Fast delivery within 72 Hours
Sick FXL1-SPLMAA00
Safety switches | flexLock | FXL1-SPLMAA00 | Locking principle: Power to lock | Switching behavior of the OSSDs: Actuator monitoring | Switching behavior of the application diagnostic output: Actuator…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Safety switches | flexLock | FXL1-SPLMAA00 | Locking principle: Power to lock | Switching behavior of the OSSDs: Actuator monitoring | Switching behavior of the application diagnostic output: Actuator monitoring | Coding: Universally coded | Auxiliary release: no | Escape release: no | Retaining force: 30 N
Specification
Features
| Sensor principle | RFID |
|---|---|
| Locking principle | Power to lock |
| Coding | Universally coded |
| Flexible actuator | 4,100Â N (ENÂ ISOÂ 14119) |
| Rigid actuator (frontal) | 3,630Â N (ENÂ ISOÂ 14119) |
| Rigid actuator (lateral) | 3,510Â N (ENÂ ISOÂ 14119) |
| Flexible actuator | 3,150Â N (ENÂ ISOÂ 14119) |
| Rigid actuator (frontal) | 2,790Â N (ENÂ ISOÂ 14119) |
| Rigid actuator (lateral) | 2,700Â N (ENÂ ISOÂ 14119) |
| Actuation force | 20Â N |
| Retaining force | 30Â N |
| Force against which unlocking is possible | ≤ 25 N |
| Actuation frequency | ≤ 1 Hz |
| Approach speed | ≤ 20 m/min |
Safety-related parameters
| Safety integrity level | SIL 3Â (IECÂ 61508) |
|---|---|
| Category | Category 4Â (ENÂ ISOÂ 13849)Â 1) |
| Performance level | PL e (EN ISO 13849) 1) |
| PFHD (mean probability of a dangerous failure per hour) | 9.55 x 10-9 2) |
| TM (mission time) | 20Â years (ENÂ ISOÂ 13849) |
| Type | Type 4Â (ENÂ ISOÂ 14119) |
| Actuator coding level | Low coding level (ENÂ ISOÂ 14119) |
| Safe state in the event of a fault | At least one safety-related semiconductor output (OSSD) is in the OFF state. |
Functions
| Switching behavior of the OSSDs | Actuator monitoring |
|---|---|
| Switching behavior of the application diagnostic output | Actuator monitoring |
| Safe series connection | In control cabinet (with diagnostics)With Flexi Loop (with diagnostics)With T-connector (without diagnostics) |
Interfaces
| Connection type | Plug connector, M12, 8-pin |
|---|---|
| Coupling nut material | Stainless steel |
| Display elements | LEDs |
| Diagnostics indicator | ✔ |
| Status display | ✔ |
Electronics
| Protection class | III (IECÂ 61140) |
|---|---|
| Contamination rating | 3Â (IECÂ 60947-1) |
| Classification according to cULus | Class 2 |
| Usage category | DC-13 (IECÂ 60947-5-3) |
| Rated insulation voltage Ui | 32Â V |
| Rated impulse withstand voltage Uimp | 1,500Â V |
| Supply voltage VS | 24Â VÂ DC (19.2Â VÂ DCÂ ... 28.8Â VÂ DC) |
| Locking device unlocked | 65Â mA |
| Locking device locked | 125Â mA |
| Peak current | 800Â mA, 200Â ms |
| Type of output | Self-monitoring semiconductor outputs (OSSDs) |
| Safety outputs | 2Â PNP semiconductors, short-circuit protected, cross-circuit monitored |
| Safety outputs | ≤ 100 mA |
| Application diagnostic outputs | ≤ 50 mA |
| Output voltage | UV - 2Â VÂ DCÂ ... UV |
| Response time | ≤ 150 ms 1) |
| Release time | ≤ 350 ms 1) |
| Risk time | 150 ms 1) |
| Switch-on time | 3Â s |
| Locking principle | Power to lock |
Mechanics
| Weight | 535Â g |
|---|---|
| Housing | VISTAL® |
| Ball bracket | Stainless steel |
| Latch plate of the actuator | Stainless steel |
| Plug connectors | Stainless steel |
| Mechanical life | 1 x 106 switching cycles |
Ambient data
| Enclosure rating | IP65, IP67, IP69K (IECÂ 60529, IECÂ 60529, IECÂ 20653) |
|---|---|
| Ambient operating temperature | –20 °C ... +55 °C |
| Storage temperature | –25 °C ... +70 °C |
| Relative humidity | 10 % ... 95 %, at 40 °C (IEC 60068) |
| Vibration resistance | 10 Hz ... 55 Hz, 1 mm (IEC 60068-2-6) |
| Shock resistance | 30Â g, 11Â ms (ENÂ 60068-2-27) |
| EMC | ENÂ IECÂ 61326-3-1ENÂ IECÂ 60947-5-2ENÂ IECÂ 60947-5-3ENÂ 300330 |
Certificates
| EU declaration of conformity | ✔ |
|---|---|
| ACMA declaration of conformity | ✔ |
| China RoHS | ✔ |
| ECOLAB certificate | ✔ |
| cULus certificate | ✔ |
| EC-Type-Examination approval | ✔ |
| Third party certificate | ✔ |
Classifications
| ECLASS 5.0 | 27272603 |
|---|---|
| ECLASS 5.1.4 | 27272603 |
| ECLASS 6.0 | 27272603 |
| ECLASS 6.2 | 27272603 |
| ECLASS 7.0 | 27272603 |
| ECLASS 8.0 | 27272603 |
| ECLASS 8.1 | 27272603 |
| ECLASS 9.0 | 27272603 |
| ECLASS 10.0 | 27272603 |
| ECLASS 11.0 | 27272603 |
| ECLASS 12.0 | 27272603 |
| ETIM 5.0 | EC002593 |
| ETIM 6.0 | EC002593 |
| ETIM 7.0 | EC002593 |
| ETIM 8.0 | EC002593 |
| UNSPSC 16.0901 | 39122205 |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0