Fast delivery within 72 Hours
Pepperl Fuchs IC-KP2-2HB21-2V1D
RFID evaluation unit. IDENTControl Compact RFID evaluation unit with EtherCAT interface. Number of read/write heads: max. 2alternatively 1 read/write head and 1 trigger sensor. UL File Number: E87056….
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
RFID evaluation unit. IDENTControl Compact RFID evaluation unit with EtherCAT interface. Number of read/write heads: max. 2alternatively 1 read/write head and 1 trigger sensor. UL File Number: E87056. MTBF: 80 a (Operation at +40 °C). LEDs 1, 2: Status indicator for read/write headsgreen: command at read/write head activeyellow: approx. 1 second long, if command was successfully executed. LEDs CH1, CH2: green: read head detectedred: Configuration error. LED PWR/ERR: green: power onred: Hardware fault. LED RUN: Off: initFlashing (green): pre-operationalSingle flash (green): safe-operationalOn (green): operational. Rated operating voltage: 20 … 30 V DC , PELV. Ripple: ≤ 10 % at 30 V DC. Current consumption: ≤ 4 A incl. read/write heads. Power consumption: 3.5 W Without read/write heads. Galvanic isolation: basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff. Interface type: EtherCAT (IN). Physical: Ethernet. Protocol: EtherCAT®. Transfer rate: 100 MBit/s. Interface type: EtherCAT (OUT). Physical: Ethernet. Protocol: EtherCAT®. Transfer rate: 100 MBit/s. Interface type: Diagnostic Interface. Physical: RS 232. Protocol: ASCII. Transfer rate: 38.4 kBit/s. Electromagnetic compatibility: . Directive 2014/30/EUEN 61000-6-2 EN 61000-6-4: . Directive 2014/30/EU: EN 61000-6-2 EN 61000-6-4. RoHS: . Directive 2011/65/EU (RoHS)IEC/EN 63000: . Directive 2011/65/EU (RoHS): IEC/EN 63000. Degree of protection: IEC 60529. Ambient temperature: -25 … 70 °C (-13 … 158 °F). Storage temperature: -40 … 85 °C (-40 … 185 °F). Climatic conditions: air humidity max. 96 % Salt spray resistant to EN 60068-2-52. Shock and impact resistance: Oscillation (Sine): 5 g, 10 – 1000 Hz to EN 60068-2-6Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27. Degree of protection: IP67. Connection: Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M8 connector EtherCAT: M12 connector, D-coded. Material: . Housingpowder coated aluminum: . Housing: powder coated aluminum. Installation: screw fixing. Mass: approx. 300 g. Dimensions: . Height42 mmWidth62 mmLength142 mm: . Height: 42 mm. Width: 62 mm. Length: 142 mm
Specification
General specifications
| Number of read/write heads | max. 2alternatively 1 read/write head and 1 trigger sensor |
|---|---|
| UL File Number | E87056 |
| MTBF | 80 a (Operation at +40 °C) |
Indicators/operating means
| LEDs 1, 2 | Status indicator for read/write headsgreen: command at read/write head activeyellow: approx. 1 second long, if command was successfully executed |
|---|---|
| LEDs CH1, CH2 | green: read head detectedred: Configuration error |
| LED PWR/ERR | green: power onred: Hardware fault |
| LED RUN | Off: initFlashing (green): pre-operationalSingle flash (green): safe-operationalOn (green): operational |
Electrical specifications
| Rated operating voltage | 20 ... 30 V DC , PELV |
|---|---|
| Ripple | ≤ 10 % at 30 V DC |
| Current consumption | ≤ 4 A incl. read/write heads |
| Power consumption | 3.5 W Without read/write heads |
| Galvanic isolation | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff |
Interface 1
| Interface type | EtherCAT (IN) |
|---|---|
| Physical | Ethernet |
| Protocol | EtherCAT® |
| Transfer rate | 100 MBit/s |
Interface 2
| Interface type | EtherCAT (OUT) |
|---|---|
| Physical | Ethernet |
| Protocol | EtherCAT® |
| Transfer rate | 100 MBit/s |
Interface 3
| Interface type | Diagnostic Interface |
|---|---|
| Physical | RS 232 |
| Protocol | ASCII |
| Transfer rate | 38.4 kBit/s |
Directive conformity
| Electromagnetic compatibility | |
|---|---|
| Directive 2014/30/EUEN 61000-6-2 EN 61000-6-4 | |
| Directive 2014/30/EU | EN 61000-6-2 EN 61000-6-4 |
| RoHS | |
| Directive 2011/65/EU (RoHS)IEC/EN 63000 | |
| Directive 2011/65/EU (RoHS) | IEC/EN 63000 |
Standard conformity
| Degree of protection | IEC 60529 |
|---|
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
|---|---|
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Climatic conditions | air humidity max. 96 % Salt spray resistant to EN 60068-2-52 |
| Shock and impact resistance | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
Mechanical specifications
| Degree of protection | IP67 |
|---|---|
| Connection | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M8 connector EtherCAT: M12 connector, D-coded |
| Material | |
| Housingpowder coated aluminum | |
| Housing | powder coated aluminum |
| Installation | screw fixing |
| Mass | approx. 300 g |
| Dimensions | |
| Height42 mmWidth62 mmLength142 mm | |
| Height | 42 mm |
| Width | 62 mm |
| Length | 142 mm |

Reviews