Fast delivery within 72 Hours
Pepperl Fuchs UB800-18GM40-E5-V1
Ultrasonic sensor. Single head system, Short design, 40 mm, Function indicators visible from all directions, Switching output, Series: UB-18GM40, Operating voltage: 10 … 30 V DC , ripple 10 %SS…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Ultrasonic sensor. Single head system, Short design, 40 mm, Function indicators visible from all directions, Switching output, Series: UB-18GM40, Operating voltage: 10 … 30 V DC , ripple 10 %SS, Output type: 1 switching output E5, PNP NO/NC, programmable, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 4-pin, Housing: brass, nickel-plated. Sensing range: 50 … 800 mm. Adjustment range: 70 … 800 mm. Dead band: 0 … 50 mm. Standard target plate: 100 mm x 100 mm. Transducer frequency: approx. 255 kHz. Response delay: approx. 100 ms. LED green: Power on. LED yellow: indication of the switching stateflashing: program function object detected. LED red: solid red: Errorred, flashing: program function, object not detected. Operating voltage: 10 … 30 V DC , ripple 10 %SS. No-load supply current: ≤ 20 mA. Input type: 1 program inputoperating distance 1: -UB … +1 V, operating distance 2: +6 V … +UB input impedance: > 4,7 kΩ program pulse: ≥ 1 s. Output type: 1 switching output E5, PNP NO/NC, programmable. Rated operating current: 200 mA , short-circuit/overload protected. Default setting: Switch point A1: 70 mm , Switch point A2: 800 mm. Voltage drop: ≤ 3 V. Repeat accuracy: ≤ 1 %. Switching frequency: ≤ 4 Hz. Range hysteresis: 1 % of the set operating distance. Temperature influence: ± 1.5 % of full-scale value. Standard conformity: . StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019: . Standards: EN IEC 60947-5-2:2020 IEC 60947-5-2:2019. UL approval: cULus Listed, Class 2 Power Source. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 … 70 °C (-13 … 158 °F). Storage temperature: -40 … 85 °C (-40 … 185 °F). Connection type: Connector plug M12 x 1 , 4-pin. Degree of protection: IP67. Material: . Housingbrass, nickel-platedTransducerepoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT: . Housing: brass, nickel-plated. Transducer: epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT. Mass: 25 g. Dimensions: . Length40 mmDiameter18 mm: . Length: 40 mm. Diameter: 18 mm
Specification
General specifications
| Sensing range | 50 ... 800 mm |
|---|---|
| Adjustment range | 70 ... 800 mm |
| Dead band | 0 ... 50 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx. 255 kHz |
| Response delay | approx. 100 ms |
Indicators/operating means
| LED green | Power on |
|---|---|
| LED yellow | indication of the switching stateflashing: program function object detected |
| LED red | solid red: Errorred, flashing: program function, object not detected |
Electrical specifications
| Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
|---|---|
| No-load supply current | ≤ 20 mA |
Input
| Input type | 1 program inputoperating distance 1: -UB ... +1 V, operating distance 2: +6 V ... +UB input impedance: > 4,7 kΩ program pulse: ≥ 1 s |
|---|
Output
| Output type | 1 switching output E5, PNP NO/NC, programmable |
|---|---|
| Rated operating current | 200 mA , short-circuit/overload protected |
| Default setting | Switch point A1: 70 mm , Switch point A2: 800 mm |
| Voltage drop | ≤ 3 V |
| Repeat accuracy | ≤ 1 % |
| Switching frequency | ≤ 4 Hz |
| Range hysteresis | 1 % of the set operating distance |
| Temperature influence | ± 1.5 % of full-scale value |
Compliance with standards and directives
| Standard conformity | |
|---|---|
| StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019 | |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
Approvals and certificates
| UL approval | cULus Listed, Class 2 Power Source |
|---|---|
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
|---|---|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Connection type | Connector plug M12 x 1 , 4-pin |
|---|---|
| Degree of protection | IP67 |
| Material | |
| Housingbrass, nickel-platedTransducerepoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT | |
| Housing | brass, nickel-plated |
| Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
| Mass | 25 g |
| Dimensions | |
| Length40 mmDiameter18 mm | |
| Length | 40 mm |
| Diameter | 18 mm |