Fast delivery within 72 Hours
Pepperl Fuchs NJ4-12GM-N-V1
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindric…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0037X, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Mb: IECEx PTB 11.0037X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 4 mm. Installation: non-flush. Assured operating distance: 0 … 3.24 mm. Reduction factor rAl: 0.4. Reduction factor rCu: 0.3. Reduction factor r304: 0.85. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 … 1500 Hz. Hysteresis: 3 %. Current consumption: . Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 3 mA. Measuring plate detected: ≤ 1 mA. Safety Integrity Level (SIL): SIL 2. MTTFd: 11774 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0037XEquipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X: . Equipment protection level Ga: IECEx PTB 11.0037X. Equipment protection level Gb: IECEx PTB 11.0037X. Equipment protection level Da: IECEx PTB 11.0037X. Equipment protection level Mb: IECEx PTB 11.0037X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2048 XEquipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X: . Equipment protection level Ga: PTB 00 ATEX 2048 X. Equipment protection level Gb: PTB 00 ATEX 2048 X. Equipment protection level Da: PTB 00 ATEX 2048 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0452: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0452. CCC approval: . Hazardous Location2020322315002255: . Hazardous Location: 2020322315002255. CML approval: on request. ANZEx: 18.3018X. KCC approval: . Hazardous Location19-AV4BO-0227: . Hazardous Location: 19-AV4BO-0227. Marine approval: DNVGL TAA00001A5. Ambient temperature: -25 … 100 °C (-13 … 212 °F). Connection type: Connector plug. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP67. Connector: . ThreadingM12 x 1Number of pins4: . Threading: M12 x 1. Number of pins: 4. Dimensions: . Length50 mmDiameter12 mm: . Length: 50 mm. Diameter: 12 mm. Scope of delivery: 2 self locking nuts in scope of delivery. Use in the hazardous area: see instruction manuals
Specification
General specifications
| Switching function | Normally closed (NC) |
|---|---|
| Output type | NAMUR |
| Rated operating distance | 4 mm |
| Installation | non-flush |
| Assured operating distance | 0 ... 3.24 mm |
| Reduction factor rAl | 0.4 |
| Reduction factor rCu | 0.3 |
| Reduction factor r304 | 0.85 |
| Output type | 2-wire |
Nominal ratings
| Nominal voltage | 8.2 V (Ri approx. 1 kΩ) |
|---|---|
| Switching frequency | 0 ... 1500 Hz |
| Hysteresis | 3 % |
| Current consumption | |
| Measuring plate not detectedmin. 3 mAMeasuring plate detected≤ 1 mA | |
| Measuring plate not detected | min. 3 mA |
| Measuring plate detected | ≤ 1 mA |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
|---|---|
| MTTFd | 11774 a |
| Mission Time (TM) | 20 a |
| Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives
| Standard conformity | |
|---|---|
| NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2 | |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| IECEx approval | |
|---|---|
| Equipment protection level GaIECEx PTB 11.0037XEquipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X | |
| Equipment protection level Ga | IECEx PTB 11.0037X |
| Equipment protection level Gb | IECEx PTB 11.0037X |
| Equipment protection level Da | IECEx PTB 11.0037X |
| Equipment protection level Mb | IECEx PTB 11.0037X |
| ATEX approval | |
| Equipment protection level GaPTB 00 ATEX 2048 XEquipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X | |
| Equipment protection level Ga | PTB 00 ATEX 2048 X |
| Equipment protection level Gb | PTB 00 ATEX 2048 X |
| Equipment protection level Da | PTB 00 ATEX 2048 X |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0452 | |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0452 |
| CCC approval | |
| Hazardous Location2020322315002255 | |
| Hazardous Location | 2020322315002255 |
| CML approval | on request |
| ANZEx | 18.3018X |
| KCC approval | |
| Hazardous Location19-AV4BO-0227 | |
| Hazardous Location | 19-AV4BO-0227 |
| Marine approval | DNVGL TAA00001A5 |
Ambient conditions
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
|---|
Mechanical specifications
| Connection type | Connector plug |
|---|---|
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Connector | |
| ThreadingM12 x 1Number of pins4 | |
| Threading | M12 x 1 |
| Number of pins | 4 |
| Dimensions | |
| Length50 mmDiameter12 mm | |
| Length | 50 mm |
| Diameter | 12 mm |
General information
| Scope of delivery | 2 self locking nuts in scope of delivery |
|---|---|
| Use in the hazardous area | see instruction manuals |

Reviews
Clear filtersThere are no reviews yet.