Fast delivery within 72 Hours
Pepperl Fuchs UB300-18GM40-I-V1
Ultrasonic sensor. Single head system, Short design, 40 mm, Function indicators visible from all directions, Analog output 4 mA … 20 mA, Series: UB-18GM40, Operating voltage: 10 … 30 V DC , ripple…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Ultrasonic sensor. Single head system, Short design, 40 mm, Function indicators visible from all directions, Analog output 4 mA … 20 mA, Series: UB-18GM40, Operating voltage: 10 … 30 V DC , ripple 10 %SS, Output type: 1 analog output 4 … 20 mA, short-circuit/overload protected, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 4-pin. Sensing range: 35 … 300 mm. Adjustment range: 50 … 300 mm. Dead band: 0 … 35 mm. Standard target plate: 100 mm x 100 mm. Transducer frequency: approx. 390 kHz. Response delay: approx. 50 ms. LED green: Power on. LED yellow: solid yellow: object in the evaluation rangeyellow, flashing: program function, object detected. LED red: solid red: Errorred, flashing: program function, object not detected. Operating voltage: 10 … 30 V DC , ripple 10 %SS. No-load supply current: ≤ 20 mA. Input type: 1 program inputlower evaluation limit A1: -UB … +1 V, upper evaluation limit A2: +4 V … +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s. Output type: 1 analog output 4 … 20 mA, short-circuit/overload protected. Default setting: evaluation limit A1: 50 mm evaluation limit A2: 300 mm. Resolution: 0.4 mm at max. sensing range. Deviation of the characteristic curve: ± 1 % of full-scale value. Repeat accuracy: ± 0.5 % of full-scale value. Load impedance: 0 … 300 Ohm. Temperature influence: ± 1.5 % of full-scale value. Standard conformity: . StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003: . Standards: EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003. UL approval: cULus Listed, Class 2 Power Source. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 … 70 °C (-13 … 158 °F). Storage temperature: -40 … 85 °C (-40 … 185 °F). Connection type: Connector plug M12 x 1 , 4-pin. Degree of protection: IP67. Material: . Housingbrass, nickel-platedTransducerepoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT: . Housing: brass, nickel-plated. Transducer: epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT. Mass: 25 g. Dimensions: . Length40 mmDiameter18 mm: . Length: 40 mm. Diameter: 18 mm
Specification
General specifications
| Sensing range | 35 ... 300 mm |
|---|---|
| Adjustment range | 50 ... 300 mm |
| Dead band | 0 ... 35 mm |
| Standard target plate | 100 mm x 100 mm |
| Transducer frequency | approx. 390 kHz |
| Response delay | approx. 50 ms |
Indicators/operating means
| LED green | Power on |
|---|---|
| LED yellow | solid yellow: object in the evaluation rangeyellow, flashing: program function, object detected |
| LED red | solid red: Errorred, flashing: program function, object not detected |
Electrical specifications
| Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
|---|---|
| No-load supply current | ≤ 20 mA |
Input
| Input type | 1 program inputlower evaluation limit A1: -UB ... +1 V, upper evaluation limit A2: +4 V ... +UB input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s |
|---|
Output
| Output type | 1 analog output 4 ... 20 mA, short-circuit/overload protected |
|---|---|
| Default setting | evaluation limit A1: 50 mm evaluation limit A2: 300 mm |
| Resolution | 0.4 mm at max. sensing range |
| Deviation of the characteristic curve | ± 1 % of full-scale value |
| Repeat accuracy | ± 0.5 % of full-scale value |
| Load impedance | 0 ... 300 Ohm |
| Temperature influence | ± 1.5 % of full-scale value |
Compliance with standards and directives
| Standard conformity | |
|---|---|
| StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
Approvals and certificates
| UL approval | cULus Listed, Class 2 Power Source |
|---|---|
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
|---|---|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications
| Connection type | Connector plug M12 x 1 , 4-pin |
|---|---|
| Degree of protection | IP67 |
| Material | |
| Housingbrass, nickel-platedTransducerepoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT | |
| Housing | brass, nickel-plated |
| Transducer | epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT |
| Mass | 25 g |
| Dimensions | |
| Length40 mmDiameter18 mm | |
| Length | 40 mm |
| Diameter | 18 mm |

Reviews
Clear filtersThere are no reviews yet.