Fast delivery within 72 Hours
Pepperl Fuchs CJ10-30GK-WO
Capacitive sensor. Switching function: Normally closed (NC), Output type: Two-wire, Installation: non-flush, Output polarity: AC, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical,…
Request for Quote
Shipping & Delivery
-
Courier delivery
Our courier will deliver to the specified address
5-6 Days
From €20
-
DHL Courier delivery
DHL courier will deliver to the specified address
2-3 Days
From €40
-
Warranty 1 year
-
Free 30-Day returns
Description
Capacitive sensor. Switching function: Normally closed (NC), Output type: Two-wire, Installation: non-flush, Output polarity: AC, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 20 … 253 V AC 1), Potentiometer: sensitivity adjustment, Type of voltage: AC, Connection type: cable, Housing material: PBT, Degree of protection: IP67. Switching function: Normally closed (NC). Output type: Two-wire. Rated operating distance: 10 mm. Installation: non-flush. Output polarity: AC. Assured operating distance: 0 … 7.2 mm. Output type: 2-wire. Installation conditions: . A18 mmB10 mmC20 mmF60 mm: . A: 18 mm. B: 10 mm. C: 20 mm. F: 60 mm. Operating voltage: 20 … 253 V AC 1). Switching frequency: 0 … 10 Hz. Hysteresis: 2 … 10 % typ. 5 %. Reverse polarity protection: reverse polarity tolerant. Voltage drop at IL: . Voltage drop IL = 100 mA, switching element onUdtyp. 7 V: Ud. Voltage drop IL = 100 mA, switching element on: typ. 7 V. Momentary current(20 ms, 0.1 Hz): 0 … 1200 mA. Rated insulation voltage: 1500 V. Operating current: 5 … 200 mA. Lowest operating current: 5 mA. Off-state current: 0.7 … 1.5 mA typ.. Time delay before availability: ≤ 300 ms. Switching state indicator: LED, yellow. Potentiometer: sensitivity adjustment. Standard conformity: . StandardsEN IEC 60947-5-2: . Standards: EN IEC 60947-5-2. UL approval: cULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1. CCC approval: Certified by China Compulsory Certification (CCC). Ambient temperature: -25 … 70 °C (-13 … 158 °F). Storage temperature: -25 … 85 °C (-13 … 185 °F). Connection type: cable. Housing material: PBT. Sensing face: PBT. Degree of protection: IP67. Cable: . Wire end ferrulesyesCable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorgreyNumber of cores2Core cross section0.75 mm2LengthL2 m: . Wire end ferrules: yes. Cable diameter: 6 mm ± 0.2 mm. Bending radius: > 10 x cable diameter. Material: PVC. Color: grey. Number of cores: 2. Core cross section: 0.75 mm2. Length: 2 m. Dimensions: . Length80 mmDiameter30 mm: . Length: 80 mm. Diameter: 30 mm. Note: 1) In the temperature range below 0 °C, permissible operating voltage Ub 80…253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
Specification
General specifications
| Switching function | Normally closed (NC) |
|---|---|
| Output type | Two-wire |
| Rated operating distance | 10 mm |
| Installation | non-flush |
| Output polarity | AC |
| Assured operating distance | 0 ... 7.2 mm |
| Output type | 2-wire |
Nominal ratings
| Installation conditions | |
|---|---|
| A18 mmB10 mmC20 mmF60 mm | |
| A | 18 mm |
| B | 10 mm |
| C | 20 mm |
| F | 60 mm |
| Operating voltage | 20 ... 253 V AC 1) |
| Switching frequency | 0 ... 10 Hz |
| Hysteresis | 2 ... 10 % typ. 5 % |
| Reverse polarity protection | reverse polarity tolerant |
| Voltage drop at IL | |
| Voltage drop IL = 100 mA, switching element onUdtyp. 7 V | Ud |
| Voltage drop IL = 100 mA, switching element on | typ. 7 V |
| Momentary current(20 ms, 0.1 Hz) | 0 ... 1200 mA |
| Rated insulation voltage | 1500 V |
| Operating current | 5 ... 200 mA |
| Lowest operating current | 5 mA |
| Off-state current | 0.7 ... 1.5 mA typ. |
| Time delay before availability | ≤ 300 ms |
| Switching state indicator | LED, yellow |
Indicators/operating means
| Potentiometer | sensitivity adjustment |
|---|
Compliance with standards and directives
| Standard conformity | |
|---|---|
| StandardsEN IEC 60947-5-2 | |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates
| UL approval | cULus Listed Load Type: General Purpose Enclosure Type Rating: Type 1 |
|---|---|
| CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
|---|---|
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications
| Connection type | cable |
|---|---|
| Housing material | PBT |
| Sensing face | PBT |
| Degree of protection | IP67 |
| Cable | |
| Wire end ferrulesyesCable diameter6 mm ± 0.2 mmBending radius> 10 x cable diameterMaterialPVCColorgreyNumber of cores2Core cross section0.75 mm2LengthL2 m | |
| Wire end ferrules | yes |
| Cable diameter | 6 mm ± 0.2 mm |
| Bending radius | > 10 x cable diameter |
| Material | PVC |
| Color | grey |
| Number of cores | 2 |
| Core cross section | 0.75 mm2 |
| Length | 2 m |
| Dimensions | |
| Length80 mmDiameter30 mm | |
| Length | 80 mm |
| Diameter | 30 mm |
| Note | 1) In the temperature range below 0 °C, permissible operating voltage Ub 80...253 V Safety fuse ≤ 0.8 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |