Pepperl Fuchs NBB5-18GM60-WS

Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire, Installation: flush, Output polarity: AC, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Inductive sensor. Switching function: Normally open (NO), Output type: Two-wire, Installation: flush, Output polarity: AC, Output type: 2-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: AC, Connection type: cable, Housing material: brass, nickel-plated, Degree of protection: IP67, Material: PVC. Switching function: Normally open (NO). Output type: Two-wire. Rated operating distance: 5 mm. Installation: flush. Output polarity: AC. Assured operating distance: 0 … 4.05 mm. Actual operating distance: 4.5 … 5.5 mm typ. 5 mm. Reduction factor rAl: 0.2. Reduction factor rCu: 0.2. Reduction factor r304: 0.6. Output type: 2-wire. Operating voltage: 20 … 253 V. Switching frequency: 0 … 20 Hz. Hysteresis: typ. 6 %. Reverse polarity protection: reverse polarity tolerant. Voltage drop: 50 mA); < 8 V (IL 10 x cable diameterMaterialPVCColorgreyNumber of cores3Core cross section0.34 mm2LengthL2 m: . Wire end ferrules: yes. Cable diameter: 4.6 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Color: grey. Number of cores: 3. Core cross section: 0.34 mm2. Length: 2 m. Dimensions: . Length60 mmDiameter18 mm: . Length: 60 mm. Diameter: 18 mm. Note: 1) In the temperature range below 0 °C, permissible operating voltage Ub 80…253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.

Specification

General specifications

Switching functionNormally open (NO)
Output typeTwo-wire
Rated operating distance5 mm
Installationflush
Output polarityAC
Assured operating distance0 ... 4.05 mm
Actual operating distance4.5 ... 5.5 mm typ. 5 mm
Reduction factor rAl0.2
Reduction factor rCu0.2
Reduction factor r3040.6
Output type2-wire

Nominal ratings

Operating voltage20 ... 253 V
Switching frequency0 ... 20 Hz
Hysteresistyp. 6 %
Reverse polarity protectionreverse polarity tolerant
Voltage drop< 5 V (IL > 50 mA); < 8 V (IL < 50 mA)
Momentary current(20 ms, 0.1 Hz)0 ... 1600 mA
Operating current5 ... 200 mA
Off-state current0 ... 1.7 mA typ.
Time delay before availability≤ 30 ms
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow

Compliance with standards and directives

Standard conformity
StandardsEN IEC 60947-5-2
StandardsEN IEC 60947-5-2

Approvals and certificates

UL approvalcULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)

Mechanical specifications

Connection typecable
Housing materialbrass, nickel-plated
Sensing facePBT
Degree of protectionIP67
Cable
Wire end ferrulesyesCable diameter4.6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorgreyNumber of cores3Core cross section0.34 mm2LengthL2 m
Wire end ferrulesyes
Cable diameter4.6 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Colorgrey
Number of cores3
Core cross section0.34 mm2
Length2 m
Dimensions
Length60 mmDiameter18 mm
Length60 mm
Diameter18 mm
Note1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.