Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Construction type: Rectangular, Series: Rectangular type, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0021X, Equipment protection level Gb: IECEx PTB 11.0021X, Equipment protection level Da: IECEx PTB 11.0021X, Equipment protection level Mb: IECEx PTB 11.0021X, Equipment protection level Ga: PTB 00 ATEX 2032 X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 40 mm. Installation: flush. Assured operating distance: 0 … 32 mm. Actual operating distance: 36 … 44 mm typ. 40 mm. Reduction factor rAl: 0.35. Reduction factor rCu: 0.35. Reduction factor r304: 0.8. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 … 80 Hz. Hysteresis: 0 … 5 % typ. 3 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Current consumption: . Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: ≥ 3 mA. Measuring plate detected: ≤ 1 mA. Time delay before availability: ≤ 20 ms. Switching state indicator: LED, yellow. MTTFd: 2360 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X: . Equipment protection level Ga: IECEx PTB 11.0021X. Equipment protection level Gb: IECEx PTB 11.0021X. Equipment protection level Da: IECEx PTB 11.0021X. Equipment protection level Mb: IECEx PTB 11.0021X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X: . Equipment protection level Ga: PTB 00 ATEX 2032 X. Equipment protection level Gb: PTB 00 ATEX 2032 X. Equipment protection level Da: PTB 00 ATEX 2032 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0451. CCC approval: . Hazardous Location2020322315002304: . Hazardous Location: 2020322315002304. CML approval: on request. ANZEx: 19.3001X. Ambient temperature: -25 … 100 °C (-13 … 212 °F). Storage temperature: -40 … 100 °C (-40 … 212 °F). Connection type: screw terminals. Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %. Core cross section: up to 2.5 mm2 , stripped insulation length: 7 mm. Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2: . Minimum core cross-section: without wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2. Maximum core cross-section: without wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2. Connection (system side): screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm. Housing material: PBT. Sensing face: PBT. Housing base: PBT. Degree of protection: IP66 / IP67. Mass: 427 g. Dimensions: . Height40 mmWidth83 mmLength83 mm: . Height: 40 mm. Width: 83 mm. Length: 83 mm. Use in the hazardous area: see instruction manuals

Specification

General specifications

Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance40 mm
Installationflush
Assured operating distance0 ... 32 mm
Actual operating distance36 ... 44 mm typ. 40 mm
Reduction factor rAl0.35
Reduction factor rCu0.35
Reduction factor r3040.8
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 80 Hz
Hysteresis0 ... 5 % typ. 3 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detected≥ 3 mAMeasuring plate detected≤ 1 mA
Measuring plate not detected≥ 3 mA
Measuring plate detected≤ 1 mA
Time delay before availability≤ 20 ms
Switching state indicatorLED, yellow

Functional safety related parameters

MTTFd2360 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx PTB 11.0021XEquipment protection level GbIECEx PTB 11.0021XEquipment protection level DaIECEx PTB 11.0021XEquipment protection level MbIECEx PTB 11.0021X
Equipment protection level GaIECEx PTB 11.0021X
Equipment protection level GbIECEx PTB 11.0021X
Equipment protection level DaIECEx PTB 11.0021X
Equipment protection level MbIECEx PTB 11.0021X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2032 XEquipment protection level GbPTB 00 ATEX 2032 XEquipment protection level DaPTB 00 ATEX 2032 X
Equipment protection level GaPTB 00 ATEX 2032 X
Equipment protection level GbPTB 00 ATEX 2032 X
Equipment protection level DaPTB 00 ATEX 2032 X
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0451
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0451
CCC approval
Hazardous Location2020322315002304
Hazardous Location2020322315002304
CML approvalon request
ANZEx19.3001X

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)

Mechanical specifications

Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross sectionup to 2.5 mm2 , stripped insulation length: 7 mm
Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2
Minimum core cross-sectionwithout wire end ferrules 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrules 2.5 mm2 , with connector sleeves 1.5 mm2
Connection (system side)screw terminals , M20 x 1.5 cable gland , usable thread length 10 mm , screw-in depth max. 10 mm
Housing materialPBT
Sensing facePBT
Housing basePBT
Degree of protectionIP66 / IP67
Mass427 g
Dimensions
Height40 mmWidth83 mmLength83 mm
Height40 mm
Width83 mm
Length83 mm

General information

Use in the hazardous areasee instruction manuals