for OSSDs
Compatible sensor typesSafety sensors with OSSDs

Safety-related parameters

Safety integrity levelSIL 3Â (IECÂ 61508)
CategoryCategory 4Â (ISOÂ 13849-1)
Performance levelPL e (ISO 13849-1)
PFHD (mean probability of a dangerous failure per hour)1.0Â x 10-9
TM (mission time)20Â years (ISOÂ 13849-1)
Stop category0Â (IECÂ 60204-1)

Functions

Path for external device monitoring (EDM)✔

Interfaces

Connection typeFront connector with spring terminals
Inputs2Â safety inputs
Outputs2Â enabling current paths (safe)1Â feedback current path (for use as external device monitoring, not safe)
Display elementsLEDs

Electronics

Voltage supplyPassive (no active voltage supply)
Power consumption (input circuits)≤ 1.5 W (DC)
Number2
Input voltage HIGH24Â VÂ DC (15Â VÂ ... 30Â V)
Input voltage LOW0 V DC (–3 V ... 5 V)
Input current≤ 50 mA
Test pulse width≤ 1 ms
Test pulse rate≤ 10 Hz
Response time (opening of enabling current paths)12Â ms
Number2
Type of outputN/O contacts, positively guided
Contact materialSilver alloy, gold flashed
Switching voltage10Â VÂ ACÂ ... 230Â VÂ AC
Switching current10Â mAÂ ... 6Â A
Total current12Â A
Mechanical life1 x 107 switching cycles
Overvoltage categoryIII (ENÂ 60664-1)
Rated impulse withstand voltage Uimp6Â kV (ENÂ 60664-1)
Number1
Type of outputN/C contact, positively guided
Contact materialSilver alloy, gold flashed
Switching voltage15Â VÂ ACÂ ... 30Â VÂ AC
Switching current3Â mAÂ ... 100Â mA
Mechanical life1 x 107 switching cycles

Mechanics

Dimensions (W x H x D)18 mm x 124.6 mm x 85.5 mm
Weight130Â g

Ambient data

Enclosure ratingIP20 (IECÂ 60529)
Ambient operating temperature–25 °C ... +55 °C
Storage temperature–25 °C ... +70 °C
Air humidity≤ 95 %, Non-condensing
Interference emissionAccording to IECÂ 61000-6-4
Interference resistanceAccording to IECÂ 61326-3-1According to IECÂ 61000-6-2According to IECÂ 60947-5-1

Certificates

EU declaration of conformity✔
UK declaration of conformity✔
ACMA declaration of conformity✔
China RoHS✔
CCC certificate✔
UK-Type-Examination approval✔
cULus certificate✔
EAC certificate / DoC✔
cTUVus certificate✔
S Mark certificate✔
EC-Type-Examination approval✔
EC-Type-Examination approval (Machinery Directive)✔
EC-Type-Examination approval (Machinery Regulation)✔
Third party certificate✔

Classifications

ECLASS 5.027371990
ECLASS 5.1.427371990
ECLASS 6.027371819
ECLASS 6.227371819
ECLASS 7.027371819
ECLASS 8.027371819
ECLASS 8.127371819
ECLASS 9.027371819
ECLASS 10.027371819
ECLASS 11.027371819
ECLASS 12.027371819
ETIM 5.0EC001449
ETIM 6.0EC001449
ETIM 7.0EC001449
ETIM 8.0EC001449
UNSPSC 16.090141113704

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Sick RLY3-OSSD100”

Your email address will not be published. Required fields are marked *