Pepperl Fuchs NCN3-F31K-N4

Inductive sensor. Extended temperature range, Valve position detection, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Ou…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Inductive sensor. Extended temperature range, Valve position detection, Suitable for 2:1 technology, Switching function: 2 x normally closed (NC), Output type: NAMUR, Installation: flush mountable, Output type: 2-wire, Construction type: Dual sensor, Series: Dual sensor, Suitable for 2:1 technology, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx TUN 17.0021X, Equipment protection level Gb: IECEx TUN 17.0021X, Equipment protection level Da: IECEx TUN 17.0021X. Switching function: 2 x normally closed (NC). Output type: NAMUR. Rated operating distance: 3 mm. Installation: flush mountable. Assured operating distance: 0 … 2.4 mm. Actual operating distance: 2.7 … 3.3 mm typ.. Actuating element: Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm. Reduction factor rAl: 0.5. Reduction factor rCu: 0.4. Reduction factor r304: 1. Reduction factor rSt37: 1.3. Reduction factor rBrass: 0.6. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 … 3 kHz. Hysteresis: typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Suitable for 2:1 technology: yes , Reverse polarity protection diode not required. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: ≤ 1 mA. Time delay before availability: ≤ 1.1 ms. Switching state indicator: LED, yellow. Safety Integrity Level (SIL): SIL 2. MTTFd: 1470 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx TUN 17.0021XEquipment protection level GbIECEx TUN 17.0021XEquipment protection level DaIECEx TUN 17.0021XEquipment protection level MbIECEx TUN 17.0021X: . Equipment protection level Ga: IECEx TUN 17.0021X. Equipment protection level Gb: IECEx TUN 17.0021X. Equipment protection level Da: IECEx TUN 17.0021X. Equipment protection level Mb: IECEx TUN 17.0021X. ATEX approval: . Equipment protection level GaTÜV 99 ATEX 1479 XEquipment protection level GbTÜV 99 ATEX 1479 XEquipment protection level DaTÜV 99 ATEX 1479 X: . Equipment protection level Ga: TÜV 99 ATEX 1479 X. Equipment protection level Gb: TÜV 99 ATEX 1479 X. Equipment protection level Da: TÜV 99 ATEX 1479 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0456: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0456. CCC approval: . Hazardous Location2020322315002262: . Hazardous Location: 2020322315002262. NEPSI approval: . NEPSI certificateGYJ19.1410X: . NEPSI certificate: GYJ19.1410X. Ambient temperature: -25 … 100 °C (-13 … 212 °F). Storage temperature: -40 … 100 °C (-40 … 212 °F). Connection (system side): Cage tension spring terminals Stripped length 7 mm M20 x 1.5 cable gland usable thread length 11.5 mm screw-in depth max. 11.5 mm. Core cross section (system side): Flexible: 0.2 … 1.5 mm2rigid: 0.2 … 2.5 mm2. Housing material: PBT. Sensing face: PBT. Degree of protection: IP67. Tightening torque, housing screws: 1 Nm. Tightening torque, cable gland: M20 x 1.5 ; max. 7 Nm. Dimensions: . Height35.5 mmWidth65 mmLength77.5 mm: . Height: 35.5 mm. Width: 65 mm. Length: 77.5 mm. Use in the hazardous area: see instruction manuals

Specification

General specifications

Switching function2 x normally closed (NC)
Output typeNAMUR
Rated operating distance3 mm
Installationflush mountable
Assured operating distance0 ... 2.4 mm
Actual operating distance2.7 ... 3.3 mm typ.
Actuating elementStainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm
Reduction factor rAl0.5
Reduction factor rCu0.4
Reduction factor r3041
Reduction factor rSt371.3
Reduction factor rBrass0.6
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 3 kHz
Hysteresistyp. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Suitable for 2:1 technologyyes , Reverse polarity protection diode not required
Current consumption
Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA
Measuring plate not detected≥ 3 mA
Measuring plate detected≤ 1 mA
Time delay before availability≤ 1.1 ms
Switching state indicatorLED, yellow

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
MTTFd1470 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx TUN 17.0021XEquipment protection level GbIECEx TUN 17.0021XEquipment protection level DaIECEx TUN 17.0021XEquipment protection level MbIECEx TUN 17.0021X
Equipment protection level GaIECEx TUN 17.0021X
Equipment protection level GbIECEx TUN 17.0021X
Equipment protection level DaIECEx TUN 17.0021X
Equipment protection level MbIECEx TUN 17.0021X
ATEX approval
Equipment protection level GaTÜV 99 ATEX 1479 XEquipment protection level GbTÜV 99 ATEX 1479 XEquipment protection level DaTÜV 99 ATEX 1479 X
Equipment protection level GaTÜV 99 ATEX 1479 X
Equipment protection level GbTÜV 99 ATEX 1479 X
Equipment protection level DaTÜV 99 ATEX 1479 X
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0456
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0456
CCC approval
Hazardous Location2020322315002262
Hazardous Location2020322315002262
NEPSI approval
NEPSI certificateGYJ19.1410X
NEPSI certificateGYJ19.1410X

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)

Mechanical specifications

Connection (system side)Cage tension spring terminals Stripped length 7 mm M20 x 1.5 cable gland usable thread length 11.5 mm screw-in depth max. 11.5 mm
Core cross section (system side)Flexible: 0.2 ... 1.5 mm2rigid: 0.2 ... 2.5 mm2
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Tightening torque, housing screws1 Nm
Tightening torque, cable glandM20 x 1.5 ; max. 7 Nm
Dimensions
Height35.5 mmWidth65 mmLength77.5 mm
Height35.5 mm
Width65 mm
Length77.5 mm

General information

Use in the hazardous areasee instruction manuals