AS-Interface sensor/actuator module. KE1 switch cabinet module, 4 inputs. Node type: A/B node. AS-Interface specification: V2.1. Required gateway specification: ≥ V2.0. Profile: S-0.A.0. IO code0ID codeAID1 code7ID2 code0: . IO code: 0. ID code: A. ID1 code: 7. ID2 code: 0. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 4 LED yellow. Rated operating voltage: 26.5 … 31.6 V from AS-Interface. Rated operating current: ≤ 25 mA (without sensors) / max. 60 mA. Protection class: III. Surge protection: Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts. Supply: from AS-Interface. Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Signal delay: < 2 ms (input/AS-Interface). Signal frequency: ≤ 250 Hz. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001. Degree of protection: EN 60529:2000. Input: EN 61131-2:2007. Emitted interference: EN 61000-6-4:2001. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2001. Ambient temperature: -25 … 70 °C (-13 … 158 °F). Storage temperature: -25 … 85 °C (-13 … 185 °F). Relative humidity: 90 % , noncondensing. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 … 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 … 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 80 g. Dimensions: . Height48.5 mmWidth22.5 mmLength99.6 mm: . Height: 48.5 mm. Width: 22.5 mm. Length: 99.6 mm. Mounting: DIN mounting rail
Specification
General specifications
| Node type | A/B node |
|---|---|
| AS-Interface specification | V2.1 |
| Required gateway specification | ≥ V2.0 |
| Profile | S-0.A.0 |
| IO code0ID codeAID1 code7ID2 code0 | |
| IO code | 0 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 0 |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0 |
|---|---|
| LED PWR | AS-Interface voltage; LED green |
| LED IN | switching state (input); 4 LED yellow |
Electrical specifications
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
|---|---|
| Rated operating current | ≤ 25 mA (without sensors) / max. 60 mA |
| Protection class | III |
| Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts |
|---|---|
| Supply | from AS-Interface |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA | |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
| Signal delay | < 2 ms (input/AS-Interface) |
| Signal frequency | ≤ 250 Hz |
Directive conformity
| Electromagnetic compatibility | |
|---|---|
| Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 | |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2001 EN 61000-6-4:2001 |
Standard conformity
| Degree of protection | EN 60529:2000 |
|---|---|
| Input | EN 61131-2:2007 |
| Emitted interference | EN 61000-6-4:2001 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2001 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
|---|---|
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 90 % , noncondensing |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 |
|---|---|
| Connection | removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
| Material | |
| HousingPA 66-FR | |
| Housing | PA 66-FR |
| Mass | 80 g |
| Dimensions | |
| Height48.5 mmWidth22.5 mmLength99.6 mm | |
| Height | 48.5 mm |
| Width | 22.5 mm |
| Length | 99.6 mm |
| Mounting | DIN mounting rail |