Fast delivery within 72 Hours

Pepperl Fuchs HD2-DM-A

Advanced Diagnostic Module. Advanced diagnostic module, plug-in module for the fieldbus power hub, Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldC…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Advanced Diagnostic Module. Advanced diagnostic module, plug-in module for the fieldbus power hub, Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada. Design / Mounting: Motherboard based. Installation in hazardous area: Zone 2 / Div. 2. Rated voltage: 19.2 … 35 V. Rated current: 110 … 30 mA. Power dissipation: max. 2 W. Number of segments: 4. Fieldbus type: FOUNDATION Fieldbus/PROFIBUS PA. Rated voltage: 9 … 32 V. LED PRI PWR: green: on, primary bulk power supply connected. LED SEC PWR: green: on, secondary bulk power supply connected. LED Seg 1…4: yellow: bus activity; red 2 Hz flashing: alarm; red: hardware error. Fault signal: VFC alarm 1 A, 50 V DC, normally closed. DIP switch: diagnostic address 1…247, binary coded. Interface type: diagnostic bus: RS 485. Fieldbus segment/Fieldbus segment: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Fieldbus segment/Supply: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21:2011. Degree of protection: IEC 60529. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Ambient temperature: -40 … 70 °C (-40 … 158 °F). Storage temperature: -40 … 85 °C (-40 … 185 °F). Relative humidity: < 95 % non-condensing. Shock resistance: 15 g 11 ms. Vibration resistance: 1 g , 10 … 150 Hz. Pollution degree: max. 2, according to IEC 60664. Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3. Core cross section: motherboard specific. Housing material: Polycarbonate. Degree of protection: IP20. Mass: approx. 100 g. Dimensions: . Height106 mmWidth18 mmDepth128 mm: . Height: 106 mm. Width: 18 mm. Depth: 128 mm. Mounting: motherboard mounting. Mating cycles: 100. Certificate: TÜV 04 ATEX 2500 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010. FM approval: . FM certificateFM 19 US 0015 X and FM 19 CA 0011 XFM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4: . FM certificate: FM 19 US 0015 X and FM 19 CA 0011 X. FM marking: Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4. IECEx approval: . IECEx certificateIECEx TUN 13.0038XIECEx markingEx nA IIC T4 Gc: . IECEx certificate: IECEx TUN 13.0038X. IECEx marking: Ex nA IIC T4 Gc. Patents: This product may be covered by the following patent: US7,698,103. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Specification

General specifications

Design / MountingMotherboard based
Installation in hazardous areaZone 2 / Div. 2

Supply

Rated voltage19.2 ... 35 V
Rated current110 ... 30 mA
Power dissipationmax. 2 W

Fieldbus connection

Number of segments4
Fieldbus typeFOUNDATION Fieldbus/PROFIBUS PA
Rated voltage9 ... 32 V

Indicators/operating means

LED PRI PWRgreen: on, primary bulk power supply connected
LED SEC PWRgreen: on, secondary bulk power supply connected
LED Seg 1...4yellow: bus activity; red 2 Hz flashing: alarm; red: hardware error
Fault signalVFC alarm 1 A, 50 V DC, normally closed
DIP switchdiagnostic address 1...247, binary coded

Interface

Interface typediagnostic bus: RS 485

Galvanic isolation

Fieldbus segment/Fieldbus segmentfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Fieldbus segment/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 50 Veff

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Directive 2014/30/EUEN 61326-1:2013

Standard conformity

Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Core cross sectionmotherboard specific
Housing materialPolycarbonate
Degree of protectionIP20
Massapprox. 100 g
Dimensions
Height106 mmWidth18 mmDepth128 mm
Height106 mm
Width18 mm
Depth128 mm
Mountingmotherboard mounting
Mating cycles100

Data for application in connection with hazardous areas

CertificateTÜV 04 ATEX 2500 X
Marking II 3 G Ex nA IIC T4 Gc
MarkingII 3 G Ex nA IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

FM approval
FM certificateFM 19 US 0015 X and FM 19 CA 0011 XFM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4
FM certificateFM 19 US 0015 X and FM 19 CA 0011 X
FM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4
IECEx approval
IECEx certificateIECEx TUN 13.0038XIECEx markingEx nA IIC T4 Gc
IECEx certificateIECEx TUN 13.0038X
IECEx markingEx nA IIC T4 Gc

Certificates and approvals

PatentsThis product may be covered by the following patent: US7,698,103

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Pepperl Fuchs HD2-DM-A”

Your email address will not be published. Required fields are marked *