Fast delivery within 72 Hours

Pepperl Fuchs HiCTB32-HIM-RAS-SP-DI3202

Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals,…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Termination Board. System board for HIMA, HIMax, For 32-channel card X-DI 32 02 (DI), For 32 modules, Recommended modules: HiC2831 (DI), HiC2853 (DI), 24 V DC supply, Hazardous area: spring terminals, blue, Non-hazardous area: HIMA system connector, 96-pin, Non-hazardous area: spring terminals, black, Number of modules: 32, Signal type: Digital Input, Manufacturer: HIMA, Control system type: HIMax. Connection: XG2: terminals 1, 3 (+); 2, 4 (-). Nominal voltage: 24 V DC , in consideration of rated voltage of used isolators. Voltage drop: 0.9 V , voltage drop across the series diode on the termination board must be considered. Ripple: ≤ 10 %. Fusing: 4 A , in each case for 32 modules. Power dissipation: ≤ 500 mW , without modules. Reverse polarity protection: yes. Supply: Redundancy available. The supply for the isolators is decoupled, monitored and fused.. Connection: XG2: terminals 5, 6. Output type: volt-free contact. Switch behaviour: no fault: relay contact closed power supply fault: relay contact open module fault: relay contact open. Contact loading: 30 V DC, 1 A. Display elements: LED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 (industrial locations): . Directive 2014/30/EU: EN 61326-1:2013 (industrial locations). Electromagnetic compatibility: NE 21:2017For further information see system description.. Degree of protection: IEC 60529:2001. Ambient temperature: -20 … 60 °C (-4 … 140 °F). Storage temperature: -40 … 85 °C (-40 … 185 °F). Degree of protection: IP20. Connection: . Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , blackSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black: . Field side: explosion hazardous area: spring terminals , blue. Control side: non-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , black. Supply: pluggable spring terminals , black. Fault output: pluggable spring terminals , black. Core cross section: spring terminals: 0.25 … 1.5 mm2 (24 … 16 AWG). Material: housing: polycarbonate, 10 % glass fiber reinforced. Mass: approx. 1380 g. Dimensions: 432 x 200 x 163 mm (17 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly. Height200 mmWidth432 mmDepth163 mm: . Height: 200 mm. Width: 432 mm. Depth: 163 mm. Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001. EU-type examination certificate: CESI 06 ATEX 022. Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I: . Marking: II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I. Non-hazardous area: . Maximum safe voltage250 V (Attention! Um is no rated voltage.): . Maximum safe voltage: 250 V (Attention! Um is no rated voltage.). Galvanic isolation: . Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V: . Field circuit/control circuit: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000. UL approval: E106378. Control drawing116-0327: . Control drawing: 116-0327. IECEx approval: . IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I: . IECEx certificate: IECEx CES 06.0003. IECEx marking: [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specification

Supply

ConnectionXG2: terminals 1, 3 (+); 2, 4 (-)
Nominal voltage24 V DC , in consideration of rated voltage of used isolators
Voltage drop0.9 V , voltage drop across the series diode on the termination board must be considered
Ripple≤ 10 %
Fusing4 A , in each case for 32 modules
Power dissipation≤ 500 mW , without modules
Reverse polarity protectionyes

Redundancy

SupplyRedundancy available. The supply for the isolators is decoupled, monitored and fused.

Fault indication output

ConnectionXG2: terminals 5, 6
Output typevolt-free contact
Switch behaviourno fault: relay contact closed power supply fault: relay contact open module fault: relay contact open
Contact loading30 V DC, 1 A

Indicators/settings

Display elementsLED PWR1 (termination board power supply), green LEDLED PWR2 (termination board power supply), green LED LED FAULT (fault indication), red LED- LED lits: power supply fault- LED flashes: module fault LED Run, green LED- The HIMax I/O module is supplied with power and is connected to the Termination Board (FTA) via a system cable.LED Field, red LED- The HIMax I/O module detects faults in the connection between HIMax I/O module and Termination Board (FTA).

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2017For further information see system description.
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)

Mechanical specifications

Degree of protectionIP20
Connection
Field sideexplosion hazardous area: spring terminals , blueControl sidenon-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , blackSupplypluggable spring terminals , blackFault outputpluggable spring terminals , black
Field sideexplosion hazardous area: spring terminals , blue
Control sidenon-explosion hazardous area: HIMA system connector, 96-pin and spring terminals , black
Supplypluggable spring terminals , black
Fault outputpluggable spring terminals , black
Core cross sectionspring terminals: 0.25 ... 1.5 mm2 (24 ... 16 AWG)
Materialhousing: polycarbonate, 10 % glass fiber reinforced
Massapprox. 1380 g
Dimensions432 x 200 x 163 mm (17 x 7.9 x 6.42 inch) (W x H x D) , depth including module assembly
Height200 mmWidth432 mmDepth163 mm
Height200 mm
Width432 mm
Depth163 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateCESI 06 ATEX 022
Marking II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
Non-hazardous area
Maximum safe voltage250 V (Attention! Um is no rated voltage.)
Maximum safe voltage250 V (Attention! Um is no rated voltage.)
Galvanic isolation
Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Field circuit/control circuitsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 50303:2000

International approvals

UL approvalE106378
Control drawing116-0327
Control drawing116-0327
IECEx approval
IECEx certificateIECEx CES 06.0003IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I
IECEx certificateIECEx CES 06.0003
IECEx marking[Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I