Fast delivery within 72 Hours
Pepperl Fuchs RLK29-55/25/116
Retroreflective sensor. Robust, compact photoelectric sensor for single-beam gate protection, Not sensitive to ambient light, even with energy saving lamps, Tamper-proof, no operating controls, Versio…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Retroreflective sensor. Robust, compact photoelectric sensor for single-beam gate protection, Not sensitive to ambient light, even with energy saving lamps, Tamper-proof, no operating controls, Version for universal voltages, Relay output, Light source: LED, Light type: modulated visible red light , 640 nm, Operating voltage: 24 … 230 V AC/DC, Switching type: light-on, Signal output: Relay, 1 alternator. Effective detection range: 0 … 12 m. Reflector distance: 0.04 … 12 m. Threshold detection range: 14 m. Reference target: H85-2 reflector. Light source: LED. Light type: modulated visible red light , 640 nm. Diameter of the light spot: approx. 35 mm at a distance of 12 m. Opening angle: ± 1 °. Ambient light limit: 90000 Lux. MTTFd: 1460 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Function indicator: LED redilluminates: when beam is freeflashes: when level falls below operating reserveoff: when beam is interrupted. Operating voltage: 24 … 230 V AC/DC. Ripple: 10 %. No-load supply current: ≤ 8.5 mA. Power consumption: 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA. Switching type: light-on. Signal output: Relay, 1 alternator. Switching voltage: 230 V AC. Switching current: max. 2 A. Switching frequency: 7 Hz. Response time: 50 ms. Product standard: EN 60947-5-2. CE conformity: yes. UL approval: cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508.. CCC approval: Certified by China Compulsory Certification (CCC). Ambient temperature: -20 … 60 °C (-4 … 140 °F). Storage temperature: -20 … 60 °C (-4 … 140 °F). Degree of protection: IP64. Connection: terminal compartment. Material: . HousingplasticOptical facePlastic pane: . Housing: plastic. Optical face: Plastic pane. Mass: 100.7 g. Dimensions: . Height88 mmWidth25.8 mmDepth65.5 mm: . Height: 88 mm. Width: 25.8 mm. Depth: 65.5 mm. Note: Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
Specification
General specifications
| Effective detection range | 0 ... 12 m |
|---|---|
| Reflector distance | 0.04 ... 12 m |
| Threshold detection range | 14 m |
| Reference target | H85-2 reflector |
| Light source | LED |
| Light type | modulated visible red light , 640 nm |
| Diameter of the light spot | approx. 35 mm at a distance of 12 m |
| Opening angle | ± 1 ° |
| Ambient light limit | 90000 Lux |
Functional safety related parameters
| MTTFd | 1460 a |
|---|---|
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Indicators/operating means
| Function indicator | LED redilluminates: when beam is freeflashes: when level falls below operating reserveoff: when beam is interrupted |
|---|
Electrical specifications
| Operating voltage | 24 ... 230 V AC/DC |
|---|---|
| Ripple | 10 % |
| No-load supply current | ≤ 8.5 mA |
| Power consumption | 0.2 W at 24 V DC , 1.8 W at 230 V AC 3 VA |
Output
| Switching type | light-on |
|---|---|
| Signal output | Relay, 1 alternator |
| Switching voltage | 230 V AC |
| Switching current | max. 2 A |
| Switching frequency | 7 Hz |
| Response time | 50 ms |
Conformity
| Product standard | EN 60947-5-2 |
|---|
Approvals and certificates
| CE conformity | yes |
|---|---|
| UL approval | cULus Listed Caution: This equipment is considered as open-type equipment. It must be mounted within an enclosure, that is suitably designed for protection against internal fire and personal injury resulting from accessibility to live parts according UL 508. |
| CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
|---|---|
| Storage temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP64 |
|---|---|
| Connection | terminal compartment |
| Material | |
| HousingplasticOptical facePlastic pane | |
| Housing | plastic |
| Optical face | Plastic pane |
| Mass | 100.7 g |
| Dimensions | |
| Height88 mmWidth25.8 mmDepth65.5 mm | |
| Height | 88 mm |
| Width | 25.8 mm |
| Depth | 65.5 mm |
| Note | Safety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |