Fast delivery within 72 Hours

Keyence MP-FEA1

Energy Monitor Main Unit. MP-FEA1. Series: Air Quality Multi-Sensor. Series code: MP-F series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Energy Monitor Main Unit. MP-FEA1. Series: Air Quality Multi-Sensor. Series code: MP-F series

Specification

Model Name

Energy Monitor Main Unit

Model Code

MP-FEA1

Series Title

Air Quality Multi-Sensor

Series Code

MP-F series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157145&dlModelId=PM_276FEA1&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/process/flow/mp-f/downloads/?mode=cd&modelId=PM_276FEA1

Manuals URL

https://www.keyence.com/products/process/flow/mp-f/downloads/?mode=ma&modelId=PM_276FEA1

Model

MP-FEA1

Measurement specifications - Electrical service type

1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire (switchable)

Measurement specifications - Number of measurement circuits

1 (up to 2 circuits with the 1-phase 2-wire setting *1)

Input specifications - Primary-side rated current, In

When using specialized CT MP-FEC100: 100 A Or, general CT (secondary-side rated input current 1 A) *2When using specialized CT MP-FEC250: 250 A Or, general CT (secondary-side rated input current 1 A) *2When using specialized CT MP-FEC600: 600 A Or, general CT (secondary-side rated input current 1 A) *2When using specialized CT MP-FEC50M: 50 AWhen using specialized CT MP-FEC100M: 100 A

Input specifications - Over current withstand capability

1.2 times the primary-side rated current (can be applied consecutively), 10 times the primary-side rated current (for 1 second or less)

Input specifications - Rated input voltage(direct input)

・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 277 VAC (L-N)・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N)

Input specifications

・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L)・MP-FEC50M/MP-FEC100M in use: 100 to 240 VAC (L-N), 200 to 480 VAC (L-L)

Input specifications - Maximum permissible voltage to earth

・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: 480 VAC to earth・MP-FEC50M/MP-FEC100M in use: 240 VAC to earth

Input specifications - Input voltage fluctuation range

−15% to +15% of the rated input voltage

Input specifications - Rated input frequency

50/60 Hz

Displayable range/Display resolution(Main Unit) - Voltage

Display resolution 0.1 [V]

Displayable range/Display resolution(Main Unit) - Current

Display resolution 0.001 [A]

Displayable range/Display resolution(Main Unit) - Active power/reactive power/apparent power

-8942.400 to +8942.400 [kW/kvar/kVA], display resolution 0.001 [kW/kvar/kVA]

Displayable range/Display resolution(Main Unit) - Active energy/reactive energy/apparent energy

0.000 to 999999.999 [kWh/kvarh/kVAh], display resolution 0.001 [kWh/kvarh/kVAh]

Displayable range/Display resolution(Main Unit) - Power factor (PF)

-1.00 to 1.00, display resolution 0.01

Displayable range/Display resolution(Main Unit) - Frequency

0.0 to 90.0 [Hz], display resolution 0.1 [Hz]

Measurement accuracy - Voltage

±0.5% of RD (within rated input voltage) *3

Measurement accuracy - Current

・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3・MP-FEC50M/MP-FEC100M in use: ±0.5% of F.S. *3

Measurement accuracy - Active energy

・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-22 §7.9 table 3 class 0.5 *2 *3Power factor 1: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%)Power factor 0.5 inductive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%)Power factor 0.8 capacitive: ±0.6% of RD (10% ≤ In ≤ 120%), ±1.0% of RD (2% ≤ In < 10%)・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (1% ≤ In ≤ 120%) *3

Measurement accuracy - Reactive energy

・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: Compliant with IEC 62053-23 §7.9 table 3 class 2 *2 *3Reactive power factor 1: ±2.0% of RD (5% ≤ In ≤ 120%), ±2.5% of RD (1% ≤ In < 5%)Reactive power factor 0.5 inductive or capacitive: ±2.0% of RD (10% ≤ In ≤ 120%), ±2.5% of RD (5% ≤ In < 10%)Reactive power factor 0.25 inductive or capacitive: ±2.5% of RD (10% ≤ In ≤ 120%)・MP-FEC50M/MP-FEC100M in use: ±2.0% of RD (5% ≤ In ≤ 120%) *3

Measurement accuracy - Apparent energy

・MP-FEC100/MP-FEC250/MP-FEC600, or general CT in use: ±0.5% of RD (5% ≤ In ≤ 120%), ±1.0% of RD (1% ≤ In < 5%) *2 *3・MP-FEC50M/MP-FEC100M in use: ±1.0% of RD (5% ≤ In ≤ 120%) *3 *4

Measurement accuracy - Effect of ambient temperature

±0.03%/K *3 *5

Measurement accuracy - Effect of harmonics

±0.5% of RD *3 *6

Measurement accuracy - Power factor (PF)

±0.01 *3

Measurement accuracy - Power

±0.1 [Hz] *3

Current consumption

36 mA

Withstand voltage

Across all terminals and housing: 2500 VAC for 1 minuteAcross voltage measurement terminal and communication terminal: 2500 VAC for 1 minuteAcross CT input terminal and communication terminal (When using a specialized CT): 2500 V for 1 minute

Insulation resistance

Across all terminals and housing: 20 MΩ min. (500 VDC)Across voltage measurement terminal and CT input terminal and across communication terminal: 20 MΩ min. (500 VDC)

Environmental resistance - Ambient temperature

-5 to +55°C 23 to 131°F (no freezing)

Environmental resistance - Relative humidity

35%RH to 85%RH (no condensation)

Environmental resistance - Measurement category

II

Environmental resistance - Altitude

2500 m or less

Environmental resistance - Pollution degree

2

Environmental resistance - Mounting method

DIN rail mounting

Environmental resistance - Vibration resistance

10 to 500 Hz, power spectral concentration: 0.033G2/Hz, XYZ axes

Environmental resistance - Shock resistance

150 m/s2, 2 times each for X, Y, and Z axes

Material

Polycarbonate

Weight

Approx. 110 g 3.88 oz

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence MP-FEA1”

Your email address will not be published. Required fields are marked *