Fast delivery within 72 Hours

Pepperl Fuchs UB1000-18GM75-E7-V15

Ultrasonic sensor. Single head system, 2 switch outputs, 3 different output functions can be set, Selectable sound lobe width, Series: UB-18GM75, Operating voltage: 10 … 30 V DC , ripple 10 %SS…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Ultrasonic sensor. Single head system, 2 switch outputs, 3 different output functions can be set, Selectable sound lobe width, Series: UB-18GM75, Operating voltage: 10 … 30 V DC , ripple 10 %SS, Output type: 2 switch outputs NPN, normally open/closed , programmable, UL approval: cULus Listed, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Connector plug M12 x 1 , 5-pin, Housing: brass, nickel-plated. Sensing range: 70 … 1000 mm. Adjustment range: 90 … 1000 mm. Dead band: 0 … 70 mm. Standard target plate: 100 mm x 100 mm. Transducer frequency: approx. 255 kHz. Response delay: approx. 125 ms. LED yellow: indication of the switching stateflashing: program function object detected. LED red: “Error”, object uncertainin program function: No object detected. Operating voltage: 10 … 30 V DC , ripple 10 %SS. No-load supply current: ≤ 50 mA. Input type: 1 program input,operating range 1: -UB … +1 V, operating range 2: +4 V … +UB input impedance: > 4.7 kΩ; program pulse: ≥ 1 s. Output type: 2 switch outputs NPN, normally open/closed , programmable. Rated operating current: 2 x 100 mA , short-circuit/overload protected. Voltage drop: ≤ 3 V. Repeat accuracy: ≤ 1 %. Switching frequency: max. 3 Hz. Range hysteresis: 1 % of the set operating distance. Temperature influence: ± 1.5 % of full-scale value. Standard conformity: . StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019: . Standards: EN IEC 60947-5-2:2020 IEC 60947-5-2:2019. UL approval: cULus Listed, Class 2 Power Source. CCC approval: CCC approval / marking not required for products rated ≤36 V. Ambient temperature: -25 … 70 °C (-13 … 158 °F). Storage temperature: -40 … 85 °C (-40 … 185 °F). Connection type: Connector plug M12 x 1 , 5-pin. Degree of protection: IP67. Material: . Housingbrass, nickel-platedTransducerepoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT: . Housing: brass, nickel-plated. Transducer: epoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT. Mass: 60 g. Dimensions: . Length75 mmDiameter18 mm: . Length: 75 mm. Diameter: 18 mm. Output 1: Switching point: 90 mm output function: Switch point operation mode output behavior: NO contact. Output 2: Switching point: 1000 mm output function: Switch point operation mode output behavior: NO contact. Beam width: wide

Specification

General specifications

Sensing range70 ... 1000 mm
Adjustment range90 ... 1000 mm
Dead band0 ... 70 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox. 255 kHz
Response delayapprox. 125 ms

Indicators/operating means

LED yellowindication of the switching stateflashing: program function object detected
LED red"Error", object uncertainin program function: No object detected

Electrical specifications

Operating voltage10 ... 30 V DC , ripple 10 %SS
No-load supply current≤ 50 mA

Input

Input type1 program input,operating range 1: -UB ... +1 V, operating range 2: +4 V ... +UB input impedance: > 4.7 kΩ; program pulse: ≥ 1 s

Output

Output type2 switch outputs NPN, normally open/closed , programmable
Rated operating current2 x 100 mA , short-circuit/overload protected
Voltage drop≤ 3 V
Repeat accuracy≤ 1 %
Switching frequencymax. 3 Hz
Range hysteresis1 % of the set operating distance
Temperature influence± 1.5 % of full-scale value

Compliance with standards and directives

Standard conformity
StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019
StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019

Approvals and certificates

UL approvalcULus Listed, Class 2 Power Source
CCC approvalCCC approval / marking not required for products rated ≤36 V

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Connection typeConnector plug M12 x 1 , 5-pin
Degree of protectionIP67
Material
Housingbrass, nickel-platedTransducerepoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT
Housingbrass, nickel-plated
Transducerepoxy resin/hollow glass sphere mixture; foam polyurethane, cover PBT
Mass60 g
Dimensions
Length75 mmDiameter18 mm
Length75 mm
Diameter18 mm

Factory settings

Output 1Switching point: 90 mm output function: Switch point operation mode output behavior: NO contact
Output 2Switching point: 1000 mm output function: Switch point operation mode output behavior: NO contact
Beam widthwide