Fast delivery within 72 Hours

Sick DMM4-AA110A0A0

System plugs and extension modules | DMM4 | DMM4-AA110A0A0 | Description: The DMM4 extension module extends the functional scope of an electro-sensitive protective equipment (ESPE). The extended funct…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

System plugs and extension modules | DMM4 | DMM4-AA110A0A0 | Description: The DMM4 extension module extends the functional scope of an electro-sensitive protective equipment (ESPE). The extended functional scope of the ESPE is referred to as function package DMM4. The extension module has several inputs and outputs to which the ESPE and other devices or sensors can be connected. | Compatible devices: deTec4 (30 mm resolution), deTem4, deTem4 A/P for a specific version number or higher (functional scope) | Functions: The scope of the function package DMM4 depends on the connected ESPE. | Configuration and diagnostics: Via software (Safety Designer) | Safety level: PL e, SIL 3, Type 4 | Connection type: Male connector M12, 8-pin | Items supplied: DMM4 extension moduleUSB protective coverProtective caps for M12 round connectorsSafety instructionMounting instructionsOperating instructions for downloadSafety Designer configuration software for download

Specification

Features

DescriptionThe DMM4 extension module extends the functional scope of an electro-sensitive protective equipment (ESPE). The extended functional scope of the ESPE is referred to as function package DMM4. The extension module has several inputs and outputs to which the ESPE and other devices or sensors can be connected.
Compatible devicesdeTec4 (30Â mm resolution), deTem4, deTem4 A/P for a specific version number or higher (functional scope)
SenderV1.1.0Â or higher
ReceiverV1.2.0Â or higher
SenderV1.0.0Â or higher
ReceiverV1.0.0Â or higher
Active unitV1.1.0Â or higher
Items suppliedDMM4 extension moduleUSB protective coverProtective caps for M12 round connectorsSafety instructionMounting instructionsOperating instructions for downloadSafety Designer configuration software for download

Safety-related parameters

TypeType 4Â (IECÂ 61496)
Safety integrity levelSIL 3Â (IECÂ 61508, IECÂ 62061)
CategoryCategory 4Â (ISOÂ 13849)
Performance levelPL e (ISO 13849)
PFHD (mean probability of a dangerous failure per hour)3.5Â x 10-9
TM (mission time)20Â years (ISOÂ 13849)

Functions

NoteThe scope of the function package DMM4 depends on the connected ESPE.
deTec4 safety light curtain (30Â mm resolution)Beam codingRestart interlockSmart restart interlockExternal device monitoring (EDM)Application diagnostic output (ADO)CascadingSmart presence detectionReduced resolution (Basic)Manual adjustment of the protective field widthTransmitting power adjustmentMuting (2-signal muting)Muting (4-signal muting)Partial mutingOperating mode selectionConfigurable multiple samplingInputs for safety sensors (SDI)
deTem4 safety light-beam sensorBeam codingRestart interlockExternal device monitoring (EDM)Application diagnostic output (ADO)Manual adjustment of the protective field widthTransmitting power adjustmentMuting (2-signal muting)Muting (4-signal muting)Partial mutingOperating mode selectionInputs for safety sensors (SDI)
deTem4 A/P safety light-beam sensorBeam codingRestart interlockExternal device monitoring (EDM)Application diagnostic output (ADO)Muting (2-signal muting)Muting (4-signal muting)Operating mode selectionInputs for safety sensors (SDI)

Interfaces

System connectionMale connector M12, 8-pin
Sender connectionFemale connector M12, 8-pin
Receiver connection or active unitFemale connector M12, 8-pin
Muting sensors connection (A1, A2, B1, B2)4 × M12 female connector, 5-pin
Device connections (X1, X2, X3)3 × M12 male connector, 5-pin
Configuration and diagnosticsUSB 2.0Â Type-C
Configuration methodVia software (Safety Designer)
Display elementsStatus LEDs

Electronics

Protection classIII (IECÂ 61140)
Supply voltage VS24Â VÂ DC (19.2Â VÂ ... 28.8Â V)
Residual ripple≤ 10 % 1)

Mechanics

Dimensions (W x H x D)35.4 mm x 290.2 mm x 33 mm

Ambient data

Enclosure ratingIP65 / IP67 (IECÂ 60529)
Ambient operating temperature–30 °C ... +55 °C
Storage temperature–30 °C ... +70 °C
Air humidity15Â %Â ... 95Â %, Non-condensing
Vibration resistance5 … 150 Hz, 3,5 mm / 1 g (EN 60068-2-6)
Shock resistance15Â g / 6Â ms (ENÂ 60068-2-27)
Class3M4 (IECÂ TR 60721-4-3)
EMCAccording to IECÂ 61496-1, IECÂ 61000-6-2, IECÂ 61000-6-4

Certificates

EU declaration of conformity✔
UK declaration of conformity✔
ACMA declaration of conformity✔
Moroccan declaration of conformity✔
China RoHS✔
ULus approval✔
cUL approval✔
EC-Type-Examination approval✔
Information according to Art. 3 of Data Act (Regulation EU 2023/2854)✔

Classifications

ECLASS 5.027272790
ECLASS 5.1.427272790
ECLASS 6.027272790
ECLASS 6.227272790
ECLASS 7.027272790
ECLASS 8.027272790
ECLASS 8.127272790
ECLASS 9.027272792
ECLASS 10.027272792
ECLASS 11.027272792
ECLASS 12.027272792
ETIM 5.0EC011349
ETIM 6.0EC011349
ETIM 7.0EC011349
ETIM 8.0EC011349
UNSPSC 16.090141113704