Fast delivery within 72 Hours
Sick FLN-OSSD1000105
Safe series connection | Flexi Loop | FLN-OSSD1000105 | Flexi Loop component: Node for safety sensors (OSSD) | Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard i…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Safe series connection | Flexi Loop | FLN-OSSD1000105 | Flexi Loop component: Node for safety sensors (OSSD) | Use of Flexi Loop node: For safety sensor with dual-channel OSSD outputs, With standard input | Connection type safety device: Female connector M12, 5-pin
Specification
Safety-related parameters
| Safety integrity level | SIL 3Â (IECÂ 61508) |
|---|---|
| Category | Category 4Â (ENÂ ISOÂ 13849) |
| Performance level | PL e (EN ISO 13849) |
| PFHD (mean probability of a dangerous failure per hour) | 0.76 x 10-9 (EN ISO 13849) |
| TM (mission time) | 20Â years (ENÂ ISOÂ 13849) |
Functions
| Cross-circuit | Monitoring via OSSD device |
|---|---|
| Short-circuit | Monitoring via OSSD device |
| Discrepancy errors | Monitoring via Flexi Loop node |
| Sequence errors | Monitoring via Flexi Loop node |
Interfaces
| Safety device connection | For safety sensor with dual-channel OSSD outputs, With standard input |
|---|---|
| Flexi Loop input | To connect to a Flexi Loop predecessor node or to connect the Flexi Loop line to the Flexi Soft safety controller. |
| Flexi Loop output | To connect to a Flexi Loop successor node or to terminate the Flexi Loop line with the Flexi Loop terminator. |
| Safety device connection | Female connector M12, 5-pin |
| Flexi Loop input | Male connector M12, 5-pin |
| Flexi Loop output | Female connector M12, 5-pin |
| Number of non-safe inputs | 1 |
| Number of non-safe outputs | 0 |
| Power supply output for external devices | ✔ |
Electrical data - Operating data
| Protection class | III (ENÂ 61140) |
|---|---|
| Type of supply voltage | PELV or SELV |
| Supply voltage Vs | 24Â VÂ DC (16.8Â VÂ DCÂ ... 30Â VÂ DC) |
| Power consumption | 45Â mA |
Electrical data - OSSD inputs
| HIGH | 13Â VÂ DCÂ ... 30Â VÂ DC |
|---|---|
| LOW | –5 V DC ... 5 V DC |
| HIGH | 3.5Â mAÂ ... 6.2Â mA |
| LOW | –2.5 mA ... 2.5 mA |
Electrical data - Non-safe inputs
| HIGH | 13Â VÂ DCÂ ... 30Â VÂ DC |
|---|---|
| LOW | 0Â VÂ DCÂ ... 5Â VÂ DC |
| Input current | ≤ 6.2 mA |
Electrical data - Power supply output for external devices
| Supply voltage | 24Â VÂ DC (16.8Â VÂ DCÂ ... 30Â VÂ DC) |
|---|---|
| Output current | ≤ 3.9 A |
Mechanical data
| Dimensions (W x H x D) | 68.15 mm x 48 mm x 18 mm |
|---|---|
| Weight | 28 g (± 5 %) |
Ambient data
| Enclosure rating | IP65 (ENÂ 60529)IP67 (ENÂ 60529) |
|---|---|
| Ambient operating temperature | –25 °C ... +55 °C |
| Storage temperature | –25 °C ... +70 °C |
Certificates
| EU declaration of conformity | ✔ |
|---|---|
| UK declaration of conformity | ✔ |
| ACMA declaration of conformity | ✔ |
| China RoHS | ✔ |
| UK-Type-Examination approval | ✔ |
| cULus certificate | ✔ |
| cTUVus certificate | ✔ |
| EC-Type-Examination approval | ✔ |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | ✔ |
Classifications
| ECLASS 5.0 | 27371990 |
|---|---|
| ECLASS 5.1.4 | 27371990 |
| ECLASS 6.0 | 27371819 |
| ECLASS 6.2 | 27371819 |
| ECLASS 7.0 | 27371819 |
| ECLASS 8.0 | 27371819 |
| ECLASS 8.1 | 27371819 |
| ECLASS 9.0 | 27371819 |
| ECLASS 10.0 | 27371819 |
| ECLASS 11.0 | 27371819 |
| ECLASS 12.0 | 27371819 |
| ETIM 5.0 | EC001449 |
| ETIM 6.0 | EC001449 |
| ETIM 7.0 | EC001449 |
| ETIM 8.0 | EC001449 |
| UNSPSC 16.0901 | 41113704 |