Fast delivery within 72 Hours

Pepperl Fuchs VIM62PL-E1T16-0ME-I420V14

Vibration sensor. Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity
Temperature, Output type: analog…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Vibration sensor. Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity Temperature, Output type: analog output, current output of the vibration variable, Output type: analog output, current output of the temperature. Type: Vibration sensor. Measuring technology: MEMS. Series: Performance Line. Measured variable: Vibration velocity Temperature. Measuring range: . Vibration velocityv-rms0 … 16 mm/sTemperature-40 … 125 °C (-40 … 257 °F): v-rms. Vibration velocity: 0 … 16 mm/s. Temperature: -40 … 125 °C (-40 … 257 °F). Measurement accuracy: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s. Cross-sensitivity: < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis. Frequency range: 10 … 1000 Hz. Averaging time: for v-rms: 2 s. Fusing: external fuse is required: 3 A , semi-time-lag , 30 V DC. Operating voltage: 10 … 30 V DC. Current consumption: max. 50 mA. Power consumption: max. 750 mW. Time delay before availability: 10 s (rms filter is calculated intially with measurement data before they are available at the output). Surge protection: up to 2 kV. Output type: analog output, current output of the vibration variable. Output current: 4 … 20 mA. Load resistor: ≤ 500 Ω. Output type: analog output, current output of the temperature. Output current: 4 … 20 mA. Load resistor: ≤ 500 Ω. Degree of protection: DIN EN 60529, IP66, IP67. Shock resistance: DIN EN 60068-2-27, 60 g, 6 ms. Vibration resistance: DIN EN 60068-2-6, 16.5 g, 10 … 1000 Hz. Vibration evaluation: DIN ISO 10816/20816. UL approval: . Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on requestMaximum permissible ambient temperaturemax. 60 °C (max. 140 °F): . Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request. Maximum permissible ambient temperature: max. 60 °C (max. 140 °F). Ambient temperature: -40 … 60 °C (-40 … 140 °F). Measuring head temperature: -40 … 125 °C (-40 … 257 °F) directly at the mounting point. Storage temperature: -40 … 60 °C (-40 … 140 °F). Connection type: plug. Housing material: Stainless steel 1.4305 / AISI 303. Degree of protection: IP66 / IP67 only in connected state. Connector: . ThreadingM12Number of pins4: . Threading: M12. Number of pins: 4. Mass: approx. 200 g. Dimensions: . Length82.35 mmDiameter31 mm: . Length: 82.35 mm. Diameter: 31 mm

Specification

General specifications

TypeVibration sensor
Measuring technologyMEMS
SeriesPerformance Line
Measured variableVibration velocity Temperature
Measuring range
Vibration velocityv-rms0 ... 16 mm/sTemperature-40 ... 125 °C (-40 ... 257 °F)v-rms
Vibration velocity0 ... 16 mm/s
Temperature-40 ... 125 °C (-40 ... 257 °F)
Measurement accuracy± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
Frequency range10 ... 1000 Hz
Averaging timefor v-rms: 2 s

Electrical specifications

Fusingexternal fuse is required: 3 A , semi-time-lag , 30 V DC
Operating voltage10 ... 30 V DC
Current consumptionmax. 50 mA
Power consumptionmax. 750 mW
Time delay before availability10 s (rms filter is calculated intially with measurement data before they are available at the output)
Surge protectionup to 2 kV

Output 1

Output typeanalog output, current output of the vibration variable
Output current4 ... 20 mA
Load resistor≤ 500 Ω

Output 2

Output typeanalog output, current output of the temperature
Output current4 ... 20 mA
Load resistor≤ 500 Ω

Standard conformity

Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz
Vibration evaluationDIN ISO 10816/20816

Approvals and certificates

UL approval
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on requestMaximum permissible ambient temperaturemax. 60 °C (max. 140 °F)
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request
Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Measuring head temperature-40 ... 125 °C (-40 ... 257 °F) directly at the mounting point
Storage temperature-40 ... 60 °C (-40 ... 140 °F)

Mechanical specifications

Connection typeplug
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state
Connector
ThreadingM12Number of pins4
ThreadingM12
Number of pins4
Massapprox. 200 g
Dimensions
Length82.35 mmDiameter31 mm
Length82.35 mm
Diameter31 mm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Pepperl Fuchs VIM62PL-E1T16-0ME-I420V14”

Your email address will not be published. Required fields are marked *