Fast delivery within 72 Hours
Pepperl Fuchs VAA-4E4A-KE-ZEJQ/E2L
AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs and 4 outputs. Node type: Standard node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.0. Profile: S-7….
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs and 4 outputs. Node type: Standard node. AS-Interface specification: V3.0. Required gateway specification: ≥ V2.0. Profile: S-7.0. IO code7ID code0ID1 codeFID2 codeE: . IO code: 7. ID code: 0. ID1 code: F. ID2 code: E. UL File Number: E223772. LED FAULT: Error display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs. LED INT: Internal input supply active; LED green. LED PWR: AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0. LED AUX: ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage. LED IN: switching state (input); 4 LED yellow. LED OUT: switching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption. Auxiliary voltage (input): 12 … 30 V DC PELV. Auxiliary voltage (output): 20 … 30 V DC PELV. Rated operating voltage: 26.5 … 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA (without sensors) / max. 190 mA. Protection class: III. Surge protection: UEXT, UAUX, Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT). Voltage: 21 … 31 V DC (INT). Current loading capacity: ≤ 150 mA, overload- and short-circuit protected (INT). Input current: ≤ 9 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 3 mA1 (attenuated)≥ 5 mA: . 0 (unattenuated): ≤ 3 mA. 1 (attenuated): ≥ 5 mA. Signal delay: < 1 ms (input/AS-Interface). Number/Type: 4 electronic outputs, PNP, overload and short-circuit proof. Supply: from external auxiliary voltage UAUX. Voltage: ≥ (UAUX – 0.5 V). Current: 2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap). Usage category: DC-13. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2004. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013. Ambient temperature: -25 … 60 °C (-13 … 140 °F). Storage temperature: -25 … 85 °C (-13 … 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 … 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 … 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 150 g. Dimensions: . Height99 mmWidth22.5 mmLength102 mm: . Height: 99 mm. Width: 22.5 mm. Length: 102 mm. Mounting: DIN mounting rail. Tightening torque of clamping screws: 0.5 Nm … 0.6 Nm
Specification
General specifications
| Node type | Standard node |
|---|---|
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.0 |
| Profile | S-7.0 |
| IO code7ID code0ID1 codeFID2 codeE | |
| IO code | 7 |
| ID code | 0 |
| ID1 code | F |
| ID2 code | E |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | Error display; red LEDred: communication error, i.e. address is 0red flashing: overload internal input supply, i.e. overload or lead interruption outputs |
|---|---|
| LED INT | Internal input supply active; LED green |
| LED PWR | AS-Interface voltage; green LEDgreen: voltage OKflashing green: address 0 |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/redgreen: voltage OKred: reverse voltage |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | switching state (output); 4 LED yellow/redyellow: output activered: output overload or lead interruption |
Electrical specifications
| Auxiliary voltage (input) | 12 ... 30 V DC PELV |
|---|---|
| Auxiliary voltage (output) | 20 ... 30 V DC PELV |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current | ≤ 35 mA (without sensors) / max. 190 mA |
| Protection class | III |
| Surge protection | UEXT, UAUX, Ue: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
|---|---|
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
| Voltage | 21 ... 31 V DC (INT) |
| Current loading capacity | ≤ 150 mA, overload- and short-circuit protected (INT) |
| Input current | ≤ 9 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated)≤ 3 mA1 (attenuated)≥ 5 mA | |
| 0 (unattenuated) | ≤ 3 mA |
| 1 (attenuated) | ≥ 5 mA |
| Signal delay | < 1 ms (input/AS-Interface) |
Output
| Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
|---|---|
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | 2 A per output, sum 4A (TB ≤ 40 °C) 0.5 A per output, total 2A (TB ≤ 60 °C, arranged in series without gaps)2 A per output, total 4A (TB ≤ 60 °C, arranged in series with 5 mm gap) |
| Usage category | DC-13 |
Directive conformity
| Electromagnetic compatibility | |
|---|---|
| Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 | |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 |
Standard conformity
| Degree of protection | EN 60529:2000 |
|---|---|
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2004 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
|---|---|
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 |
|---|---|
| Connection | removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
| Material | |
| HousingPA 66-FR | |
| Housing | PA 66-FR |
| Mass | 150 g |
| Dimensions | |
| Height99 mmWidth22.5 mmLength102 mm | |
| Height | 99 mm |
| Width | 22.5 mm |
| Length | 102 mm |
| Mounting | DIN mounting rail |
| Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |

Reviews