Fast delivery within 72 Hours

Pepperl Fuchs CJ4-12GK-N

Capacitive sensor. Switching function: Normally open (NO), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindric…

Request for Quote

Shipping & Delivery

  • Courier delivery

Our courier will deliver to the specified address

5-6 Days

From €20

  • DHL Courier delivery

DHL courier will deliver to the specified address

2-3 Days

From €40

  • Warranty 1 year
  • Free 30-Day returns

Description

Capacitive sensor. Switching function: Normally open (NO), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Equipment protection level Ga: IECEx TUN 20.0014X, Equipment protection level Gb: IECEx TUN 20.0014X, Equipment protection level Da: IECEx TUN 20.0014X, Equipment protection level Ga: TÜV 03 ATEX 2003 X, Equipment protection level Gb: TÜV 03 ATEX 2003 X. Switching function: Normally open (NO). Output type: NAMUR. Rated operating distance: 4 mm. Installation: non-flush. Assured operating distance: 0 … 2.88 mm. Output type: 2-wire. Installation conditions: . A20 mmB80 mmC12 mmF70 mm: . A: 20 mm. B: 80 mm. C: 12 mm. F: 70 mm. Nominal voltage: 8.2 V (Ri approx. 1 kΩ). Operating voltage: 7 … 12 V. Switching frequency: 0 … 1 Hz. Current consumption: . Measuring plate not detected≤ 1 mAMeasuring plate detected≥ 2.4 mA: . Measuring plate not detected: ≤ 1 mA. Measuring plate detected: ≥ 2.4 mA. MTTFd: 3299 a. Mission Time (TM): 20 a. Diagnostic Coverage (DC): 0 %. Standard conformity: . NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2: . NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999. Standards: EN IEC 60947-5-2. IECEx approval: . Equipment protection level GaIECEx TUN 20.0014XEquipment protection level GbIECEx TUN 20.0014XEquipment protection level DaIECEx TUN 20.0014X: . Equipment protection level Ga: IECEx TUN 20.0014X. Equipment protection level Gb: IECEx TUN 20.0014X. Equipment protection level Da: IECEx TUN 20.0014X. ATEX approval: . Equipment protection level GaTÜV 03 ATEX 2003 XEquipment protection level GbTÜV 03 ATEX 2003 XEquipment protection level DaTÜV 03 ATEX 2003 X: . Equipment protection level Ga: TÜV 03 ATEX 2003 X. Equipment protection level Gb: TÜV 03 ATEX 2003 X. Equipment protection level Da: TÜV 03 ATEX 2003 X. FM approval: . Control drawing116-0165: . Control drawing: 116-0165. UL approval: cULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC. Ambient temperature: -25 … 70 °C (-13 … 158 °F). Connection type: cable. Housing material: PBT. Sensing face: PBT. Degree of protection: IP68. Cable: . Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.34 mm2LengthL2 m: . Cable diameter: 4.8 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Core cross section: 0.34 mm2. Length: 2 m. Dimensions: . Length60 mmDiameter12 mm: . Length: 60 mm. Diameter: 12 mm. Use in the hazardous area: see instruction manuals

Specification

General specifications

Switching functionNormally open (NO)
Output typeNAMUR
Rated operating distance4 mm
Installationnon-flush
Assured operating distance0 ... 2.88 mm
Output type2-wire

Nominal ratings

Installation conditions
A20 mmB80 mmC12 mmF70 mm
A20 mm
B80 mm
C12 mm
F70 mm
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Operating voltage7 ... 12 V
Switching frequency0 ... 1 Hz
Current consumption
Measuring plate not detected≤ 1 mAMeasuring plate detected≥ 2.4 mA
Measuring plate not detected≤ 1 mA
Measuring plate detected≥ 2.4 mA

Functional safety related parameters

MTTFd3299 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %

Compliance with standards and directives

Standard conformity
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999StandardsEN IEC 60947-5-2
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
StandardsEN IEC 60947-5-2

Approvals and certificates

IECEx approval
Equipment protection level GaIECEx TUN 20.0014XEquipment protection level GbIECEx TUN 20.0014XEquipment protection level DaIECEx TUN 20.0014X
Equipment protection level GaIECEx TUN 20.0014X
Equipment protection level GbIECEx TUN 20.0014X
Equipment protection level DaIECEx TUN 20.0014X
ATEX approval
Equipment protection level GaTÜV 03 ATEX 2003 XEquipment protection level GbTÜV 03 ATEX 2003 XEquipment protection level DaTÜV 03 ATEX 2003 X
Equipment protection level GaTÜV 03 ATEX 2003 X
Equipment protection level GbTÜV 03 ATEX 2003 X
Equipment protection level DaTÜV 03 ATEX 2003 X
FM approval
Control drawing116-0165
Control drawing116-0165
UL approvalcULus Listed Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)

Mechanical specifications

Connection typecable
Housing materialPBT
Sensing facePBT
Degree of protectionIP68
Cable
Cable diameter4.8 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCCore cross section0.34 mm2LengthL2 m
Cable diameter4.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPVC
Core cross section0.34 mm2
Length2 m
Dimensions
Length60 mmDiameter12 mm
Length60 mm
Diameter12 mm

General information

Use in the hazardous areasee instruction manuals

Customer Reviews

0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Pepperl Fuchs CJ4-12GK-N”

Your email address will not be published. Required fields are marked *