Fast delivery within 72 Hours
Pepperl Fuchs VAN-24DC-K28
AS-Interface power supply. AS-Interface power supply, data decoupling, 4 A, 24 V DC input voltage. UL File Number: E223176. MTBF: 100 a. LED AS-i ok: LED green:ON: AS-Interface voltage OKOFF: overload…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
AS-Interface power supply. AS-Interface power supply, data decoupling, 4 A, 24 V DC input voltage. UL File Number: E223176. MTBF: 100 a. LED AS-i ok: LED green:ON: AS-Interface voltage OKOFF: overload or no supply voltage. Fusing: T10A HBC (not accessible). Rated operating voltage: 24 VDC18 … 32,4 VDC (continuous operation)14 … 18 VDC (max. 60 s or with derating)max. 36 VDC (max. continuous input voltage with no damage to the DC/DC converter). Rated operating current: 5.6 A at 24 VDC. Efficiency: typ. 90.5 % (24 VDC, 4 A). Short-circuit protection/overload: > 5 A 4.4 A. Voltage: 30.55 VDC ±3 % fixed setting. Current: 4 A. Residual ripple: < 50 mVSS (500 kHz bandwidth, 50 Ω measurement, with resistive load). Voltage limitation: max. 36 V. Directive conformity: . EMC Directive 2004/108/ECEN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001: . EMC Directive 2004/108/EC: EN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001. Standard conformity: . Noise immunityEN 61000-6-2:2005Emitted interferenceEN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009Galvanic isolationIEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV)Degree of protectionIEC 60529:2001Pollution degreeEN 60950-1:2006Shock and impact resistanceEN 60068-2-27:1995Vibration resistanceEN 60068-2-6:2008: . Noise immunity: EN 61000-6-2:2005. Emitted interference: EN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009. Galvanic isolation: IEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV). Degree of protection: IEC 60529:2001. Pollution degree: EN 60950-1:2006. Shock and impact resistance: EN 60068-2-27:1995. Vibration resistance: EN 60068-2-6:2008. Ambient temperature: -25 … 70 °C (-13 … 158 °F) note derating. Storage temperature: -40 … 85 °C (-40 … 185 °F). Shock and impact resistance: 30g/6 ms20g/11 ms. Vibration resistance: Sine 2 – 17.8 Hz: ± 1.6 mm Sine 17.8 … 500 Hz : 2 g. Pollution degree: 2. Degree of protection: IP20. Protection class: 1 (IEC 60536); Protective conductor connection necessary. Connection: Connection terminals, max. conductor cross-section Flexible cable: 0.5 … 4 mm2Rigid cable: 0.5 … 6 mm2Stripping length 7 mm. Mass: approx. 500 g. Dimensions: . Height124 mmWidth40 mmLength102 mm: . Height: 124 mm. Width: 40 mm. Length: 102 mm. Mounting: DIN mounting rail
Specification
General specifications
| UL File Number | E223176 |
|---|---|
| MTBF | 100 a |
Indicators/operating means
| LED AS-i ok | LED green:ON: AS-Interface voltage OKOFF: overload or no supply voltage |
|---|
Electrical specifications
| Fusing | T10A HBC (not accessible) |
|---|---|
| Rated operating voltage | 24 VDC18 ... 32,4 VDC (continuous operation)14 ... 18 VDC (max. 60 s or with derating)max. 36 VDC (max. continuous input voltage with no damage to the DC/DC converter) |
| Rated operating current | 5.6 A at 24 VDC |
| Efficiency | typ. 90.5 % (24 VDC, 4 A) |
Output
| Short-circuit protection/overload | > 5 A< 9 A |
|---|---|
| Current limit | > 4.4 A |
| Voltage | 30.55 VDC ±3 % fixed setting |
| Current | 4 A |
| Residual ripple | < 50 mVSS (500 kHz bandwidth, 50 Ω measurement, with resistive load) |
| Voltage limitation | max. 36 V |
Compliance with standards and directives
| Directive conformity | |
|---|---|
| EMC Directive 2004/108/ECEN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001 | |
| EMC Directive 2004/108/EC | EN 55022:2006, EN 55011:2009 Class BEN 61000-6-3:2001 , EN 61204-3:2001 |
| Standard conformity | |
| Noise immunityEN 61000-6-2:2005Emitted interferenceEN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009Galvanic isolationIEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV)Degree of protectionIEC 60529:2001Pollution degreeEN 60950-1:2006Shock and impact resistanceEN 60068-2-27:1995Vibration resistanceEN 60068-2-6:2008 | |
| Noise immunity | EN 61000-6-2:2005 |
| Emitted interference | EN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009 |
| Galvanic isolation | IEC 60364-4-41:2005 (PELV)IEC 60950:1999 (SELV) |
| Degree of protection | IEC 60529:2001 |
| Pollution degree | EN 60950-1:2006 |
| Shock and impact resistance | EN 60068-2-27:1995 |
| Vibration resistance | EN 60068-2-6:2008 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) note derating |
|---|---|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Shock and impact resistance | 30g/6 ms20g/11 ms |
| Vibration resistance | Sine 2 - 17.8 Hz: ± 1.6 mm Sine 17.8 ... 500 Hz : 2 g |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 |
|---|---|
| Protection class | 1 (IEC 60536); Protective conductor connection necessary |
| Connection | Connection terminals, max. conductor cross-section Flexible cable: 0.5 … 4 mm2Rigid cable: 0.5 … 6 mm2Stripping length 7 mm |
| Mass | approx. 500 g |
| Dimensions | |
| Height124 mmWidth40 mmLength102 mm | |
| Height | 124 mm |
| Width | 40 mm |
| Length | 102 mm |
| Mounting | DIN mounting rail |

Reviews