Fast delivery within 72 Hours
Sick M4P-EA04300C00
Safety light-beam sensors | deTem | M4P-EA04300C00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Receiver | Application: Normal industrial environment | Safety level…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Safety light-beam sensors | deTem | M4P-EA04300C00 | Product version: deTem4 | Functional principle: Sender/receiver | System part: Receiver | Application: Normal industrial environment | Safety level: PL e, SIL 3, Type 4 | Functions: Protective operation, beam coding, restart interlock, external device monitoring (EDM), Differentiation between person and material | Scanning range: 90 m | Number of beams: 4 | Beam separation: 300 mm | Connection type: Depending on system plug (M12 male connector, 5-pin or 8-pin) | Extension connection: Depending on system plug (without extension connection or with M12 female connector, 5-pin) | End cap with integrated LED: no | Integrated laser alignment aid: no | Enclosure rating: IP65, IP67 | Items supplied: Receiver, safety instruction, Mounting instructions, Operating instructions for download
Specification
Features
| Product version | deTem4 |
|---|---|
| Application | Normal industrial environment |
| Functional principle | Sender/receiver |
| System part | Receiver |
| Scanning range | 90Â m |
| Number of beams | 4 |
| Beam separation | 300Â mm |
| Response time | 20Â ms |
| Synchronization | Optical synchronization |
| Items supplied | ReceiverSafety instructionMounting instructionsOperating instructions for download |
Safety-related parameters
| Type | Type 4Â (IECÂ 61496) |
|---|---|
| Safety integrity level | SIL 3Â (IECÂ 61508, IECÂ 62061) |
| Category | Category 4Â (ISOÂ 13849) |
| Performance level | PL e (ISO 13849) |
| PFHD (mean probability of a dangerous failure per hour) | 6.6 × 10-9 |
| TM (mission time) | 20Â years (ISOÂ 13849) |
| Safe state in the event of a fault | At least one OSSD is in the OFF state. |
Functions
| Note | The deTem4 safety light-beam sensor can be used with different function packages. The function packages are determined by the equipment used. |
|---|---|
| Function package SP1 | Protective operationBeam codingRestart interlockExternal device monitoring (EDM)Application diagnostic output (ADO)IO-LinkEquipment: Sender and receiver with SP1 system plug |
| Function package SP2 | Function package SP1 includedManual adjustment of the protective field widthMuting (2-signal muting)Partial mutingEquipment: Sender with SP1 system plug and receiver with SP2 system plug |
| Function package DMM4 | Function package SP2 includedTransmitting power adjustmentMuting (4-signal muting)Operating mode selectionInputs for safety sensors (SDI)Equipment: Sender and receiver with SP1 system plug and DMM4 extension module |
Interfaces
| System connection | Depending on system plug (M12 male connector, 5-pin or 8-pin) |
|---|---|
| Extension connection | Depending on system plug (without extension connection or with M12 female connector, 5-pin) |
| Configuration method | DIPÂ switch on system plugPC software via DMM4 (Safety Designer) |
| Display elements | Status LEDs |
| Alignment aid | Alignment quality via diagnostic LEDs |
| Application diagnostic output (ADO) | ✔ |
| IO-Link | ✔ |
| Near Field Communication (NFC) | ✔ |
Electronics
| Protection class | III (IECÂ 61140)Â 1) |
|---|---|
| Supply voltage VS | 24Â VÂ DC (19.2Â VÂ DCÂ ... 28.8Â VÂ DC)Â 2) |
| Residual ripple | ≤ 10 % 3) |
| Output signal switching devices (OSSDs) | 2 PNP semiconductors, short-circuit protected, cross-circuit monitored 4) |
| ON state, switching voltage HIGH | 24 V DC (VS – 2.25 V DC ... VS) |
| OFF state, switching voltage LOW | ≤ 2 V DC |
| Current-carrying capacity per OSSD | ≤ 500 mA |
| Application diagnostic output (ADO) | PNP semiconductor, short-circuit protected 4) |
| Output voltage HIGH (active) | ≥ Vs – 3 V |
| Output voltage LOW (deactivated) | High resistance |
| Current loading | ≤ 100 mA |
Mechanics
| Dimensions | See dimensional drawing |
|---|---|
| Housing cross-section | 30.7 mm x 34 mm |
| Housing | Aluminum extruded profile |
| Front screen | Polycarbonate, scratch-resistant coating |
Ambient data
| Enclosure rating | IP65 (IECÂ 60529)IP67 (IECÂ 60529) |
|---|---|
| Ambient operating temperature | –30 °C ... +55 °C |
| Storage temperature | –30 °C ... +70 °C |
| Air humidity | 15Â %Â ... 95Â %, Non-condensing |
| Vibration resistance | 5 … 150 Hz, 3,5 mm / 1 g (EN 60068-2-6) |
| Shock resistance | 15Â g / 6Â ms (ENÂ 60068-2-27) |
| Class | 3M4 (IECÂ TR 60721-4-3) |
| EMC | According to IECÂ 61496-1, IECÂ 61000-6-2, IECÂ 61000-6-4 |
Classifications
| ECLASS 5.0 | 27272703 |
|---|---|
| ECLASS 5.1.4 | 27272703 |
| ECLASS 6.0 | 27272703 |
| ECLASS 6.2 | 27272703 |
| ECLASS 7.0 | 27272703 |
| ECLASS 8.0 | 27272703 |
| ECLASS 8.1 | 27272703 |
| ECLASS 9.0 | 27272703 |
| ECLASS 10.0 | 27272703 |
| ECLASS 11.0 | 27272703 |
| ECLASS 12.0 | 27272703 |
| ETIM 5.0 | EC001832 |
| ETIM 6.0 | EC001832 |
| ETIM 7.0 | EC001832 |
| ETIM 8.0 | EC001832 |
| UNSPSC 16.0901 | 46171620 |
Certificates
| EU declaration of conformity | ✔ |
|---|---|
| UK declaration of conformity | ✔ |
| ACMA declaration of conformity | ✔ |
| Moroccan declaration of conformity | ✔ |
| China RoHS | ✔ |
| ULus approval | ✔ |
| cUL approval | ✔ |
| EC-Type-Examination approval | ✔ |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | ✔ |

Reviews