Description
System plugs and extension modules | DMM4 | DMM4-AA110A0A0 | Description: The DMM4 extension module extends the functional scope of an electro-sensitive protective equipment (ESPE). The extended functional scope of the ESPE is referred to as function package DMM4. The extension module has several inputs and outputs to which the ESPE and other devices or sensors can be connected. | Compatible devices: deTec4 (30Â mm resolution), deTem4, deTem4 A/P for a specific version number or higher (functional scope) | Functions: The scope of the function package DMM4 depends on the connected ESPE. | Configuration and diagnostics: Via software (Safety Designer) | Safety level: PL e, SIL 3, Type 4 | Connection type: Male connector M12, 8-pin | Items supplied: DMM4 extension moduleUSB protective coverProtective caps for M12 round connectorsSafety instructionMounting instructionsOperating instructions for downloadSafety Designer configuration software for download
Specification
Features
| Description | The DMM4 extension module extends the functional scope of an electro-sensitive protective equipment (ESPE). The extended functional scope of the ESPE is referred to as function package DMM4. The extension module has several inputs and outputs to which the ESPE and other devices or sensors can be connected. |
|---|---|
| Compatible devices | deTec4 (30Â mm resolution), deTem4, deTem4 A/P for a specific version number or higher (functional scope) |
| Sender | V1.1.0Â or higher |
| Receiver | V1.2.0Â or higher |
| Sender | V1.0.0Â or higher |
| Receiver | V1.0.0Â or higher |
| Active unit | V1.1.0Â or higher |
| Items supplied | DMM4 extension moduleUSB protective coverProtective caps for M12 round connectorsSafety instructionMounting instructionsOperating instructions for downloadSafety Designer configuration software for download |
Safety-related parameters
| Type | Type 4Â (IECÂ 61496) |
|---|---|
| Safety integrity level | SIL 3Â (IECÂ 61508, IECÂ 62061) |
| Category | Category 4Â (ISOÂ 13849) |
| Performance level | PL e (ISO 13849) |
| PFHD (mean probability of a dangerous failure per hour) | 3.5Â x 10-9 |
| TM (mission time) | 20Â years (ISOÂ 13849) |
Functions
| Note | The scope of the function package DMM4 depends on the connected ESPE. |
|---|---|
| deTec4 safety light curtain (30Â mm resolution) | Beam codingRestart interlockSmart restart interlockExternal device monitoring (EDM)Application diagnostic output (ADO)CascadingSmart presence detectionReduced resolution (Basic)Manual adjustment of the protective field widthTransmitting power adjustmentMuting (2-signal muting)Muting (4-signal muting)Partial mutingOperating mode selectionConfigurable multiple samplingInputs for safety sensors (SDI) |
| deTem4 safety light-beam sensor | Beam codingRestart interlockExternal device monitoring (EDM)Application diagnostic output (ADO)Manual adjustment of the protective field widthTransmitting power adjustmentMuting (2-signal muting)Muting (4-signal muting)Partial mutingOperating mode selectionInputs for safety sensors (SDI) |
| deTem4 A/P safety light-beam sensor | Beam codingRestart interlockExternal device monitoring (EDM)Application diagnostic output (ADO)Muting (2-signal muting)Muting (4-signal muting)Operating mode selectionInputs for safety sensors (SDI) |
Interfaces
| System connection | Male connector M12, 8-pin |
|---|---|
| Sender connection | Female connector M12, 8-pin |
| Receiver connection or active unit | Female connector M12, 8-pin |
| Muting sensors connection (A1, A2, B1, B2) | 4 × M12 female connector, 5-pin |
| Device connections (X1, X2, X3) | 3 × M12 male connector, 5-pin |
| Configuration and diagnostics | USB 2.0Â Type-C |
| Configuration method | Via software (Safety Designer) |
| Display elements | Status LEDs |
Electronics
| Protection class | III (IECÂ 61140) |
|---|---|
| Supply voltage VS | 24Â VÂ DC (19.2Â VÂ ... 28.8Â V) |
| Residual ripple | ≤ 10 % 1) |
Mechanics
| Dimensions (W x H x D) | 35.4 mm x 290.2 mm x 33 mm |
|---|
Ambient data
| Enclosure rating | IP65 / IP67 (IECÂ 60529) |
|---|---|
| Ambient operating temperature | –30 °C ... +55 °C |
| Storage temperature | –30 °C ... +70 °C |
| Air humidity | 15Â %Â ... 95Â %, Non-condensing |
| Vibration resistance | 5 … 150 Hz, 3,5 mm / 1 g (EN 60068-2-6) |
| Shock resistance | 15Â g / 6Â ms (ENÂ 60068-2-27) |
| Class | 3M4 (IECÂ TR 60721-4-3) |
| EMC | According to IECÂ 61496-1, IECÂ 61000-6-2, IECÂ 61000-6-4 |
Certificates
| EU declaration of conformity | ✔ |
|---|---|
| UK declaration of conformity | ✔ |
| ACMA declaration of conformity | ✔ |
| Moroccan declaration of conformity | ✔ |
| China RoHS | ✔ |
| ULus approval | ✔ |
| cUL approval | ✔ |
| EC-Type-Examination approval | ✔ |
| Information according to Art. 3 of Data Act (Regulation EU 2023/2854) | ✔ |
Classifications
| ECLASS 5.0 | 27272790 |
|---|---|
| ECLASS 5.1.4 | 27272790 |
| ECLASS 6.0 | 27272790 |
| ECLASS 6.2 | 27272790 |
| ECLASS 7.0 | 27272790 |
| ECLASS 8.0 | 27272790 |
| ECLASS 8.1 | 27272790 |
| ECLASS 9.0 | 27272792 |
| ECLASS 10.0 | 27272792 |
| ECLASS 11.0 | 27272792 |
| ECLASS 12.0 | 27272792 |
| ETIM 5.0 | EC011349 |
| ETIM 6.0 | EC011349 |
| ETIM 7.0 | EC011349 |
| ETIM 8.0 | EC011349 |
| UNSPSC 16.0901 | 41113704 |

Reviews