Fast delivery within 72 Hours

Pepperl Fuchs NCB4-12GM40-N0-5M

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical,…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Inductive sensor. Extended temperature range, Switching function: Normally closed (NC), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Safety Integrity Level (SIL): SIL 2, Type of voltage: DC, Equipment protection level Ga: IECEx PTB 11.0037X, Equipment protection level Gb: IECEx PTB 11.0037X, Equipment protection level Da: IECEx PTB 11.0037X, Equipment protection level Mb: IECEx PTB 11.0037X. Switching function: Normally closed (NC). Output type: NAMUR. Rated operating distance: 4 mm. Installation: flush. Assured operating distance: 0 … 3.24 mm. Actual operating distance: 3.6 … 4.4 mm typ.. Reduction factor rAl: 0.41. Reduction factor rCu: 0.39. Reduction factor r304: 0.78. Output type: 2-wire. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Switching frequency: 0 … 1500 Hz. Hysteresis: 1 … 15 % typ. 5 %. Reverse polarity protection: reverse polarity protected. Short-circuit protection: yes. Current consumption: . Measuring plate not detectedmin. 2.2 mAMeasuring plate detected≤ 1 mA: . Measuring plate not detected: min. 2.2 mA. Measuring plate detected: ≤ 1 mA. Switching state indicator: all direction LED, yellow. Safety Integrity Level (SIL): SIL 2. MTTFd: 3010 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Electromagnetic compatibility: NE 21:2007. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx PTB 11.0037XEquipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X: . Equipment protection level Ga: IECEx PTB 11.0037X. Equipment protection level Gb: IECEx PTB 11.0037X. Equipment protection level Da: IECEx PTB 11.0037X. Equipment protection level Mb: IECEx PTB 11.0037X. ATEX approval: . Equipment protection level GaPTB 00 ATEX 2048 XEquipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X: . Equipment protection level Ga: PTB 00 ATEX 2048 X. Equipment protection level Gb: PTB 00 ATEX 2048 X. Equipment protection level Da: PTB 00 ATEX 2048 X. UL approval: cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0452: . Ordinary Location: E87056. Hazardous Location: E501628. Control drawing: 116-0452. CCC approval: . Hazardous Location2020322315002255: . Hazardous Location: 2020322315002255. CML approval: on request. ANZEx: 18.3018X. Ambient temperature: -25 … 100 °C (-13 … 212 °F). Storage temperature: -40 … 100 °C (-40 … 212 °F). Connection type: cable. Housing material: Stainless steel 1.4305 / AISI 303. Sensing face: PBT. Degree of protection: IP66 / IP67. Cable: . Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorblueNumber of cores2Core cross section0.34 mm2LengthL5 m: . Wire end ferrules: yes. Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Color: blue. Number of cores: 2. Core cross section: 0.34 mm2. Length: 5 m. Dimensions: . Length40 mmDiameter12 mm: . Length: 40 mm. Diameter: 12 mm. Scope of delivery: 2 self locking nuts in scope of delivery. Use in the hazardous area: see instruction manuals

Specification

General specifications

Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distance4 mm
Installationflush
Assured operating distance0 ... 3.24 mm
Actual operating distance3.6 ... 4.4 mm typ.
Reduction factor rAl0.41
Reduction factor rCu0.39
Reduction factor r3040.78
Output type2-wire

Nominal ratings

Nominal voltage8.2 V (Ri approx. 1 kΩ)
Switching frequency0 ... 1500 Hz
Hysteresis1 ... 15 % typ. 5 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionyes
Current consumption
Measuring plate not detectedmin. 2.2 mAMeasuring plate detected≤ 1 mA
Measuring plate not detectedmin. 2.2 mA
Measuring plate detected≤ 1 mA
Switching state indicatorall direction LED, yellow

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2
MTTFd3010 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999Electromagnetic compatibilityNE 21:2007StandardsEN IEC 60947-5-2
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
Electromagnetic compatibilityNE 21:2007
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx PTB 11.0037XEquipment protection level GbIECEx PTB 11.0037XEquipment protection level DaIECEx PTB 11.0037XEquipment protection level MbIECEx PTB 11.0037X
Equipment protection level GaIECEx PTB 11.0037X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
ATEX approval
Equipment protection level GaPTB 00 ATEX 2048 XEquipment protection level GbPTB 00 ATEX 2048 XEquipment protection level DaPTB 00 ATEX 2048 X
Equipment protection level GaPTB 00 ATEX 2048 X
Equipment protection level GbPTB 00 ATEX 2048 X
Equipment protection level DaPTB 00 ATEX 2048 X
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Ordinary LocationE87056Hazardous LocationE501628Control drawing116-0452
Ordinary LocationE87056
Hazardous LocationE501628
Control drawing116-0452
CCC approval
Hazardous Location2020322315002255
Hazardous Location2020322315002255
CML approvalon request
ANZEx18.3018X

Ambient conditions

Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Storage temperature-40 ... 100 °C (-40 ... 212 °F)

Mechanical specifications

Connection typecable
Housing materialStainless steel 1.4305 / AISI 303
Sensing facePBT
Degree of protectionIP66 / IP67
Cable
Wire end ferrulesyesCable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorblueNumber of cores2Core cross section0.34 mm2LengthL5 m
Wire end ferrulesyes
Cable diameter4.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Colorblue
Number of cores2
Core cross section0.34 mm2
Length5 m
Dimensions
Length40 mmDiameter12 mm
Length40 mm
Diameter12 mm

General information

Scope of delivery2 self locking nuts in scope of delivery
Use in the hazardous areasee instruction manuals

Customer Reviews