Fast delivery within 72 Hours
Sick PICS120-AX1100
LiDAR sensors | picoScan100 | PICS120-AX1100 | Working range: 0.05 m … 30 m | Angular resolution: 0.1° | Scanning frequency: 20 Hz | Integrated application: Output of measurement data | Digital add-…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
LiDAR sensors | picoScan100 | PICS120-AX1100 | Working range: 0.05 m … 30 m | Angular resolution: 0.1° | Scanning frequency: 20 Hz | Integrated application: Output of measurement data | Digital add-ons: LMDscandata (data format), Reflector detection | Connection type: 1 “Ethernet” connection, 4-pin M12 female connector (0.25 m), D-coded, 1 “POWER” connection, 5-pin M12 male connector (0.35 m), A-coded | Variant: Standard (not pre-configured)
Specification
Features
| Application | Indoor |
|---|---|
| Variant | Standard (not pre-configured) |
| Measurement principle | HDDM+ |
| Light source | Infrared (905Â nm) |
| Laser class | 1Â (IECÂ 60825-1:2014, ENÂ 60825-1:2014+A11:2021) |
| Horizontal | 276° |
| Scanning frequency | 20Â Hz |
| Horizontal | 0.1° |
| Scan field flatness | Typ. ± 1° |
| Working range | 0.05 m ... 30 m 1) |
| Blind zone | 0 m ... 0.05 m |
| At 90% remission and 10Â klx | 30Â m |
| At 10% remission and 10Â klx | 18Â m |
| Spot size | Divergence, typ.: 4.8Â mradOn the optics cover: 8Â mm |
| Amount of evaluated echoes | 1 |
Mechanics/electronics
| Connection type | 1Â x âEthernetâ connection, 4-pin M12 female connector (0.25Â m), D-coded1Â x âPOWERâ connection, 5-pin M12 male connector (0.35Â m), A-coded |
|---|---|
| Supply voltage | 9Â VÂ DCÂ ... 30Â VÂ DC |
| Power consumption | Typ. 4.5 W, Max. 10.5 W with loaded digital outputs |
| Output current | â¤Â 200 mA |
| Housing material | Aluminum |
| Housing color | Anthracite gray (RALÂ 7016) |
| Optical hood | Polycarbonate, scratch-resistant coating |
| Enclosure rating | IP65 (IECÂ 60529:1989+AMD1:1999+AMD2:2013) |
| Protection class | III (IECÂ 61140:2016-11) |
| Electrical safety | IECÂ 61010-1:2010-06+AMD1:2016 |
| Weight | 220Â g, without connecting cable250Â g, with connecting cable |
| Dimensions (L x W x H) | 60 mm x 60 mm x 82 mm (without connecting cable) |
| Ventilation element | Yes |
| MTBF | >Â 100Â years |
Safety-related parameters
| MTTFD | > 100 years, at 25 °C ambient temperature (EN ISO 13849-1:2015) |
|---|
Functions
| Digital add-ons | LMDscandata (data format)Reflector detection |
|---|
Performance
| Data output per scan segment | Segment size 30° |
|---|---|
| Scan/frame rate | 55,201Â measurement point/s |
| Latency of the measurement data output | Segment size 30°: â¤Â 10 ms (3 Ï) |
| Detectable object shape | Almost any |
| Systematic error | Typ. ± 20 mm 1)Max. ± 30 mm |
| Statistical error | â¤Â 5 mm (0.05 m ... 5 m) 2) |
| Integrated application | Output of measurement data |
Interfaces
| Ethernet | â , UDP/IPÂ Singlecast (Compact, MSGPACK), UDP/IPÂ Multicast (Compact, MSGPACK), TCP/IPÂ (LMDscandata) |
|---|---|
| Function | Measurement data output (distance, RSSI, time stamp, reflector mark), DHCP, NTP |
| Data transmission rate | 10 Mbit/s ... 100 Mbit/s, half/full-duplex |
| Digital inputs/outputs | 1Â (Device Not Ready) |
| Optical indicators | 2Â LEDs |
| Configuration software | SOPASair (web browser)SOPASÂ ET (software)REST API |
| Driver | ROS1, ROS2, C++, Python |
Ambient data
| Object remission | 1.8Â %Â ... >Â 1,000Â % (Reflector) |
|---|---|
| Emitted radiation | Industrial environment (IECÂ 61000-6-4:2018 / ENÂ IECÂ 61000-6-4:2019 / IECÂ 61000-6-4:2006+A1:2010 / ENÂ 61000-6-4:2007+A1:2011) |
| Emitted radiation | Business and commercial areas as well as small enterprises (IECÂ 61000-6-8:2020 / ENÂ IECÂ 61000-6-8:2020) |
| Electromagnetic immunity | Industrial environment (IECÂ 61000-6-2:2016 / ENÂ IECÂ 61000-6-2:2019 / IECÂ 61000-6-2:2005 / ENÂ 61000-6-2:2005 / ENÂ 61000-6-2:2005/AC:2005) |
| Emitted radiation | Residential area (ENÂ 61000-6-3:2007+AMD:A1:2011) |
| Sine resonance scan | 10 Hz ... 1,000 Hz, 1 g 1) |
| Sine test | 10 Hz ... 500 Hz, 10 g, 10 frequency cycles 1) |
| Noise test | 10 Hz ... 500 Hz, 13.5 g RMS, 5 h 2) |
| Shock resistance | 100 g, 6 ms, ± 3 single shocks/axis 3)40 g, 6 ms, ± 4,000 continuous shocks/axis 3)50 g, 3 ms, ± 5,000 continuous shocks/axis 3)No measurement data availability |
| Ambient operating temperature | â10 °C ... +50 °C |
| Storage temperature | â30 °C ... +70 °C |
| Temperature change | â10 °C ... +50 °C, 10 cycles 4) |
| Cyclical | + 25 °C ... + 55 °C, 95 % RH, non-condensing (operation/storage/transport) (EN 60068-2-30) |
| Operation | <Â 80Â %, Non-condensing (ENÂ 60068-2-30:2005) |
| Storage | â¤Â 90 %, Non-condensing (EN 60068-2-30:2005) |
| Ambient light immunity | 80Â klx, indirect |
| Altitude (above sea level) | <Â 5,000Â m |
General notes
| Note on use | The sensor does not constitute a safety component as defined by relevant legislation on machine safety. |
|---|
Certificates
| EU declaration of conformity | â |
|---|---|
| UK declaration of conformity | â |
| ACMA declaration of conformity | â |
| China RoHS | â |
| cTUVus certificate | â |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | â |
Classifications
| ECLASS 5.0 | 27270990 |
|---|---|
| ECLASS 5.1.4 | 27270990 |
| ECLASS 6.0 | 27270913 |
| ECLASS 6.2 | 27270913 |
| ECLASS 7.0 | 27270913 |
| ECLASS 8.0 | 27270913 |
| ECLASS 8.1 | 27270913 |
| ECLASS 9.0 | 27270913 |
| ECLASS 10.0 | 27270913 |
| ECLASS 11.0 | 27270913 |
| ECLASS 12.0 | 27270913 |
| ETIM 5.0 | EC002550 |
| ETIM 6.0 | EC002550 |
| ETIM 7.0 | EC002550 |
| ETIM 8.0 | EC002550 |
| UNSPSC 16.0901 | 41111615 |

Reviews