Vibration sensor. Vibration sensor with safety function both for the analog current output and for the 2 relay outputs with adjustable swichting thresholds, Series: Performance Plus Line, Measured variable: Vibration velocity, Safety Integrity Level (SIL): SIL 2, Output type: relay, Output type: relay, Output type: analog output, current output of the vibration variable, Equipment protection level Gb: IECEx ULD 22.0031X, Equipment protection level Db: IECEx ULD 22.0031X, Equipment protection level Gb: UL 22 ATEX 2869 X. Type: Vibration sensor. Measuring technology: MEMS. Series: Performance Plus Line. Measured variable: Vibration velocity. Measuring range: . Vibration velocityv-rms0 … 16 mm/s: v-rms. Vibration velocity: 0 … 16 mm/s. Measurement accuracy: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s. Cross-sensitivity: < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis. Frequency range: 10 … 1000 Hz. Averaging time: for v-rms: 2 s. Safety Integrity Level (SIL): SIL 2. Performance level (PL): PL d. Category: Cat. 2. MTTFd: 329 a. Mission Time (TM): 10 a. Diagnostic Coverage (DC): min. 90 %. Status indicator: 6 LEDs for operating states. Control elements: 4 rotary switches and 1 push button for programming. Fusing: external fuse is required: 3 A , semi-time-lag , 30 V DC. Operating voltage: 24 V DC + 7 % / – 10 %. Current consumption: max. 100 mA. Power consumption: 2.6 W. Time delay before availability: 15 s (initially self-test functions are executed before safe measured values are available at the output). Surge protection: up to 2 kV. Output type: relay. Switching function: Normally open (NO). Switching voltage: max. 30 V DC. Switching current: max. 1 A. Output type: relay. Switching function: Normally open (NO). Switching voltage: max. 30 V DC. Switching current: max. 1 A. Output type: analog output, current output of the vibration variable. Output current: 4 … 20 mA. Load resistor: ≤ 500 Ω. Degree of protection: DIN EN 60529, IP66, IP67. Shock resistance: DIN EN 60068-2-27, 60 g, 6 ms. Vibration resistance: DIN EN 60068-2-6, 16.5 g, 10 … 1000 Hz. Vibration evaluation: DIN ISO 10816/20816. Functional safety: DIN EN IEC 61508 , SIL 2 EN ISO 13849 , PL d. IECEx approval: . Equipment protection level GbIECEx ULD 22.0031XEquipment protection level DbIECEx ULD 22.0031X: . Equipment protection level Gb: IECEx ULD 22.0031X. Equipment protection level Db: IECEx ULD 22.0031X. ATEX approval: . Equipment protection level GbUL 22 ATEX 2869 XEquipment protection level DbUL 22 ATEX 2869 X: . Equipment protection level Gb: UL 22 ATEX 2869 X. Equipment protection level Db: UL 22 ATEX 2869 X. Ambient temperature: -40 … 60 °C (-40 … 140 °F). Measuring head temperature: -40 … 85 °C (-40 … 185 °F) directly at the mounting point. Storage temperature: -40 … 60 °C (-40 … 140 °F). Connection type: cable. Housing material: Stainless steel 1.4305 / AISI 303. Degree of protection: IP66 / IP67 only in connected state and correctly mounted housing cover. Cable: . Number of cores8LengthL2 m: . Number of cores: 8. Length: 2 m. Mass: 880 g. Dimensions: . Height46 mmWidth62 mmLength77.3 mm: . Height: 46 mm. Width: 62 mm. Length: 77.3 mm. Scope of delivery: 1 x allen head screw M8 x 20 1 x spring washer M8 1 x seal label. Use in the hazardous area: see instruction manuals Only use accessories specified by the manufacturer.

Specification

General specifications

TypeVibration sensor
Measuring technologyMEMS
SeriesPerformance Plus Line
Measured variableVibration velocity
Measuring range
Vibration velocityv-rms0 ... 16 mm/sv-rms
Vibration velocity0 ... 16 mm/s
Measurement accuracy± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
Frequency range10 ... 1000 Hz
Averaging timefor v-rms: 2 s

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
Performance level (PL)PL d
CategoryCat. 2
MTTFd329 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)min. 90 %

Indicators/operating means

Status indicator6 LEDs for operating states
Control elements4 rotary switches and 1 push button for programming

Electrical specifications

Fusingexternal fuse is required: 3 A , semi-time-lag , 30 V DC
Operating voltage24 V DC + 7 % / - 10 %
Current consumptionmax. 100 mA
Power consumption2.6 W
Time delay before availability15 s (initially self-test functions are executed before safe measured values are available at the output)
Surge protectionup to 2 kV

Output 1

Output typerelay
Switching functionNormally open (NO)
Switching voltagemax. 30 V DC
Switching currentmax. 1 A

Output 2

Output typerelay
Switching functionNormally open (NO)
Switching voltagemax. 30 V DC
Switching currentmax. 1 A

Output 3

Output typeanalog output, current output of the vibration variable
Output current4 ... 20 mA
Load resistor≤ 500 Ω

Standard conformity

Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz
Vibration evaluationDIN ISO 10816/20816
Functional safetyDIN EN IEC 61508 , SIL 2 EN ISO 13849 , PL d

Approvals and certificates

IECEx approval
Equipment protection level GbIECEx ULD 22.0031XEquipment protection level DbIECEx ULD 22.0031X
Equipment protection level GbIECEx ULD 22.0031X
Equipment protection level DbIECEx ULD 22.0031X
ATEX approval
Equipment protection level GbUL 22 ATEX 2869 XEquipment protection level DbUL 22 ATEX 2869 X
Equipment protection level GbUL 22 ATEX 2869 X
Equipment protection level DbUL 22 ATEX 2869 X

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Measuring head temperature-40 ... 85 °C (-40 ... 185 °F) directly at the mounting point
Storage temperature-40 ... 60 °C (-40 ... 140 °F)

Mechanical specifications

Connection typecable
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state and correctly mounted housing cover
Cable
Number of cores8LengthL2 m
Number of cores8
Length2 m
Mass880 g
Dimensions
Height46 mmWidth62 mmLength77.3 mm
Height46 mm
Width62 mm
Length77.3 mm

General information

Scope of delivery1 x allen head screw M8 x 20 1 x spring washer M8 1 x seal label
Use in the hazardous areasee instruction manuals Only use accessories specified by the manufacturer.