Long-range sensor main unit 2-wire standard model. FR-LW20L. Series: Radar Level Sensor. Series code: FR series

Specification

Model NameLong-range sensor main unit 2-wire standard model
Model CodeFR-LW20L
Series TitleRadar Level Sensor
Series CodeFR series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157159&dlModelId=PM_28LW20L&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/level/fr/downloads/?mode=cd&modelId=PM_28LW20L
Manuals URLhttps://www.keyence.com/products/process/level/fr/downloads/?mode=ma&modelId=PM_28LW20L
ModelFR-LW20L
Type2-wire standard model
Measuring rangeUp to 15 m 49.2’*1
Display rangeUp to 25 m 82.0’*1
Measurable dielectric constant of medium2 or more*2
Resolution1 mm 0.04″
PrecisionUp to 0.1 m 0.3′: ±10 mm 0.39″;0.1 to 10 m 0.3′ to 32.8′ : ±1 mm 0.04″;10 to 20 m 32.8′ to 65.6′: ±2 mm 0.08″*3
Response time1 s, 4 s (default value), 10 s, 25 s
Tank pressure-0.1 to +1 MPa (-0.1 to +0.1 MPa below -20°C -4°F)
Material - Tank interiorLens: PTFE;Internal seal: FKM;Fastener: SUS304
Material - HousingPPS PC PA
Connection diameterG1-1/2 (40A)
Output - No. of control outputs1
Output - Control output/auxiliary outputTransistor output (NPN open collector)Common independent type 35 VDC or less, 50 mA max.Residual voltage of 4.0 V or less (50 mA or less) N.O./N.C. switching
Output - Analog output4 to 20 mA (Response time: 3 s after internal value is confirmed [90% response])
Network compatibilityHART
Analog output accuracy - Resolution1 mm 0.04″*4
Analog output accuracy - Zero accuracy±0.1 mA (zero point = 4 mA)*4
Analog output accuracy - F.S. accuracy±0.2 mA (full scale = 20 mA)*4
Power supply - Power voltage18.3 to 35 VDC.
Power supply - Power consumption752.5 mW or less (including analog output; excluding load current)
Environmental resistance - Ambient temperature-30 to +60°C -22 to 140°F (no freezing)
Environmental resistance - Relative humidityUp to 85% RH (no condensation)
Environmental resistance - Temperature of coupling used-30 to +85°C -22 to 185°F (no freezing)
Environmental resistance - Vibration resistance10 to 500 Hz; Power spectral density: 0.816 G2 X, Y and Z directions
Environmental resistance - Shock resistance100 m/s2 (10 G), 16 ms pulses, 1000 times each in X, Y and Z directions
Enclosure ratingIP67 (IEC60529), Enclosure Type 4X (NEMA250)
Protection circuitReverse power connection protection, power supply surge protection, output short-circuit protection, output surge protection
WeightApprox. 920 g 32.45 oz