AS-Interface sensor/actuator module. KE1 switch cabinet module, 4 inputs and 4 outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V3.0. Profile: S-7.A.7. IO code7ID codeAID1 code7ID2 code7: . IO code: 7. ID code: A. ID1 code: 7. ID2 code: 7. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of outputs. LED PWR: AS-Interface voltage; LED green. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 4 LED yellow. Auxiliary voltage (output): 20 … 30 V DC PELV. Rated operating voltage: 26.5 … 31.6 V from AS-Interface. Rated operating current: ≤ 40 mA. Protection class: III. Surge protection: UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts. Supply: from external auxiliary voltage UAUX. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Signal delay: < 2 ms (input/AS-Interface). Signal frequency: ≤ 250 Hz. Number/Type: 4 electronic outputs, PNP, overload and short-circuit proof. Supply: from external auxiliary voltage UAUX. Voltage: ≥ (UAUX – 0.5 V). Current: 0.5 A per output , 2 A per module. Usage category: DC-13. Electromagnetic compatibility: . Directive 2014/30/EUIEC 62026-2:2015 EN 61326-1:2006: . Directive 2014/30/EU: IEC 62026-2:2015 EN 61326-1:2006. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2015. Emitted interference: EN 55011:2009. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61326-1:2006. Ambient temperature: -25 … 60 °C (-13 … 140 °F). Storage temperature: -25 … 85 °C (-13 … 185 °F). Relative humidity: 90 % , noncondensing. Pollution degree: 2. Degree of protection: IP20. Connection: removable spring double terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 … 1.5 mm2recommended tools for 1.5 mm2: PxC CRIMPFOX ZA3 or Weidmüller PZ 6 roto. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 80 g. Dimensions: . Height48.5 mmWidth22.5 mmLength99.6 mm: . Height: 48.5 mm. Width: 22.5 mm. Length: 99.6 mm. Mounting: DIN mounting rail
Specification
General specifications
| Node type | A/B node |
|---|---|
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V3.0 |
| Profile | S-7.A.7 |
| IO code7ID codeAID1 code7ID2 code7 | |
| IO code | 7 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 7 |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: overload of outputs |
|---|---|
| LED PWR | AS-Interface voltage; LED green |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 4 LED yellow |
Electrical specifications
| Auxiliary voltage (output) | 20 ... 30 V DC PELV |
|---|---|
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current | ≤ 40 mA |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts |
|---|---|
| Supply | from external auxiliary voltage UAUX |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA | |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
| Signal delay | < 2 ms (input/AS-Interface) |
| Signal frequency | ≤ 250 Hz |
Output
| Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
|---|---|
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | 0.5 A per output , 2 A per module |
| Usage category | DC-13 |
Directive conformity
| Electromagnetic compatibility | |
|---|---|
| Directive 2014/30/EUIEC 62026-2:2015 EN 61326-1:2006 | |
| Directive 2014/30/EU | IEC 62026-2:2015 EN 61326-1:2006 |
Standard conformity
| Degree of protection | EN 60529:2000 |
|---|---|
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2015 |
| Emitted interference | EN 55011:2009 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61326-1:2006 |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
|---|---|
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 90 % , noncondensing |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 |
|---|---|
| Connection | removable spring double terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2recommended tools for 1.5 mm2: PxC CRIMPFOX ZA3 or Weidmüller PZ 6 roto |
| Material | |
| HousingPA 66-FR | |
| Housing | PA 66-FR |
| Mass | 80 g |
| Dimensions | |
| Height48.5 mmWidth22.5 mmLength99.6 mm | |
| Height | 48.5 mm |
| Width | 22.5 mm |
| Length | 99.6 mm |
| Mounting | DIN mounting rail |

Reviews