Magnetic sensors | MLS | MLSE-0200C2NUA | Detection range typ.: 200 mm | Connection type: Cable, 4-wire, 3 m | Terminal resistor: No internal terminator | Enclosure rating: IP65, IP67, IP68 | Teach-in: yes | Electrical wiring: DC 4-wire | Communication interface: Modbus
Specification
Features
| Detection range typ. | 200Â mm |
|---|---|
| Operating height | 10 mm ... 70 mm |
| Electrical wiring | DC 4-wire |
| Enclosure rating | IP65, IP67, IP68Â 1) |
Mechanics/electronics
| Supply voltage | 9Â VÂ DCÂ ... 30Â VÂ DC |
|---|---|
| Terminal resistor | No internal terminator |
| Protection class | III |
| Power consumption | 600Â mW |
| Resolution, typ. | 1Â mm |
| Repeat accuracy, typ. | 1Â mm |
| Update rate | 100Â Hz |
| Teach-in | ✔ |
| Reverse polarity protection | Yes |
| Short-circuit protection | Yes |
| Ambient operating temperature | –20 °C ... +70 °C |
| Shock and vibration resistance | 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm |
| EMC | ENÂ 61000-6-2, ENÂ 61000-6-4 |
| Connection type | Cable, 4-wire, 3 m 1) |
| Conductor cross section | 0.08 mm² |
| Cable diameter | Ø 2.6 mm |
| Bending radius | With fixed installation >Â 5Â x cable diameter |
| Cable outlet | Axial |
| Housing | Metal, Aluminum, plastic |
| Cable | PUR |
| UL File No. | NRKH.E181493 & NRKH7.E181493 |
Safety-related parameters
| MTTFD | 143Â years |
|---|---|
| DCavg | 0Â % |
| TM (mission time) | 20Â years |
Communication interface
| Communication interface | Modbus |
|---|---|
| Communication Interface detail | RTU RS-485 |
Diagnosis
| Number of axis | 3 |
|---|---|
| Roll Euler angle measuring range | ± 180° |
| Pitch Euler angle measuring range | ± 90° |
| Yaw Euler angle measuring range | ± 180° |
| Resolution | 0.02° |
| Roll repeatability | ± 1° |
| Pitch repeatability | ± 1° |
| Yaw repeatability | ± 1° 1) |
| Maximum rotation rate | 2,000 °/s |
| Quaternion w measuring range | 0Â ... +Â 1 |
| Quaternion x measuring range | –1 ... 1 |
| Quaternion y measuring range | –1 ... 1 |
| Quaternion z measuring range | –1 ... 1 |
| Update rate | 100Â Hz |
| Limit frequency | 100Â Hz |
| Initialization time | 640Â ms |
| Sampling rate | 200 Hz 2) |
| Acceleration measuring range | ± 16 g 2) |
| Rotation rate measuring range | ± 2,000 °/s 2) |
Certificates
| EU declaration of conformity | ✔ |
|---|---|
| UK declaration of conformity | ✔ |
| ACMA declaration of conformity | ✔ |
| Moroccan declaration of conformity | ✔ |
| China RoHS | ✔ |
| cULus certificate | ✔ |
Classifications
| ECLASS 5.0 | 27270104 |
|---|---|
| ECLASS 5.1.4 | 27270104 |
| ECLASS 6.0 | 27270104 |
| ECLASS 6.2 | 27270104 |
| ECLASS 7.0 | 27270104 |
| ECLASS 8.0 | 27270104 |
| ECLASS 8.1 | 27270104 |
| ECLASS 9.0 | 27270104 |
| ECLASS 10.0 | 27270104 |
| ECLASS 11.0 | 27270104 |
| ECLASS 12.0 | 27274301 |
| ETIM 5.0 | EC002544 |
| ETIM 6.0 | EC002544 |
| ETIM 7.0 | EC002544 |
| ETIM 8.0 | EC002544 |
| UNSPSC 16.0901 | 39122230 |