Fast delivery within 72 Hours

Pepperl Fuchs VBA-4E4A-KE-ZEJQ/E2L

AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs and 4 outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V3.0. Profile: S-7.A.7….

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs and 4 outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V3.0. Profile: S-7.A.7. IO code7ID codeAID1 code7ID2 code7: . IO code: 7. ID code: A. ID1 code: 7. ID2 code: 7. UL File Number: E223772. LED FAULT: Error display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs. LED INT: Internal input supply active; LED green. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 4 LED yellow. LED OUT: switching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption. Auxiliary voltage (input): 12 … 30 V DC PELV. Auxiliary voltage (output): 20 … 30 V DC PELV. Rated operating voltage: 26.5 … 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA (without sensors) / max. 190 mA. Protection class: III. Surge protection: UEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT). Voltage: 21 … 31 V DC (INT). Current loading capacity: ≤ 150 mA, overload- and short-circuit protected (INT). Input current: ≤ 9 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 3 mA1 (attenuated)≥ 5 mA: . 0 (unattenuated): ≤ 3 mA. 1 (attenuated): ≥ 5 mA. Signal delay: < 1 ms (input/AS-Interface). Number/Type: 4 electronic outputs, PNP, overload and short-circuit proof. Supply: from external auxiliary voltage UAUX. Voltage: ≥ (UAUX – 0.5 V). Current: 2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap). Usage category: DC-13. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2004. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013. Ambient temperature: -25 … 60 °C (-13 … 140 °F). Storage temperature: -25 … 85 °C (-13 … 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 … 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 … 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 150 g. Dimensions: . Height99 mmWidth22.5 mmLength102 mm: . Height: 99 mm. Width: 22.5 mm. Length: 102 mm. Mounting: DIN mounting rail. Tightening torque of clamping screws: 0.5 Nm … 0.6 Nm

Specification

General specifications

Node typeA/B node
AS-Interface specificationV3.0
Required gateway specification≥ V3.0
ProfileS-7.A.7
IO code7ID codeAID1 code7ID2 code7
IO code7
ID codeA
ID1 code7
ID2 code7
UL File NumberE223772

Indicators/operating means

LED FAULTError display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs
LED INTInternal input supply active; LED green
LED PWRAS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0
LED AUXext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage
LED INswitching state (input); 4 LED yellow
LED OUTswitching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption

Electrical specifications

Auxiliary voltage (input)12 ... 30 V DC PELV
Auxiliary voltage (output)20 ... 30 V DC PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 35 mA (without sensors) / max. 190 mA
Protection classIII
Surge protectionUEXT, UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV)

Input

Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
Voltage21 ... 31 V DC (INT)
Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT)
Input current≤ 9 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 3 mA1 (attenuated)≥ 5 mA
0 (unattenuated)≤ 3 mA
1 (attenuated)≥ 5 mA
Signal delay< 1 ms (input/AS-Interface)

Output

Number/Type4 electronic outputs, PNP, overload and short-circuit proof
Supplyfrom external auxiliary voltage UAUX
Voltage≥ (UAUX - 0.5 V)
Current2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap)
Usage categoryDC-13

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007

Standard conformity

Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2004
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013

Ambient conditions

Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree2

Mechanical specifications

Degree of protectionIP20
Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material
HousingPA 66-FR
HousingPA 66-FR
Mass150 g
Dimensions
Height99 mmWidth22.5 mmLength102 mm
Height99 mm
Width22.5 mm
Length102 mm
MountingDIN mounting rail
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Pepperl Fuchs VBA-4E4A-KE-ZEJQ/E2L”