Fast delivery within 72 Hours

Keyence KV-NC4TP

Temperature input unit,input: 4. KV-NC4TP. Series: Programmable Logic Controller. Series code: KV-X series

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Temperature input unit,input: 4. KV-NC4TP. Series: Programmable Logic Controller. Series code: KV-X series

Specification

Model Name

Temperature input unit,input: 4

Model Code

KV-NC4TP

Series Title

Programmable Logic Controller

Series Code

KV-X series

Data Sheet URL

https://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157158&dlModelId=PM_084N4TP&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US

CAD URL

https://www.keyence.com/products/controls/plc-building-block-type/kv-x/downloads/?mode=cd&modelId=PM_084N4TP

Manuals URL

https://www.keyence.com/products/controls/plc-building-block-type/kv-x/downloads/?mode=ma&modelId=PM_084N4TP

Model

KV-NC4TP

Temperature input unit - Number of inputs

4 *1

Temperature input unit - Input

Thermocouple, Platinum resistance thermometer

Temperature input unit - Input range

K: -270.0 to 1372.0°C -454 to 2501.6°FJ: -210.0 to 1200.0°C -346 to 2192°FT: -270.0 to 400.0°C -454 to 752°FE: -270.0 to 1000.0°C -454 to 1832°FN: -270.0 to 1300.0°C -454 to 2372°FR: -50.0 to 1768.0°C -58 to 3214.4°FS: -50.0 to 1768.0°C -58 to 3214.4°FB: 0.0 to 1820.0°C 32 to 3308°FWRe5-26: 0.0 to 2315.0°C 32 to 4199°F

Temperature input unit

Pt100: -200.0 to 850.0°C -328 to 1562°FJPt100: -200.0 to 600.0°C -328 to 1112°F

Temperature input unit - Overall accuracy

±(0.2% of F.S. +1°C 1.8°F) (at 25°C ±5°C 77°F ±9°F)±(0.4% of F.S. +1°C 1.8°F) (at 0 to 55°C 32 to 131°F)

Temperature input unit - Allowable wiring resistance

100 Ω max./wire(no variation allowed among three wires)

Temperature input unit - Conversion speed

125 ms/channel

Temperature input unit - Isolation method

Between input terminals and base unit:Photocoupler/semiconductor relay/transformer isolationBetween channels: (When resistance thermometer is not used):Semiconductor relay isolation;(When resistance thermometer is used): No isolation

Temperature input unit - Special function

Channel skip, disconnection detection,averaging (time average, count average, moving average),special data offset, peak-/bottom-hold, alarm,abnormal input setting

Internal current consumption

40 mA or less

Weight

Approx. 110 g

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Keyence KV-NC4TP”

Your email address will not be published. Required fields are marked *