Fast delivery within 72 Hours
Sick DT50-2B215252
Laser distance sensors | Dx50-2 | DT50-2B215252 | Communication interface: IO-Link | Measuring range: 200 mm … 30,000 mm, 90% remission factor, 200 mm … 17,000 mm, 18% reflection factor, 200 mm …..
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Laser distance sensors | Dx50-2 | DT50-2B215252 | Communication interface: IO-Link | Measuring range: 200 mm … 30,000 mm, 90% remission factor, 200 mm … 17,000 mm, 18% reflection factor, 200 mm … 10,000 mm, 6% remission factor | Laser class: 2 | Light source: Laser, red | Minimum response time: 0.83 ms | Digital output: 1 … 2 x push-pull: PNP/NPN | Type of analog output: Current output / voltage output | Multifunctional input (MF): 1 x
Specification
Features
| Measuring range | 200 mm ... 30,000 mm, 90% remission factor 1) 2)200 mm ... 17,000 mm, 18% reflection factor200 mm ... 10,000 mm, 6% remission factor |
|---|---|
| Target | Natural objects |
| Resolution | 100 µm |
| Repeatability | â¥Â 0.5 mm 2) 3) 4) |
| Measurement accuracy | ± 7 mm 4) |
| Response time | 0.83 ms ... 75 ms, 0.83 ms / 3.33 ms / 8.33 ms / 25 ms / 75 ms 5) 6) |
| Switching frequency | 1,000 Hz/250 Hz/100 Hz/33 Hz/11 Hz 5) 6) |
| Output time | 0.33 ms/1.33 ms/3.33 ms/10 ms/30 ms 5) 7) |
| Light source | Laser, red 8) |
| Type of light | Visible red light |
| Typ. light spot size (distance) | 10 mm x 10 mm (at 10 m) |
| Normative reference | IECÂ 60825-1:2014, ENÂ 60825-1:2014 |
| Laser class | 2 |
| Average laser service life (at 25 °C) | 100,000 h |
| Additional function | Set speed: Super Fast ... Super SlowTeach-in, scaling and inversion of analog outputOutput Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivatedSwitching mode: Distance to Object (DtO) / switching window / object between sensor and background (ObSB)Teach-in, scaling and inversion of digital outputMultifunctional input: laser off / external teach / deactivatedReset to factory defaultShape comparison: based on the distance measured over a period of timeHold measurement valueSwitch-off or lock displayEasy teach option |
| MTTFD | 101Â years |
| DCavg | 0% |
Interfaces
| IO-Link | â , IO-Link V1.1, COM3 (230,4Â kBaud) |
|---|---|
| Function | Process data, parameterization, diagnosis, data storage |
| Number | 1Â ... 2Â 1)Â 2)Â 3) |
| Type | Push-pull: PNP/NPN |
| Function | Complementary digital outputs (Q, Ǭ) |
| Maximum output current IA | â¤Â 100 mA |
| Number | 1 |
| Type | Current output / voltage output |
| Function | Output Q2 adaptable: Current output / Voltage output / Digital output / Q1 not / deactivated |
| Current | 4 mA ... 20 mA, â¤Â 450 Ω |
| Voltage | 0 V ... 10 V, â¥Â 50,000 Ω |
| Resolution | 16Â bit |
| Multifunctional input (MF) | 1 x 4) |
| Hysteresis | 0 mm ... 29,950 mm |
Electronics
| Supply voltage UB | DC 10Â VÂ ... 30Â VÂ 1)Â 2) |
|---|---|
| Power consumption | â¤Â 1.7 W 3) |
| Ripple | â¤Â 5 Vpp 4) |
| Initialization time | â¤Â 300 ms |
| Warm-up time | â¤Â 15 min |
| Display | 3Â x LED, LC display |
| Enclosure rating | IP65IP67 |
| Protection class | III |
Mechanics
| Dimensions (W x H x D) | 36.2 mm x 63 mm x 58.6 mm |
|---|---|
| Housing material | Metal (zinc diecast) |
| Window material | Plastic (PMMA) |
| Weight | 235Â g |
Ambient data
| Ambient temperature, operation | â40 °C ... +65 °C, Uv ⤠24 Vâ30 °C ... +140 °C, operation with 2 cooling plates (2055755) / optionally with heat protection filter (2085598) 1) |
|---|---|
| Ambient temperature, storage | â40 °C ... +75 °C |
| Max. rel. humidity (not condensing) | â¤Â 95 % |
| Typ. Ambient light immunity | 40,000Â lx |
| Vibration resistance | (IEC 60068-2-64:2008) Noise test: 20 Hz ... 500 Hz, 10 g RMS, 2 h / axis |
| Shock resistance | (IEC 60068-2-27:2008) 30 g, 11 ms, 3 axes, ± 3 single shocks / axis(IEC 60068-2-27:2008) 10 g, 6 ms, 3 axes, ± 500 shocks / axis(IEC 60068-2-27:2008) 70 g, 6 ms, Y-axis, ± 100,000 shocks |
| Electromagnetic compatibility (EMC) | ENÂ 61000-6-2, ENÂ 61000-6-4Â 2) |
Certificates
| EU declaration of conformity | â |
|---|---|
| UK declaration of conformity | â |
| ACMA declaration of conformity | â |
| Moroccan declaration of conformity | â |
| China RoHS | â |
| cULus certificate | â |
| IO-Link certificate | â |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | â |
Classifications
| ECLASS 5.0 | 27270801 |
|---|---|
| ECLASS 5.1.4 | 27270801 |
| ECLASS 6.0 | 27270801 |
| ECLASS 6.2 | 27270801 |
| ECLASS 7.0 | 27270801 |
| ECLASS 8.0 | 27270801 |
| ECLASS 8.1 | 27270801 |
| ECLASS 9.0 | 27270801 |
| ECLASS 10.0 | 27270801 |
| ECLASS 11.0 | 27270801 |
| ECLASS 12.0 | 27270916 |
| ETIM 5.0 | EC001825 |
| ETIM 6.0 | EC001825 |
| ETIM 7.0 | EC001825 |
| ETIM 8.0 | EC001825 |
| UNSPSC 16.0901 | 41111613 |