Fast delivery within 72 Hours

Pepperl Fuchs FB6215BR

Digital Output. 4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Solenoid Valve, Fi…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Digital Output. 4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm. Occupied slots: 2. Connection: backplane bus / 24 V booster via wire ends. Rated voltage: 12 V DC , only in connection with the power supplies FB92**. Input voltage range: 18.5 … 32 V DC (SELV/PELV) booster voltage. Power dissipation: 3 W. Power consumption: 0.15 W. Connection: backplane bus. Interface: manufacturer-specific bus to standard com unit. Number of channels: 4. Suitable field devices: . Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm: . Field device: Solenoid Valve. Field device [2]: audible alarm. Field device [3]: visual alarm. Connection: channel I: 9+, 10-; channel II: 11+, 12-; channel III: 13+, 14-; channel IV: 15+, 16-. Internal resistor: max. 90 Ω. Current limit: 70 mA. Open loop voltage: 16.6 V. Line fault detection: can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms). Short-circuit 15 kΩ: . Short-circuit: 15 kΩ. Response time: 10 ms (depending on bus cycle time). Watchdog: within 0.5 s the device goes in safe state, e.g. after loss of communication. Reaction time: 10 s. LED indication: LED green: supply LED red: line fault , red flashing: communication error. Coding: optional mechanical coding via front socket. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1: . Directive 2014/30/EU: EN 61326-1. Electromagnetic compatibility: NE 21. Degree of protection: IEC 60529. Environmental test: EN 60068-2-14. Shock resistance: EN 60068-2-27. Vibration resistance: EN 60068-2-6. Damaging gas: EN 60068-2-42. Relative humidity: EN 60068-2-78. Ambient temperature: -20 … 60 °C (-4 … 140 °F). Storage temperature: -25 … 85 °C (-13 … 185 °F). Relative humidity: 95 % non-condensing. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 … 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 … 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20 (module) , a separate housing is required acc. to the system description. Connection: removable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 … 1.5 mm2) or screw terminals (0.08 … 1.5 mm2). Mass: approx. 750 g. Dimensions: 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch). EU-type examination certificate: PTB 97 ATEX 1074 U. Marking II 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC: . Marking: II 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC. Output: . VoltageUo18.9 VCurrentIo286 mAPowerPo1351 mWInternal capacitanceCi2.5 nFInternal inductanceLi0 mH: Uo. Voltage: 18.9 V. Current: 286 mA. Power: 1351 mW. Internal capacitance: 2.5 nF. Internal inductance: 0 mH. Galvanic isolation: . Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V: . Output/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V. Directive conformity: . Directive 2014/34/EUEN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006: . Directive 2014/34/EU: EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006. ATEX approval: PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U. EAC approval: Russia: RU C-IT.MIII06.B.00129. Marine approval: . Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UNBureau Veritas Marine22449/B0 BV: . Lloyd Register: 15/20021. DNV GL Marine: TAA0000034. American Bureau of Shipping: T1450280/UN. Bureau Veritas Marine: 22449/B0 BV. System information: The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.. Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Specification

Slots

Occupied slots2

Supply

Connectionbackplane bus / 24 V booster via wire ends
Rated voltage12 V DC , only in connection with the power supplies FB92**
Input voltage range18.5 ... 32 V DC (SELV/PELV) booster voltage
Power dissipation3 W
Power consumption0.15 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Digital output

Number of channels4
Suitable field devices
Field deviceSolenoid ValveField device [2]audible alarmField device [3]visual alarm
Field deviceSolenoid Valve
Field device [2]audible alarm
Field device [3]visual alarm
Connectionchannel I: 9+, 10-; channel II: 11+, 12-; channel III: 13+, 14-; channel IV: 15+, 16-
Internal resistormax. 90 Ω
Current limit70 mA
Open loop voltage16.6 V
Line fault detectioncan be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms)
Short-circuit< 100 ΩOpen-circuit> 15 kΩ
Short-circuit< 100 Ω
Open-circuit> 15 kΩ
Response time10 ms (depending on bus cycle time)
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication
Reaction time10 s

Indicators/settings

LED indicationLED green: supply LED red: line fault , red flashing: communication error
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1
Directive 2014/30/EUEN 61326-1

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity95 % non-condensing
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 (module) , a separate housing is required acc. to the system description
Connectionremovable front connector with screw flange (accessory)wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 750 g
Dimensions57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch)

Data for application in connection with hazardous areas

EU-type examination certificatePTB 97 ATEX 1074 U
Marking II 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC
MarkingII 2(1) G Ex d [ia Ga] IIC Gb [exsign] II (1) D [Ex ia Da] IIIC
Output
VoltageUo18.9 VCurrentIo286 mAPowerPo1351 mWInternal capacitanceCi2.5 nFInternal inductanceLi0 mHUo
Voltage18.9 V
Current286 mA
Power1351 mW
Internal capacitance2.5 nF
Internal inductance0 mH
Galvanic isolation
Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006
Directive 2014/34/EUEN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006

International approvals

ATEX approvalPTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U
EAC approvalRussia: RU C-IT.MIII06.B.00129
Marine approval
Lloyd Register15/20021DNV GL MarineTAA0000034American Bureau of ShippingT1450280/UNBureau Veritas Marine22449/B0 BV
Lloyd Register15/20021
DNV GL MarineTAA0000034
American Bureau of ShippingT1450280/UN
Bureau Veritas Marine22449/B0 BV

General information

System informationThe module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Pepperl Fuchs FB6215BR”

Your email address will not be published. Required fields are marked *